Real-time Insulation Status Assessment of High Voltage Underground Cable Joints
碩士 === 國立臺灣科技大學 === 電機工程系 === 99 === Underground cables are the main apparatus of electricity transmission in recent urban. The common defects usually existed in the artificial connection part. Under a long-term operation, these defects might become unexpected accident. In recent, a long-term monito...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2011
|
Online Access: | http://ndltd.ncl.edu.tw/handle/yezf4c |
id |
ndltd-TW-099NTUS5442088 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099NTUS54420882019-05-15T20:42:06Z http://ndltd.ncl.edu.tw/handle/yezf4c Real-time Insulation Status Assessment of High Voltage Underground Cable Joints 高電壓地下電纜接頭絕緣狀態即時性評估之研究 Jun-Yan He 何俊彥 碩士 國立臺灣科技大學 電機工程系 99 Underground cables are the main apparatus of electricity transmission in recent urban. The common defects usually existed in the artificial connection part. Under a long-term operation, these defects might become unexpected accident. In recent, a long-term monitoring of underground cable joint is a method to avoid accident. Increasing with time during long-term monitoring, the data size might reach the limit of measuring device. This research proposed a real-time insulation status assessment method for underground cable joint. This method includes the acquisition of test voltage and PD signal, simplification, transformation, and extraction. In order to solve the problem of limitation of data, the extracted data will be shifted by a fixed width to calculate a feature and assessment value of insulation status. The duration, which feature is over the assessment value, is represented as the transition period of insulation status. When the assessment value is 3 times the standard deviation, two transition periods can be effectively detected. These two transition periods were used to determine the insulation status, including early, middle and final term. Finally, no matter using wavelet filtering or not, this method can assess insulation status effectively. Finally, comparing the use of wavelet filtering, the diagnosis of insulation status without wavelet filtering was feasible and improved the operation speed and program complexity. Ruay-Nan Wu 吳瑞南 2011 學位論文 ; thesis 71 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣科技大學 === 電機工程系 === 99 === Underground cables are the main apparatus of electricity transmission in recent urban. The common defects usually existed in the artificial connection part. Under a long-term operation, these defects might become unexpected accident. In recent, a long-term monitoring of underground cable joint is a method to avoid accident. Increasing with time during long-term monitoring, the data size might reach the limit of measuring device.
This research proposed a real-time insulation status assessment method for underground cable joint. This method includes the acquisition of test voltage and PD signal, simplification, transformation, and extraction. In order to solve the problem of limitation of data, the extracted data will be shifted by a fixed width to calculate a feature and assessment value of insulation status. The duration, which feature is over the assessment value, is represented as the transition period of insulation status. When the assessment value is 3 times the standard deviation, two transition periods can be effectively detected. These two transition periods were used to determine the insulation status, including early, middle and final term. Finally, no matter using wavelet filtering or not, this method can assess insulation status effectively. Finally, comparing the use of wavelet filtering, the diagnosis of insulation status without wavelet filtering was feasible and improved the operation speed and program complexity.
|
author2 |
Ruay-Nan Wu |
author_facet |
Ruay-Nan Wu Jun-Yan He 何俊彥 |
author |
Jun-Yan He 何俊彥 |
spellingShingle |
Jun-Yan He 何俊彥 Real-time Insulation Status Assessment of High Voltage Underground Cable Joints |
author_sort |
Jun-Yan He |
title |
Real-time Insulation Status Assessment of High Voltage Underground Cable Joints |
title_short |
Real-time Insulation Status Assessment of High Voltage Underground Cable Joints |
title_full |
Real-time Insulation Status Assessment of High Voltage Underground Cable Joints |
title_fullStr |
Real-time Insulation Status Assessment of High Voltage Underground Cable Joints |
title_full_unstemmed |
Real-time Insulation Status Assessment of High Voltage Underground Cable Joints |
title_sort |
real-time insulation status assessment of high voltage underground cable joints |
publishDate |
2011 |
url |
http://ndltd.ncl.edu.tw/handle/yezf4c |
work_keys_str_mv |
AT junyanhe realtimeinsulationstatusassessmentofhighvoltageundergroundcablejoints AT héjùnyàn realtimeinsulationstatusassessmentofhighvoltageundergroundcablejoints AT junyanhe gāodiànyādexiàdiànlǎnjiētóujuéyuánzhuàngtàijíshíxìngpínggūzhīyánjiū AT héjùnyàn gāodiànyādexiàdiànlǎnjiētóujuéyuánzhuàngtàijíshíxìngpínggūzhīyánjiū |
_version_ |
1719102213266079744 |