Three-channel Acoustic Photonics and Pressure sensing recorder

碩士 === 中原大學 === 電機工程研究所 === 100 === Pulse pressure measurement system is the main way of this study. The system is divided into the wrist measurement system and the arm measurement system, both measured real-time pulse signal base on constant pressure, at the same time used simplify recording system...

Full description

Bibliographic Details
Main Authors: Po-Ju Chiang, 江柏儒
Other Authors: Cheng-Lun Tsai
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/18093854599503193873
id ndltd-TW-100CYCU5442060
record_format oai_dc
spelling ndltd-TW-100CYCU54420602015-10-13T21:32:36Z http://ndltd.ncl.edu.tw/handle/18093854599503193873 Three-channel Acoustic Photonics and Pressure sensing recorder 聲、光、壓三通道脈搏訊號紀錄器 Po-Ju Chiang 江柏儒 碩士 中原大學 電機工程研究所 100 Pulse pressure measurement system is the main way of this study. The system is divided into the wrist measurement system and the arm measurement system, both measured real-time pulse signal base on constant pressure, at the same time used simplify recording system and infrared optic system, to retrieve the pulse acoustic signal and PPG signal synchronization. This study is to use a three-channel acoustic, photonics, pressure synchronized measurement system measure and analysis of subjects. This study used to capture three-channel synchronization of physiological signals, obtained pulse signal, PPG signal, pulse acoustic signal on the five segments of constant pressure that basis of average pressure. SI and RI can be obtained by the PPG signal, and PWV can be obtained by the PPG signal and pulse signal. In addition, used pulse acoustic changes to obtained spectrum information. Do further evaluation.by analysis these real-time parameters of the physical condition. The parameters of the statistical data be obtained in this study allows the subjects to distinguish between the two groups according to different ages. Inference that the correspondence between study parameters and cardiovascular physiology. In this study, the multi-information parameters at the same time and get the same results in different approaches. Validate of new feasibility cardiovascular indicator by integrating the three-channel signal measurement system. This also means that parameters in the analysis of the cardiovascular physiological conditions have great significance on the future study. Cheng-Lun Tsai Kang-Ping Lin 蔡正倫 林康平 2012 學位論文 ; thesis 90 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 電機工程研究所 === 100 === Pulse pressure measurement system is the main way of this study. The system is divided into the wrist measurement system and the arm measurement system, both measured real-time pulse signal base on constant pressure, at the same time used simplify recording system and infrared optic system, to retrieve the pulse acoustic signal and PPG signal synchronization. This study is to use a three-channel acoustic, photonics, pressure synchronized measurement system measure and analysis of subjects. This study used to capture three-channel synchronization of physiological signals, obtained pulse signal, PPG signal, pulse acoustic signal on the five segments of constant pressure that basis of average pressure. SI and RI can be obtained by the PPG signal, and PWV can be obtained by the PPG signal and pulse signal. In addition, used pulse acoustic changes to obtained spectrum information. Do further evaluation.by analysis these real-time parameters of the physical condition. The parameters of the statistical data be obtained in this study allows the subjects to distinguish between the two groups according to different ages. Inference that the correspondence between study parameters and cardiovascular physiology. In this study, the multi-information parameters at the same time and get the same results in different approaches. Validate of new feasibility cardiovascular indicator by integrating the three-channel signal measurement system. This also means that parameters in the analysis of the cardiovascular physiological conditions have great significance on the future study.
author2 Cheng-Lun Tsai
author_facet Cheng-Lun Tsai
Po-Ju Chiang
江柏儒
author Po-Ju Chiang
江柏儒
spellingShingle Po-Ju Chiang
江柏儒
Three-channel Acoustic Photonics and Pressure sensing recorder
author_sort Po-Ju Chiang
title Three-channel Acoustic Photonics and Pressure sensing recorder
title_short Three-channel Acoustic Photonics and Pressure sensing recorder
title_full Three-channel Acoustic Photonics and Pressure sensing recorder
title_fullStr Three-channel Acoustic Photonics and Pressure sensing recorder
title_full_unstemmed Three-channel Acoustic Photonics and Pressure sensing recorder
title_sort three-channel acoustic photonics and pressure sensing recorder
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/18093854599503193873
work_keys_str_mv AT pojuchiang threechannelacousticphotonicsandpressuresensingrecorder
AT jiāngbǎirú threechannelacousticphotonicsandpressuresensingrecorder
AT pojuchiang shēngguāngyāsāntōngdàomàibóxùnhàojìlùqì
AT jiāngbǎirú shēngguāngyāsāntōngdàomàibóxùnhàojìlùqì
_version_ 1718065463458529280