Study a Study and Intercomparison of Radiation Measurement Characteristics for OSLD and TLD-LiF
碩士 === 慈濟技術學院 === 放射醫學科學研究所 === 101 === Thermoluminescent dosimeters(TLD) have been widely used in personal, environmental and medical dosimetry for several decades. Owing to the progress of crystalized techniques, a new luminescent material of aluminum oxide doped with carbon (Al2O3:C) was develo...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2012
|
Online Access: | http://ndltd.ncl.edu.tw/handle/97172556310155380416 |
id |
ndltd-TW-099TCCN0605007 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099TCCN06050072016-12-19T04:14:33Z http://ndltd.ncl.edu.tw/handle/97172556310155380416 Study a Study and Intercomparison of Radiation Measurement Characteristics for OSLD and TLD-LiF 光激發光劑量計與氟化鋰熱發光劑量計輻射偵測特性之研究比較 Tzu-Ling Kao 高紫綾 碩士 慈濟技術學院 放射醫學科學研究所 101 Thermoluminescent dosimeters(TLD) have been widely used in personal, environmental and medical dosimetry for several decades. Owing to the progress of crystalized techniques, a new luminescent material of aluminum oxide doped with carbon (Al2O3:C) was developed successfully by LandauerInc. in 1996. The optically stimulated luminescent dosimeter(OSLD)possesses several advantages such as stimulated by light, fast readout, wide dose range of detectable, high sensitivity and re-estimation of radiation. This research studied and compared the radiation detection characteristics of InLight nanoDotTM OSLD and TLD-LiF:Mg.Cu,P (TLD-100H). The radiation characteristics studied in this research include batch variance, reproducibility, linearity of radiation dose and stimulated light, photon energy dependence, angular dependence and fading effect etc.. The results of this researchrevealed that OSLD possesses better radiation characteristics in batch variance. The response reproducibility of OSLD is better than that of TLD-100H. The linearity of both OSLD and TLD-100H to radiation dose is excellent. The photon energy dependence of OSLD is higher than that of TLD-100H. OSLD has better angular dependence than that of TLD-100H. The fading of OSLD and TLD-100H are insignificant within 30 days. This study shows that OSLD possessed excellent radiation detection characteristics as compared with that of TLD-100H. OSLD will be one of the most attractive radiation dosimeter in the application of personal, environmental and medical radiation measurement. Shann-Horng Yeh 葉善宏 2012 學位論文 ; thesis 91 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 慈濟技術學院 === 放射醫學科學研究所 === 101 === Thermoluminescent dosimeters(TLD) have been widely used in personal, environmental and medical dosimetry for several decades. Owing to the progress of crystalized techniques, a new luminescent material of aluminum oxide doped with carbon (Al2O3:C) was developed successfully by LandauerInc. in 1996. The optically stimulated luminescent dosimeter(OSLD)possesses several advantages such as stimulated by light, fast readout, wide dose range of detectable, high sensitivity and re-estimation of radiation. This research studied and compared the radiation detection characteristics of InLight nanoDotTM OSLD and TLD-LiF:Mg.Cu,P (TLD-100H). The radiation characteristics studied in this research include batch variance, reproducibility, linearity of radiation dose and stimulated light, photon energy dependence, angular dependence and fading effect etc..
The results of this researchrevealed that OSLD possesses better radiation characteristics in batch variance. The response reproducibility of OSLD is better than that of TLD-100H. The linearity of both OSLD and TLD-100H to radiation dose is excellent. The photon energy dependence of OSLD is higher than that of TLD-100H. OSLD has better angular dependence than that of TLD-100H. The fading of OSLD and TLD-100H are insignificant within 30 days.
This study shows that OSLD possessed excellent radiation detection characteristics as compared with that of TLD-100H. OSLD will be one of the most attractive radiation dosimeter in the application of personal, environmental and medical radiation measurement.
|
author2 |
Shann-Horng Yeh |
author_facet |
Shann-Horng Yeh Tzu-Ling Kao 高紫綾 |
author |
Tzu-Ling Kao 高紫綾 |
spellingShingle |
Tzu-Ling Kao 高紫綾 Study a Study and Intercomparison of Radiation Measurement Characteristics for OSLD and TLD-LiF |
author_sort |
Tzu-Ling Kao |
title |
Study a Study and Intercomparison of Radiation Measurement Characteristics for OSLD and TLD-LiF |
title_short |
Study a Study and Intercomparison of Radiation Measurement Characteristics for OSLD and TLD-LiF |
title_full |
Study a Study and Intercomparison of Radiation Measurement Characteristics for OSLD and TLD-LiF |
title_fullStr |
Study a Study and Intercomparison of Radiation Measurement Characteristics for OSLD and TLD-LiF |
title_full_unstemmed |
Study a Study and Intercomparison of Radiation Measurement Characteristics for OSLD and TLD-LiF |
title_sort |
study a study and intercomparison of radiation measurement characteristics for osld and tld-lif |
publishDate |
2012 |
url |
http://ndltd.ncl.edu.tw/handle/97172556310155380416 |
work_keys_str_mv |
AT tzulingkao studyastudyandintercomparisonofradiationmeasurementcharacteristicsforosldandtldlif AT gāozǐlíng studyastudyandintercomparisonofradiationmeasurementcharacteristicsforosldandtldlif AT tzulingkao guāngjīfāguāngjìliàngjìyǔfúhuàlǐrèfāguāngjìliàngjìfúshèzhēncètèxìngzhīyánjiūbǐjiào AT gāozǐlíng guāngjīfāguāngjìliàngjìyǔfúhuàlǐrèfāguāngjìliàngjìfúshèzhēncètèxìngzhīyánjiūbǐjiào |
_version_ |
1718400923610382336 |