The Study of the Flow Field Across a Trileaflet Mechanical Heart Valve

博士 === 淡江大學 === 水資源及環境工程學系博士班 === 99 === Previous researchers indicated that the phenomenon of hemolysis and thrombosis would occur in the flow fields across the monoleaflet or bileaflet mechanical heart valves. The probable reasons of causing hemolysis and thrombosis included shear stresses in the...

Full description

Bibliographic Details
Main Authors: Chi-Pei Li, 李其霈
Other Authors: 盧博堅
Format: Others
Language:en_US
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/59343767424606603081
id ndltd-TW-099TKU05087002
record_format oai_dc
spelling ndltd-TW-099TKU050870022015-10-30T04:05:41Z http://ndltd.ncl.edu.tw/handle/59343767424606603081 The Study of the Flow Field Across a Trileaflet Mechanical Heart Valve 人工機械心瓣三葉瓣流場研究 Chi-Pei Li 李其霈 博士 淡江大學 水資源及環境工程學系博士班 99 Previous researchers indicated that the phenomenon of hemolysis and thrombosis would occur in the flow fields across the monoleaflet or bileaflet mechanical heart valves. The probable reasons of causing hemolysis and thrombosis included shear stresses in the flow fields might be large enough to damage red blood cells, and the closing velocity of the leaflet was excessively large to cause cavitation phenomenon. Cavitation bubbles exploded and produced high pressures which would damage red blood cells and platelets. However, the closure mechanism of the trileaflet valve was based on the vortices in the aortic sinus which benefited leaflets to close, and it was apparently different to that of monoleaflet or bileaflet mechanical heart valves which mainly depended on the reverse flow. Therefore, the closing velocity of the trileaflet valve was much slower and the probability of cavitation was also smaller. A pulsatile mock circulatory loop system that dynamically simulated physiologic circulation was used in this study. A St. Jude Medical 27 mm bileaflet valve and a 27mm new type trileaflet valve were used as test valves positioned in the aortic position. Flow field measurements were made with a digital particle image velocimeter. By applying LES and SGS, turbulent viscous shear stresses were quantified and evaluated whether red blood cells would be damaged or not. Furthermore, because manufacturing a new trileaflet valve would cost a lot of time and money, commercial software Fluent was also applied to run numerical simulations of these two valves in this study. The results of numerical simulations would be valid with the experiments and were expected to be useful for the development of the trileaflet valve in the future. The results of the experiments showed that although the maximum value of turbulent viscous shear stress was not large enough to cause damage to red blood cells, it still might inflict damage to platelets. Besides, the closing velocity of the trileaflet valve was obviously slower than the St. Jude Medical bileaflet valve, and this would effectively reduce occurrences of cavitation. The results of the numerical simulations showed that the flow fields were similar to that of the experiments even if it should be improved further. The results also indicated that numerical simulations could be applied to reduce the cost for development a new trileaflet valve in the future. 盧博堅 2011 學位論文 ; thesis 112 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 博士 === 淡江大學 === 水資源及環境工程學系博士班 === 99 === Previous researchers indicated that the phenomenon of hemolysis and thrombosis would occur in the flow fields across the monoleaflet or bileaflet mechanical heart valves. The probable reasons of causing hemolysis and thrombosis included shear stresses in the flow fields might be large enough to damage red blood cells, and the closing velocity of the leaflet was excessively large to cause cavitation phenomenon. Cavitation bubbles exploded and produced high pressures which would damage red blood cells and platelets. However, the closure mechanism of the trileaflet valve was based on the vortices in the aortic sinus which benefited leaflets to close, and it was apparently different to that of monoleaflet or bileaflet mechanical heart valves which mainly depended on the reverse flow. Therefore, the closing velocity of the trileaflet valve was much slower and the probability of cavitation was also smaller. A pulsatile mock circulatory loop system that dynamically simulated physiologic circulation was used in this study. A St. Jude Medical 27 mm bileaflet valve and a 27mm new type trileaflet valve were used as test valves positioned in the aortic position. Flow field measurements were made with a digital particle image velocimeter. By applying LES and SGS, turbulent viscous shear stresses were quantified and evaluated whether red blood cells would be damaged or not. Furthermore, because manufacturing a new trileaflet valve would cost a lot of time and money, commercial software Fluent was also applied to run numerical simulations of these two valves in this study. The results of numerical simulations would be valid with the experiments and were expected to be useful for the development of the trileaflet valve in the future. The results of the experiments showed that although the maximum value of turbulent viscous shear stress was not large enough to cause damage to red blood cells, it still might inflict damage to platelets. Besides, the closing velocity of the trileaflet valve was obviously slower than the St. Jude Medical bileaflet valve, and this would effectively reduce occurrences of cavitation. The results of the numerical simulations showed that the flow fields were similar to that of the experiments even if it should be improved further. The results also indicated that numerical simulations could be applied to reduce the cost for development a new trileaflet valve in the future.
author2 盧博堅
author_facet 盧博堅
Chi-Pei Li
李其霈
author Chi-Pei Li
李其霈
spellingShingle Chi-Pei Li
李其霈
The Study of the Flow Field Across a Trileaflet Mechanical Heart Valve
author_sort Chi-Pei Li
title The Study of the Flow Field Across a Trileaflet Mechanical Heart Valve
title_short The Study of the Flow Field Across a Trileaflet Mechanical Heart Valve
title_full The Study of the Flow Field Across a Trileaflet Mechanical Heart Valve
title_fullStr The Study of the Flow Field Across a Trileaflet Mechanical Heart Valve
title_full_unstemmed The Study of the Flow Field Across a Trileaflet Mechanical Heart Valve
title_sort study of the flow field across a trileaflet mechanical heart valve
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/59343767424606603081
work_keys_str_mv AT chipeili thestudyoftheflowfieldacrossatrileafletmechanicalheartvalve
AT lǐqípèi thestudyoftheflowfieldacrossatrileafletmechanicalheartvalve
AT chipeili réngōngjīxièxīnbànsānyèbànliúchǎngyánjiū
AT lǐqípèi réngōngjīxièxīnbànsānyèbànliúchǎngyánjiū
AT chipeili studyoftheflowfieldacrossatrileafletmechanicalheartvalve
AT lǐqípèi studyoftheflowfieldacrossatrileafletmechanicalheartvalve
_version_ 1718116731744944128