The Fabrication of a Creatinine Biosensor Array

碩士 === 國立暨南國際大學 === 電機工程學系 === 100 === According to the statistics reported by the Department of Health, kidney disease is the people one of the ten leading causes of death in Taiwan. Creatinine is a risk factor for kidney disease. This study aimed to develop a new, simple, low-cost and high sen...

Full description

Bibliographic Details
Main Authors: Hong-Sheng Chen, 陳弘昇
Other Authors: Congo Tak-Shing Ching
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/49876719464221263191
id ndltd-TW-100NCNU0442102
record_format oai_dc
spelling ndltd-TW-100NCNU04421022015-10-13T21:12:10Z http://ndltd.ncl.edu.tw/handle/49876719464221263191 The Fabrication of a Creatinine Biosensor Array 矩陣型肌酸酐生物感測器之製作 Hong-Sheng Chen 陳弘昇 碩士 國立暨南國際大學 電機工程學系 100 According to the statistics reported by the Department of Health, kidney disease is the people one of the ten leading causes of death in Taiwan. Creatinine is a risk factor for kidney disease. This study aimed to develop a new, simple, low-cost and high sensitivity creatinine biosensor array (CBA) for precise determination of creatinine. The CBA on the detection of creatinine at admittance showed an excellent linear response range (50–250μM). The effects of creatinine biosensor (1x1, 1x2, and 1x3) of the CBA, SNR and sensitivity on the response of the CBA were investigated. The detection sensitivity of the CBA with 1x3 creatinine biosensor could be significantly increased (about 3-fold) as compared to that of the CBA with 1x1 creatinine biosensor because of the increase of signal to noise ratio. Finally, a simple, low-cost, high sensitivity and tiny CBA was developed being able to precisely determine plasma creatinine concentrations in both the normal physiological and pathological ranges. Congo Tak-Shing Ching 程德勝 2012 學位論文 ; thesis 52 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立暨南國際大學 === 電機工程學系 === 100 === According to the statistics reported by the Department of Health, kidney disease is the people one of the ten leading causes of death in Taiwan. Creatinine is a risk factor for kidney disease. This study aimed to develop a new, simple, low-cost and high sensitivity creatinine biosensor array (CBA) for precise determination of creatinine. The CBA on the detection of creatinine at admittance showed an excellent linear response range (50–250μM). The effects of creatinine biosensor (1x1, 1x2, and 1x3) of the CBA, SNR and sensitivity on the response of the CBA were investigated. The detection sensitivity of the CBA with 1x3 creatinine biosensor could be significantly increased (about 3-fold) as compared to that of the CBA with 1x1 creatinine biosensor because of the increase of signal to noise ratio. Finally, a simple, low-cost, high sensitivity and tiny CBA was developed being able to precisely determine plasma creatinine concentrations in both the normal physiological and pathological ranges.
author2 Congo Tak-Shing Ching
author_facet Congo Tak-Shing Ching
Hong-Sheng Chen
陳弘昇
author Hong-Sheng Chen
陳弘昇
spellingShingle Hong-Sheng Chen
陳弘昇
The Fabrication of a Creatinine Biosensor Array
author_sort Hong-Sheng Chen
title The Fabrication of a Creatinine Biosensor Array
title_short The Fabrication of a Creatinine Biosensor Array
title_full The Fabrication of a Creatinine Biosensor Array
title_fullStr The Fabrication of a Creatinine Biosensor Array
title_full_unstemmed The Fabrication of a Creatinine Biosensor Array
title_sort fabrication of a creatinine biosensor array
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/49876719464221263191
work_keys_str_mv AT hongshengchen thefabricationofacreatininebiosensorarray
AT chénhóngshēng thefabricationofacreatininebiosensorarray
AT hongshengchen jǔzhènxíngjīsuāngānshēngwùgǎncèqìzhīzhìzuò
AT chénhóngshēng jǔzhènxíngjīsuāngānshēngwùgǎncèqìzhīzhìzuò
AT hongshengchen fabricationofacreatininebiosensorarray
AT chénhóngshēng fabricationofacreatininebiosensorarray
_version_ 1718057542686343168