Adaptive Loop Modulation Technique for Enhanced Transient Response in Power Factor Correction Controller

碩士 === 國立交通大學 === 電控工程研究所 === 100 === Due to the shortage of energy, high reliability and efficiency has become the focus of current green power systems. Power factor correction (PFC) can shape the input current of off-line power supplies in phase with the input AC voltage in order to increase the r...

Full description

Bibliographic Details
Main Authors: Chen,Yi-Ting, 陳怡婷
Other Authors: Chen, Ke-Horng
Format: Others
Language:en_US
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/86178958272013459143
id ndltd-TW-100NCTU5449120
record_format oai_dc
spelling ndltd-TW-100NCTU54491202016-03-28T04:20:52Z http://ndltd.ncl.edu.tw/handle/86178958272013459143 Adaptive Loop Modulation Technique for Enhanced Transient Response in Power Factor Correction Controller 具動態迴路調變技術應用於改善暫態響應之功率因素校正器 Chen,Yi-Ting 陳怡婷 碩士 國立交通大學 電控工程研究所 100 Due to the shortage of energy, high reliability and efficiency has become the focus of current green power systems. Power factor correction (PFC) can shape the input current of off-line power supplies in phase with the input AC voltage in order to increase the real power available from the AC source. Reliability of the Power Factor Correction (PFC) system is improved by fast transient response using the proposed adaptive loop modulation (ALM). Low bandwidth of less than 20 Hz that rejects AC source of 60/120 Hz coupling deteriorated system reliability in case of output load variation. The proposed ALM can automatically adjust bandwidth to rapidly increase or decrease inductor current in order to shorten transient response time. In steady state, system stability can be guaranteed by low-frequency compensation pole without being affected by ALM. The test circuit fabricated in TSMC 500V UHV LDMOS process demonstrated the performance of the highly-integrated PFC controller with the proposed ALM. Experimental results showed that the PFC system with ALM has high PF of 99%, high efficiency of 95%, and high power driving capability of about 90W. The improvement in transient response is faster than conventional PFC design with output load variation from 90 to 20W and vice versa Chen, Ke-Horng 陳科宏 2012 學位論文 ; thesis 47 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 碩士 === 國立交通大學 === 電控工程研究所 === 100 === Due to the shortage of energy, high reliability and efficiency has become the focus of current green power systems. Power factor correction (PFC) can shape the input current of off-line power supplies in phase with the input AC voltage in order to increase the real power available from the AC source. Reliability of the Power Factor Correction (PFC) system is improved by fast transient response using the proposed adaptive loop modulation (ALM). Low bandwidth of less than 20 Hz that rejects AC source of 60/120 Hz coupling deteriorated system reliability in case of output load variation. The proposed ALM can automatically adjust bandwidth to rapidly increase or decrease inductor current in order to shorten transient response time. In steady state, system stability can be guaranteed by low-frequency compensation pole without being affected by ALM. The test circuit fabricated in TSMC 500V UHV LDMOS process demonstrated the performance of the highly-integrated PFC controller with the proposed ALM. Experimental results showed that the PFC system with ALM has high PF of 99%, high efficiency of 95%, and high power driving capability of about 90W. The improvement in transient response is faster than conventional PFC design with output load variation from 90 to 20W and vice versa
author2 Chen, Ke-Horng
author_facet Chen, Ke-Horng
Chen,Yi-Ting
陳怡婷
author Chen,Yi-Ting
陳怡婷
spellingShingle Chen,Yi-Ting
陳怡婷
Adaptive Loop Modulation Technique for Enhanced Transient Response in Power Factor Correction Controller
author_sort Chen,Yi-Ting
title Adaptive Loop Modulation Technique for Enhanced Transient Response in Power Factor Correction Controller
title_short Adaptive Loop Modulation Technique for Enhanced Transient Response in Power Factor Correction Controller
title_full Adaptive Loop Modulation Technique for Enhanced Transient Response in Power Factor Correction Controller
title_fullStr Adaptive Loop Modulation Technique for Enhanced Transient Response in Power Factor Correction Controller
title_full_unstemmed Adaptive Loop Modulation Technique for Enhanced Transient Response in Power Factor Correction Controller
title_sort adaptive loop modulation technique for enhanced transient response in power factor correction controller
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/86178958272013459143
work_keys_str_mv AT chenyiting adaptiveloopmodulationtechniqueforenhancedtransientresponseinpowerfactorcorrectioncontroller
AT chényítíng adaptiveloopmodulationtechniqueforenhancedtransientresponseinpowerfactorcorrectioncontroller
AT chenyiting jùdòngtàihuílùdiàobiànjìshùyīngyòngyúgǎishànzàntàixiǎngyīngzhīgōnglǜyīnsùxiàozhèngqì
AT chényítíng jùdòngtàihuílùdiàobiànjìshùyīngyòngyúgǎishànzàntàixiǎngyīngzhīgōnglǜyīnsùxiàozhèngqì
_version_ 1718213550739030016