Field Measurement Investigation of Improving Indoor Air Quality by Total Heat Exchanger in an Office Building
碩士 === 國立勤益科技大學 === 冷凍空調系 === 100 === A person spends over 90% of his time in an indoor environment each day. Indoor air quality thus affects work quality and efficiency, particularly for those who work in the office for prolonged period. Poor air quality even compromises health. In specifically exp...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2012
|
Online Access: | http://ndltd.ncl.edu.tw/handle/48921207935656264986 |
id |
ndltd-TW-100NCIT5703001 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-100NCIT57030012016-05-06T04:12:11Z http://ndltd.ncl.edu.tw/handle/48921207935656264986 Field Measurement Investigation of Improving Indoor Air Quality by Total Heat Exchanger in an Office Building 辦公室使用全熱交換器改善室內空氣品質 之量測分析探討 CHIANG JUNG CHIN 江榮欽 碩士 國立勤益科技大學 冷凍空調系 100 A person spends over 90% of his time in an indoor environment each day. Indoor air quality thus affects work quality and efficiency, particularly for those who work in the office for prolonged period. Poor air quality even compromises health. In specifically expressing the government’s determination to improve indoor air quality, the President of Taiwan promulgated on November 23, 2011 the Indoor Air Quality Management Act, which has been passed at the Legislative Yuan on November 8, 2011 to be enforced one year after the promulgation. That makes Taiwan the second in the world to make laws on indoor air quality. Attempting to improve indoor air quality, this study uses the case of total heat exchanger retrofitted in the office of a firm in central Taiwan, investigating in the indoor temperature, humidity, CO2 concentration and energy consumption. With improvement on indoor air quality addressed, on-site measurement and tests were made and the effect of the use of total heat exchanger on the indoor temperature, humidity and energy consumption was explored. Results indicated that electricity consumption increased slightly after the improvement, but CO2 concentration was greatly decreased. It reveals that it is possible to improve the indoor air quality effectively by installing total heat exchanger in the office, and prevent the hazard to human health due to the inability to allow outside air in for the entire return air air-conditioning system as well. FJ Wang 王輔仁 2012 學位論文 ; thesis 69 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立勤益科技大學 === 冷凍空調系 === 100 === A person spends over 90% of his time in an indoor environment each day. Indoor air quality thus affects work quality and efficiency, particularly for those who work in the office for prolonged period. Poor air quality even compromises health. In specifically expressing the government’s determination to improve indoor air quality, the President of Taiwan promulgated on November 23, 2011 the Indoor Air Quality Management Act, which has been passed at the Legislative Yuan on November 8, 2011 to be enforced one year after the promulgation. That makes Taiwan the second in the world to make laws on indoor air quality. Attempting to improve indoor air quality, this study uses the case of total heat exchanger retrofitted in the office of a firm in central Taiwan, investigating in the indoor temperature, humidity, CO2 concentration and energy consumption. With improvement on indoor air quality addressed, on-site measurement and tests were made and the effect of the use of total heat exchanger on the indoor temperature, humidity and energy consumption was explored. Results indicated that electricity consumption increased slightly after the improvement, but CO2 concentration was greatly decreased. It reveals that it is possible to improve the indoor air quality effectively by installing total heat exchanger in the office, and prevent the hazard to human health due to the inability to allow outside air in for the entire return air air-conditioning system as well.
|
author2 |
FJ Wang |
author_facet |
FJ Wang CHIANG JUNG CHIN 江榮欽 |
author |
CHIANG JUNG CHIN 江榮欽 |
spellingShingle |
CHIANG JUNG CHIN 江榮欽 Field Measurement Investigation of Improving Indoor Air Quality by Total Heat Exchanger in an Office Building |
author_sort |
CHIANG JUNG CHIN |
title |
Field Measurement Investigation of Improving Indoor Air Quality by Total Heat Exchanger in an Office Building |
title_short |
Field Measurement Investigation of Improving Indoor Air Quality by Total Heat Exchanger in an Office Building |
title_full |
Field Measurement Investigation of Improving Indoor Air Quality by Total Heat Exchanger in an Office Building |
title_fullStr |
Field Measurement Investigation of Improving Indoor Air Quality by Total Heat Exchanger in an Office Building |
title_full_unstemmed |
Field Measurement Investigation of Improving Indoor Air Quality by Total Heat Exchanger in an Office Building |
title_sort |
field measurement investigation of improving indoor air quality by total heat exchanger in an office building |
publishDate |
2012 |
url |
http://ndltd.ncl.edu.tw/handle/48921207935656264986 |
work_keys_str_mv |
AT chiangjungchin fieldmeasurementinvestigationofimprovingindoorairqualitybytotalheatexchangerinanofficebuilding AT jiāngróngqīn fieldmeasurementinvestigationofimprovingindoorairqualitybytotalheatexchangerinanofficebuilding AT chiangjungchin bàngōngshìshǐyòngquánrèjiāohuànqìgǎishànshìnèikōngqìpǐnzhìzhīliàngcèfēnxītàntǎo AT jiāngróngqīn bàngōngshìshǐyòngquánrèjiāohuànqìgǎishànshìnèikōngqìpǐnzhìzhīliàngcèfēnxītàntǎo |
_version_ |
1718262396037890048 |