Add Thiourea for Acidic Copper System

碩士 === 明新科技大學 === 化學工程與材料科技研究所 === 100 === There were different kinds of additives used in the process of electroplating copper. The experiment focused on the effect of the electroplating procedure of copper by changing the thiourea concentration, observing the structure of the surface, rate of met...

Full description

Bibliographic Details
Main Author: 張曉筑
Other Authors: 梁 世 明
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/18954122324851127846
id ndltd-TW-100MHIT5063023
record_format oai_dc
spelling ndltd-TW-100MHIT50630232015-10-13T21:27:35Z http://ndltd.ncl.edu.tw/handle/18954122324851127846 Add Thiourea for Acidic Copper System 添加硫脲用於酸性硫酸銅系統之 張曉筑 碩士 明新科技大學 化學工程與材料科技研究所 100 There were different kinds of additives used in the process of electroplating copper. The experiment focused on the effect of the electroplating procedure of copper by changing the thiourea concentration, observing the structure of the surface, rate of metal deposition, analysis of crystal structure and the change of resistivity with the equipments of SEM, EDS, XRD and four-point prove. The reason to use additives was to improve the roughness, smoothness and sameness of the coating. The acid sulfuric acid copper was the main electroplating solution due to it’s simple composition, stability, high current rate and high efficiency.   The results showed that when the additive of sulfur urea was at 10 ppm, the structure of the specimen was denser, the coating smoother, the deposition faster, resistivity higher and so on. 梁 世 明 2011 學位論文 ; thesis 51 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 明新科技大學 === 化學工程與材料科技研究所 === 100 === There were different kinds of additives used in the process of electroplating copper. The experiment focused on the effect of the electroplating procedure of copper by changing the thiourea concentration, observing the structure of the surface, rate of metal deposition, analysis of crystal structure and the change of resistivity with the equipments of SEM, EDS, XRD and four-point prove. The reason to use additives was to improve the roughness, smoothness and sameness of the coating. The acid sulfuric acid copper was the main electroplating solution due to it’s simple composition, stability, high current rate and high efficiency.   The results showed that when the additive of sulfur urea was at 10 ppm, the structure of the specimen was denser, the coating smoother, the deposition faster, resistivity higher and so on.
author2 梁 世 明
author_facet 梁 世 明
張曉筑
author 張曉筑
spellingShingle 張曉筑
Add Thiourea for Acidic Copper System
author_sort 張曉筑
title Add Thiourea for Acidic Copper System
title_short Add Thiourea for Acidic Copper System
title_full Add Thiourea for Acidic Copper System
title_fullStr Add Thiourea for Acidic Copper System
title_full_unstemmed Add Thiourea for Acidic Copper System
title_sort add thiourea for acidic copper system
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/18954122324851127846
work_keys_str_mv AT zhāngxiǎozhù addthioureaforacidiccoppersystem
AT zhāngxiǎozhù tiānjiāliúniàoyòngyúsuānxìngliúsuāntóngxìtǒngzhī
_version_ 1718063747658940416