Design of Constant Warm Water Temperature in Water Drinking System

碩士 === 國立臺北科技大學 === 製造科技研究所 === 99 === The thesis of drinking constant warm water temperature control system, by experiments and EES simulation software validation. The heat transfer experiment of this system in case of uncontrolled flow, Th,out (hot side outlet temperature ) is equivalent to the wa...

Full description

Bibliographic Details
Main Authors: Shih-Hua Chen, 陳仕樺
Other Authors: 王金樹
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/es4sjw
id ndltd-TW-099TIT05621058
record_format oai_dc
spelling ndltd-TW-099TIT056210582019-05-15T20:42:29Z http://ndltd.ncl.edu.tw/handle/es4sjw Design of Constant Warm Water Temperature in Water Drinking System 飲水機溫水系統恆溫之設計 Shih-Hua Chen 陳仕樺 碩士 國立臺北科技大學 製造科技研究所 99 The thesis of drinking constant warm water temperature control system, by experiments and EES simulation software validation. The heat transfer experiment of this system in case of uncontrolled flow, Th,out (hot side outlet temperature ) is equivalent to the warm water of about 40 ℃, the system response to rapid heat transfer and the reaction time of about 2 to 3 seconds to reach temperature equilibrium. Compared to the old design system, the design system at uncontrolled flow situation is better; B(cold)side of the change in flow rate of heat transfer experiments, that this system can be critical control flow 13.6L/min, the flow above the critical control flow of Th,out temperature is lower than 45 ℃, this flow area is called controlled areas. When the flow is lower than the critical control flow, the temperature rising quickly and more difficult to control, so this area is not controlled zone. By experiments, B-side mass flow rate must be greater than A (hot) side of more than 2 times. By simulation, Th,out of the average temperature error of about 2.20%. Tc,out ( cold side of the outlet temperature) temperature error of about 3.30%. Overall, the average error on both sides about 5% . Simulated B-side (2 L / min ~ 20 L / min) flow changes. B-side flow 14L/min above, the resulting Th,out temperature is about 45 ℃ following controlled area. In the future, the use of electronic flow control valve with a program more precise control over the warm water temperature control, while increasing the memory model set to appropriate the memory of consumers drink warm water temperature, as a basis for flow control; the concept of program-controlled water system programming devices to save energy and hope to study the need of constant temperature. 王金樹 2011 學位論文 ; thesis 85 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 製造科技研究所 === 99 === The thesis of drinking constant warm water temperature control system, by experiments and EES simulation software validation. The heat transfer experiment of this system in case of uncontrolled flow, Th,out (hot side outlet temperature ) is equivalent to the warm water of about 40 ℃, the system response to rapid heat transfer and the reaction time of about 2 to 3 seconds to reach temperature equilibrium. Compared to the old design system, the design system at uncontrolled flow situation is better; B(cold)side of the change in flow rate of heat transfer experiments, that this system can be critical control flow 13.6L/min, the flow above the critical control flow of Th,out temperature is lower than 45 ℃, this flow area is called controlled areas. When the flow is lower than the critical control flow, the temperature rising quickly and more difficult to control, so this area is not controlled zone. By experiments, B-side mass flow rate must be greater than A (hot) side of more than 2 times. By simulation, Th,out of the average temperature error of about 2.20%. Tc,out ( cold side of the outlet temperature) temperature error of about 3.30%. Overall, the average error on both sides about 5% . Simulated B-side (2 L / min ~ 20 L / min) flow changes. B-side flow 14L/min above, the resulting Th,out temperature is about 45 ℃ following controlled area. In the future, the use of electronic flow control valve with a program more precise control over the warm water temperature control, while increasing the memory model set to appropriate the memory of consumers drink warm water temperature, as a basis for flow control; the concept of program-controlled water system programming devices to save energy and hope to study the need of constant temperature.
author2 王金樹
author_facet 王金樹
Shih-Hua Chen
陳仕樺
author Shih-Hua Chen
陳仕樺
spellingShingle Shih-Hua Chen
陳仕樺
Design of Constant Warm Water Temperature in Water Drinking System
author_sort Shih-Hua Chen
title Design of Constant Warm Water Temperature in Water Drinking System
title_short Design of Constant Warm Water Temperature in Water Drinking System
title_full Design of Constant Warm Water Temperature in Water Drinking System
title_fullStr Design of Constant Warm Water Temperature in Water Drinking System
title_full_unstemmed Design of Constant Warm Water Temperature in Water Drinking System
title_sort design of constant warm water temperature in water drinking system
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/es4sjw
work_keys_str_mv AT shihhuachen designofconstantwarmwatertemperatureinwaterdrinkingsystem
AT chénshìhuà designofconstantwarmwatertemperatureinwaterdrinkingsystem
AT shihhuachen yǐnshuǐjīwēnshuǐxìtǒnghéngwēnzhīshèjì
AT chénshìhuà yǐnshuǐjīwēnshuǐxìtǒnghéngwēnzhīshèjì
_version_ 1719103708625633280