Development of Design and Maintenance Policies for Protective Systems with Time-Varying Failure Rates

碩士 === 國立成功大學 === 化學工程學系碩博士班 === 100 === In order to mitigate the detrimental outcomes of accidents in the modern chemical plants, it is a common practice to install protective systems on processes operated under hazardous conditions. Since any failure should be treated as a random event, the corres...

Full description

Bibliographic Details
Main Authors: EdwinWibisono, 禤得逸
Other Authors: Chuei-Tin Chang
Format: Others
Language:en_US
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/04145430405584689286
id ndltd-TW-100NCKU5063103
record_format oai_dc
spelling ndltd-TW-100NCKU50631032015-10-13T21:38:02Z http://ndltd.ncl.edu.tw/handle/04145430405584689286 Development of Design and Maintenance Policies for Protective Systems with Time-Varying Failure Rates 考慮時變故障率的保護系統設計和維護策略之發展 EdwinWibisono 禤得逸 碩士 國立成功大學 化學工程學系碩博士班 100 In order to mitigate the detrimental outcomes of accidents in the modern chemical plants, it is a common practice to install protective systems on processes operated under hazardous conditions. Since any failure should be treated as a random event, the corresponding safety function must function properly at all time. The system structure and its maintenance policy are the two key features that must be considered to ensure the availability of the protective system. A complete protection system can be divided into two parts, i.e., the alarm subsystem and shutdown subsystem. The former is facilitated by one or more independent sensors. Based on online sensor signals, a hardwired logic is often followed to determine whether or not an alarm should be set off. The latter subsystem usually consists of one or more solenoid valve or power switches. In response to the alarm decision, these shutdown units can be either be energized or de-energized to carry out the required emergency response operation(s). Any sensor may fail safely (FS) or dangerously (FD). The normal sensor state is usually recoverable after a FS failure, while repairs or replacements must be performed to overcome the FD failures. Obviously, both types of failures must be considered in conjecturing the alarm logic. To achieve a desired availability level, a common practice in process industries is to introduce hardware redundancy. Specifically, several independent sensors are installed to simultaneously monitor the same process condition and a voting device is incorporated to determine whether or not an unsafe state is actually detected. In the present study, the spare-supported corrective maintenance policy is adopted to further enhance sensor availability. On the other hand, every shutdown unit may also experience FS and FD failures. Since the FD failures in this case are often unobervable under the normal operating conditions, a preventive maintenance strategy must be adopted to ensure availability. Specifically, such units are required to be inspected at designated intervals to identify the unrevealed malfunctions. If confirmed, the broken units should be repaired or replaced immediately. If otherwise, the normal ones should be allowed to stay online before the next inspection. The durations of inspection intervals are regarded as design parameters in this work. The purpose of this study is to develop a mathematical programming model to minimize the total expected expenditure of any multilayer multichannel protective system. In particular, the failure rate of the system is assumed to increase over time, thus the previous maintenance policies (Liang and Chang, 2008; Liao and Chang, 2010) are modified accordingly. By solving the model, the optimal configurations of sensors and shutdown units, the best corrective and preventive maintenance policies and alarm/shutdown logics could be identified. Two examples are provided in this thesis to demonstrate the feasibility and effectiveness of the proposed approach. Chuei-Tin Chang 張玨庭 2012 學位論文 ; thesis 66 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 化學工程學系碩博士班 === 100 === In order to mitigate the detrimental outcomes of accidents in the modern chemical plants, it is a common practice to install protective systems on processes operated under hazardous conditions. Since any failure should be treated as a random event, the corresponding safety function must function properly at all time. The system structure and its maintenance policy are the two key features that must be considered to ensure the availability of the protective system. A complete protection system can be divided into two parts, i.e., the alarm subsystem and shutdown subsystem. The former is facilitated by one or more independent sensors. Based on online sensor signals, a hardwired logic is often followed to determine whether or not an alarm should be set off. The latter subsystem usually consists of one or more solenoid valve or power switches. In response to the alarm decision, these shutdown units can be either be energized or de-energized to carry out the required emergency response operation(s). Any sensor may fail safely (FS) or dangerously (FD). The normal sensor state is usually recoverable after a FS failure, while repairs or replacements must be performed to overcome the FD failures. Obviously, both types of failures must be considered in conjecturing the alarm logic. To achieve a desired availability level, a common practice in process industries is to introduce hardware redundancy. Specifically, several independent sensors are installed to simultaneously monitor the same process condition and a voting device is incorporated to determine whether or not an unsafe state is actually detected. In the present study, the spare-supported corrective maintenance policy is adopted to further enhance sensor availability. On the other hand, every shutdown unit may also experience FS and FD failures. Since the FD failures in this case are often unobervable under the normal operating conditions, a preventive maintenance strategy must be adopted to ensure availability. Specifically, such units are required to be inspected at designated intervals to identify the unrevealed malfunctions. If confirmed, the broken units should be repaired or replaced immediately. If otherwise, the normal ones should be allowed to stay online before the next inspection. The durations of inspection intervals are regarded as design parameters in this work. The purpose of this study is to develop a mathematical programming model to minimize the total expected expenditure of any multilayer multichannel protective system. In particular, the failure rate of the system is assumed to increase over time, thus the previous maintenance policies (Liang and Chang, 2008; Liao and Chang, 2010) are modified accordingly. By solving the model, the optimal configurations of sensors and shutdown units, the best corrective and preventive maintenance policies and alarm/shutdown logics could be identified. Two examples are provided in this thesis to demonstrate the feasibility and effectiveness of the proposed approach.
author2 Chuei-Tin Chang
author_facet Chuei-Tin Chang
EdwinWibisono
禤得逸
author EdwinWibisono
禤得逸
spellingShingle EdwinWibisono
禤得逸
Development of Design and Maintenance Policies for Protective Systems with Time-Varying Failure Rates
author_sort EdwinWibisono
title Development of Design and Maintenance Policies for Protective Systems with Time-Varying Failure Rates
title_short Development of Design and Maintenance Policies for Protective Systems with Time-Varying Failure Rates
title_full Development of Design and Maintenance Policies for Protective Systems with Time-Varying Failure Rates
title_fullStr Development of Design and Maintenance Policies for Protective Systems with Time-Varying Failure Rates
title_full_unstemmed Development of Design and Maintenance Policies for Protective Systems with Time-Varying Failure Rates
title_sort development of design and maintenance policies for protective systems with time-varying failure rates
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/04145430405584689286
work_keys_str_mv AT edwinwibisono developmentofdesignandmaintenancepoliciesforprotectivesystemswithtimevaryingfailurerates
AT xuāndéyì developmentofdesignandmaintenancepoliciesforprotectivesystemswithtimevaryingfailurerates
AT edwinwibisono kǎolǜshíbiàngùzhànglǜdebǎohùxìtǒngshèjìhéwéihùcèlüèzhīfāzhǎn
AT xuāndéyì kǎolǜshíbiàngùzhànglǜdebǎohùxìtǒngshèjìhéwéihùcèlüèzhīfāzhǎn
_version_ 1718066651076755456