Experimental Study of A Full-Scale Vibration Isolated Mechanical/Electrical Equipment
碩士 === 國立臺灣科技大學 === 營建工程系 === 99 === The seismic performance of a structure depends both on the performances of structure and nonstructural components. In recent years, it is not uncommon for the damages of electrical/mechanical systems during earthquakes, which has often led to the partial or compl...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2011
|
Online Access: | http://ndltd.ncl.edu.tw/handle/gzr49b |
id |
ndltd-TW-099NTUS5512027 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099NTUS55120272019-05-15T20:42:06Z http://ndltd.ncl.edu.tw/handle/gzr49b Experimental Study of A Full-Scale Vibration Isolated Mechanical/Electrical Equipment 含隔振裝置之足尺機電設備試驗研究 JING-WEN JENG 鄭景文 碩士 國立臺灣科技大學 營建工程系 99 The seismic performance of a structure depends both on the performances of structure and nonstructural components. In recent years, it is not uncommon for the damages of electrical/mechanical systems during earthquakes, which has often led to the partial or complete loss of the function of building structures. It is therefore the aim of this study to evaluate the seismic resistance of an emergency power generator isolated by a spring vibration isolation system which has been commonly used for the electrical/mechanical system in structures to minimize the transmission of vibration of the operating electrical/mechanical system to the floor system. Experimental study including the cyclic loading tests and shaking table tests has been conducted for a full scale power generator supported by four sets of spring vibration isolators (YS-2-2400A). The hysteretic behavior and seismic responses of the isolation system is investigated. In addition the damage mechanism of the isolator is also identified. Besides, additional restrainer to enhance the seismic resistance (YS-7500EL) is added to the vibration isolation system. Same tests are performed and the test results are compared with those without the additional restrainers. Jenn-Shin Hwang 黃震興 2011 學位論文 ; thesis 121 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣科技大學 === 營建工程系 === 99 === The seismic performance of a structure depends both on the performances of structure and nonstructural components. In recent years, it is not uncommon for the damages of electrical/mechanical systems during earthquakes, which has often led to the partial or complete loss of the function of building structures. It is therefore the aim of this study to evaluate the seismic resistance of an emergency power generator isolated by a spring vibration isolation system which has been commonly used for the electrical/mechanical system in structures to minimize the transmission of vibration of the operating electrical/mechanical system to the floor system.
Experimental study including the cyclic loading tests and shaking table tests has been conducted for a full scale power generator supported by four sets of spring vibration isolators (YS-2-2400A). The hysteretic behavior and seismic responses of the isolation system is investigated. In addition the damage mechanism of the isolator is also identified. Besides, additional restrainer to enhance the seismic resistance (YS-7500EL) is added to the vibration isolation system. Same tests are performed and the test results are compared with those without the additional restrainers.
|
author2 |
Jenn-Shin Hwang |
author_facet |
Jenn-Shin Hwang JING-WEN JENG 鄭景文 |
author |
JING-WEN JENG 鄭景文 |
spellingShingle |
JING-WEN JENG 鄭景文 Experimental Study of A Full-Scale Vibration Isolated Mechanical/Electrical Equipment |
author_sort |
JING-WEN JENG |
title |
Experimental Study of A Full-Scale Vibration Isolated Mechanical/Electrical Equipment |
title_short |
Experimental Study of A Full-Scale Vibration Isolated Mechanical/Electrical Equipment |
title_full |
Experimental Study of A Full-Scale Vibration Isolated Mechanical/Electrical Equipment |
title_fullStr |
Experimental Study of A Full-Scale Vibration Isolated Mechanical/Electrical Equipment |
title_full_unstemmed |
Experimental Study of A Full-Scale Vibration Isolated Mechanical/Electrical Equipment |
title_sort |
experimental study of a full-scale vibration isolated mechanical/electrical equipment |
publishDate |
2011 |
url |
http://ndltd.ncl.edu.tw/handle/gzr49b |
work_keys_str_mv |
AT jingwenjeng experimentalstudyofafullscalevibrationisolatedmechanicalelectricalequipment AT zhèngjǐngwén experimentalstudyofafullscalevibrationisolatedmechanicalelectricalequipment AT jingwenjeng hángézhènzhuāngzhìzhīzúchǐjīdiànshèbèishìyànyánjiū AT zhèngjǐngwén hángézhènzhuāngzhìzhīzúchǐjīdiànshèbèishìyànyánjiū |
_version_ |
1719102343640776704 |