The Design of Analog-to-Digital Converter for Bio-Medical Application
碩士 === 國立臺灣大學 === 電子工程學研究所 === 99 === Since the life of human beings has been extended and social structure changed, biomedical application area has been fast developed and becomes a vital issue. Electrical engineers have turned their attention from consumer products to biomedical area. In order to...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
2011
|
Online Access: | http://ndltd.ncl.edu.tw/handle/54963105460847292099 |
id |
ndltd-TW-099NTU05428094 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099NTU054280942015-10-16T04:03:08Z http://ndltd.ncl.edu.tw/handle/54963105460847292099 The Design of Analog-to-Digital Converter for Bio-Medical Application 應用於生醫系統之類比數位轉換器設計 Sheng-Ruei Hsu 許升睿 碩士 國立臺灣大學 電子工程學研究所 99 Since the life of human beings has been extended and social structure changed, biomedical application area has been fast developed and becomes a vital issue. Electrical engineers have turned their attention from consumer products to biomedical area. In order to follow this trend, we design ADCs that are suitable for biomedical application. In this thesis, we have designed two ADCs. First, a sigma delta modulator is presented. Its structure is suitable for high-resolution application from the result of past references. We use TSMC CMOS 0.35um process. The structure is switch-capacitor second-order architecture. Target bandwidth is 22.05KHz and have sampling rate 2,56MHz, that means we have OSR of 56. Under 3-V power supply condition, the maximum SNDR is 49dB, which is about 7.8 ENOB, and achieving 54dB dynamic range. Total area is 0.98x0.68mm2 and power consumption is 3mW. The second ADC is successive approximation ADC, the property of this circuit is low power consumption. This circuit is fabricated in TSMC 0.18um process and operates under 1-V power supply in order to save power. The target resolution is 10-bit. We use integer capacitor bridge to save chip area and maintain good capacitor mismatch. Our sampling frequency is 400KHz. Under Nyquist rate operation, maximum SNDR is 49.3dB, which is about 7.9 ENOB. Static testing performances INL is 2/-1.9 LSB and DNL is 1/-0.9 LSB. Power consumption is 9.5uW, FOM is 99fJ/conv., which is competitive among references. 呂學士 2011 學位論文 ; thesis 106 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣大學 === 電子工程學研究所 === 99 === Since the life of human beings has been extended and social structure changed, biomedical application area has been fast developed and becomes a vital issue. Electrical engineers have turned their attention from consumer products to biomedical area. In order to follow this trend, we design ADCs that are suitable for biomedical application.
In this thesis, we have designed two ADCs. First, a sigma delta modulator is presented. Its structure is suitable for high-resolution application from the result of past references. We use TSMC CMOS 0.35um process. The structure is switch-capacitor second-order architecture. Target bandwidth is 22.05KHz and have sampling rate 2,56MHz, that means we have OSR of 56. Under 3-V power supply condition, the maximum SNDR is 49dB, which is about 7.8 ENOB, and achieving 54dB dynamic range. Total area is 0.98x0.68mm2 and power consumption is 3mW.
The second ADC is successive approximation ADC, the property of this circuit is low power consumption. This circuit is fabricated in TSMC 0.18um process and operates under 1-V power supply in order to save power. The target resolution is 10-bit. We use integer capacitor bridge to save chip area and maintain good capacitor mismatch. Our sampling frequency is 400KHz. Under Nyquist rate operation, maximum SNDR is 49.3dB, which is about 7.9 ENOB. Static testing performances INL is 2/-1.9 LSB and DNL is 1/-0.9 LSB. Power consumption is 9.5uW, FOM is 99fJ/conv., which is competitive among references.
|
author2 |
呂學士 |
author_facet |
呂學士 Sheng-Ruei Hsu 許升睿 |
author |
Sheng-Ruei Hsu 許升睿 |
spellingShingle |
Sheng-Ruei Hsu 許升睿 The Design of Analog-to-Digital Converter for Bio-Medical Application |
author_sort |
Sheng-Ruei Hsu |
title |
The Design of Analog-to-Digital Converter for Bio-Medical Application |
title_short |
The Design of Analog-to-Digital Converter for Bio-Medical Application |
title_full |
The Design of Analog-to-Digital Converter for Bio-Medical Application |
title_fullStr |
The Design of Analog-to-Digital Converter for Bio-Medical Application |
title_full_unstemmed |
The Design of Analog-to-Digital Converter for Bio-Medical Application |
title_sort |
design of analog-to-digital converter for bio-medical application |
publishDate |
2011 |
url |
http://ndltd.ncl.edu.tw/handle/54963105460847292099 |
work_keys_str_mv |
AT shengrueihsu thedesignofanalogtodigitalconverterforbiomedicalapplication AT xǔshēngruì thedesignofanalogtodigitalconverterforbiomedicalapplication AT shengrueihsu yīngyòngyúshēngyīxìtǒngzhīlèibǐshùwèizhuǎnhuànqìshèjì AT xǔshēngruì yīngyòngyúshēngyīxìtǒngzhīlèibǐshùwèizhuǎnhuànqìshèjì AT shengrueihsu designofanalogtodigitalconverterforbiomedicalapplication AT xǔshēngruì designofanalogtodigitalconverterforbiomedicalapplication |
_version_ |
1718092057378029568 |