Prediction and comparison of a axial fan test results from the AMCA tunnel

碩士 === 國立雲林科技大學 === 機械工程系碩士班 === 99 === The object of this study was to investigate the tunnel axial flow fan, manufacturers to design blades for the base. Draw the same size but the blade angle of seven groups of different 3-D shape of the axial fan, and wind tunnel simulation of the overall test f...

Full description

Bibliographic Details
Main Authors: Po-I Chiu, 邱博異
Other Authors: Dr.Kee-Chiang Chung
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/97426549941903443944
id ndltd-TW-099YUNT5489005
record_format oai_dc
spelling ndltd-TW-099YUNT54890052016-04-08T04:21:50Z http://ndltd.ncl.edu.tw/handle/97426549941903443944 Prediction and comparison of a axial fan test results from the AMCA tunnel 軸流風機於AMCA風洞測試性能預測比較分析 Po-I Chiu 邱博異 碩士 國立雲林科技大學 機械工程系碩士班 99 The object of this study was to investigate the tunnel axial flow fan, manufacturers to design blades for the base. Draw the same size but the blade angle of seven groups of different 3-D shape of the axial fan, and wind tunnel simulation of the overall test flow boundary, change to a different pressure, speed of the boundary set.By a CFD simulation analysis is performed in this study with professional turbomachinery analysis software FINE/Turbo.Full multi-grid strategy and multistage Runge-Kutta are considered for computation. Analysis of the distribution of the fan the whole flow field, and prediction fan performance curve. In this study, the AMCA 210-07 standard wind tunnel apparatus is used for the verification of fan performance. In addition to large errors in wind capacity under,the test results reveal reasonable agreement with those of the numerical ones.The similar law of the speed change performance parameters of the conversion, calculated at different speeds of air flow and pressure, and comparison to fineturb simulation and calculated data. From the simulation results verify the law of similarity can be applied not only on the derivation of the formula, the derived data on the numerical simulation is quite accurate. Finally, the blade angle from a variety of different models to simulate.From the simulation results found in the top of the blade root and leaf angle, the lower the relative performance can be improved. The results and data are then taken as the reference for the optimization of turbomachinery design. Dr.Kee-Chiang Chung 鍾基強 2011 學位論文 ; thesis 80 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立雲林科技大學 === 機械工程系碩士班 === 99 === The object of this study was to investigate the tunnel axial flow fan, manufacturers to design blades for the base. Draw the same size but the blade angle of seven groups of different 3-D shape of the axial fan, and wind tunnel simulation of the overall test flow boundary, change to a different pressure, speed of the boundary set.By a CFD simulation analysis is performed in this study with professional turbomachinery analysis software FINE/Turbo.Full multi-grid strategy and multistage Runge-Kutta are considered for computation. Analysis of the distribution of the fan the whole flow field, and prediction fan performance curve. In this study, the AMCA 210-07 standard wind tunnel apparatus is used for the verification of fan performance. In addition to large errors in wind capacity under,the test results reveal reasonable agreement with those of the numerical ones.The similar law of the speed change performance parameters of the conversion, calculated at different speeds of air flow and pressure, and comparison to fineturb simulation and calculated data. From the simulation results verify the law of similarity can be applied not only on the derivation of the formula, the derived data on the numerical simulation is quite accurate. Finally, the blade angle from a variety of different models to simulate.From the simulation results found in the top of the blade root and leaf angle, the lower the relative performance can be improved. The results and data are then taken as the reference for the optimization of turbomachinery design.
author2 Dr.Kee-Chiang Chung
author_facet Dr.Kee-Chiang Chung
Po-I Chiu
邱博異
author Po-I Chiu
邱博異
spellingShingle Po-I Chiu
邱博異
Prediction and comparison of a axial fan test results from the AMCA tunnel
author_sort Po-I Chiu
title Prediction and comparison of a axial fan test results from the AMCA tunnel
title_short Prediction and comparison of a axial fan test results from the AMCA tunnel
title_full Prediction and comparison of a axial fan test results from the AMCA tunnel
title_fullStr Prediction and comparison of a axial fan test results from the AMCA tunnel
title_full_unstemmed Prediction and comparison of a axial fan test results from the AMCA tunnel
title_sort prediction and comparison of a axial fan test results from the amca tunnel
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/97426549941903443944
work_keys_str_mv AT poichiu predictionandcomparisonofaaxialfantestresultsfromtheamcatunnel
AT qiūbóyì predictionandcomparisonofaaxialfantestresultsfromtheamcatunnel
AT poichiu zhóuliúfēngjīyúamcafēngdòngcèshìxìngnéngyùcèbǐjiàofēnxī
AT qiūbóyì zhóuliúfēngjīyúamcafēngdòngcèshìxìngnéngyùcèbǐjiàofēnxī
_version_ 1718218058501193728