碩士 === 國立屏東教育大學 === 體育學系 === 99 === Purpose: The purpose of this study was to construct a portable and expandable data acquisition device for reaction time measurement by using virtual instrumentation. Method: The designed circuit was first simulated by Multisim software and certified with Education...

Full description

Bibliographic Details
Main Authors: Cheung-Sang Chue, 徐章生
Other Authors: Jui-Hung Tu
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/39162755063276138443
id ndltd-TW-099NPTT5567023
record_format oai_dc
spelling ndltd-TW-099NPTT55670232015-10-13T19:07:22Z http://ndltd.ncl.edu.tw/handle/39162755063276138443 The development of reaction time measurement device by using virtual instrumentation 人體反應時間量測裝置之建構與應用-以虛擬儀表的技術為基礎 Cheung-Sang Chue 徐章生 碩士 國立屏東教育大學 體育學系 99 Purpose: The purpose of this study was to construct a portable and expandable data acquisition device for reaction time measurement by using virtual instrumentation. Method: The designed circuit was first simulated by Multisim software and certified with Educational Laboratory Virtual Instrumentation Suite (ELVIS II+). A prototype printed circuit board (PCB) was integrated with a data acquisition board (USB- 6009) and finally LabVIEW was used to build human machine interface (HMI). The device was tested by a 100MHz scope and function generator (ELVIS II+) before the experiment. Two experiments were also executed for testing the device. The first experiment was to measure TRT by pressing a button with a finger after sound and light stimuli. The pre-motor reaction time (PRT) and motor reaction time (MRT) for grip movement after sound and light stimuli were measured with EMG in the other experiment. 36 subjects were chosen randomly from department of physical education of NPUE. Results: The device was constructed and tested under different situation successfully. Conclusion: The result showed the device is able to measure RT-related parameters accurately and rapidly. It can also combine with other sensors for measuring other parameters of kinesiology and applied to further research. Jui-Hung Tu 涂瑞洪 2011 學位論文 ; thesis 49 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立屏東教育大學 === 體育學系 === 99 === Purpose: The purpose of this study was to construct a portable and expandable data acquisition device for reaction time measurement by using virtual instrumentation. Method: The designed circuit was first simulated by Multisim software and certified with Educational Laboratory Virtual Instrumentation Suite (ELVIS II+). A prototype printed circuit board (PCB) was integrated with a data acquisition board (USB- 6009) and finally LabVIEW was used to build human machine interface (HMI). The device was tested by a 100MHz scope and function generator (ELVIS II+) before the experiment. Two experiments were also executed for testing the device. The first experiment was to measure TRT by pressing a button with a finger after sound and light stimuli. The pre-motor reaction time (PRT) and motor reaction time (MRT) for grip movement after sound and light stimuli were measured with EMG in the other experiment. 36 subjects were chosen randomly from department of physical education of NPUE. Results: The device was constructed and tested under different situation successfully. Conclusion: The result showed the device is able to measure RT-related parameters accurately and rapidly. It can also combine with other sensors for measuring other parameters of kinesiology and applied to further research.
author2 Jui-Hung Tu
author_facet Jui-Hung Tu
Cheung-Sang Chue
徐章生
author Cheung-Sang Chue
徐章生
spellingShingle Cheung-Sang Chue
徐章生
The development of reaction time measurement device by using virtual instrumentation
author_sort Cheung-Sang Chue
title The development of reaction time measurement device by using virtual instrumentation
title_short The development of reaction time measurement device by using virtual instrumentation
title_full The development of reaction time measurement device by using virtual instrumentation
title_fullStr The development of reaction time measurement device by using virtual instrumentation
title_full_unstemmed The development of reaction time measurement device by using virtual instrumentation
title_sort development of reaction time measurement device by using virtual instrumentation
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/39162755063276138443
work_keys_str_mv AT cheungsangchue thedevelopmentofreactiontimemeasurementdevicebyusingvirtualinstrumentation
AT xúzhāngshēng thedevelopmentofreactiontimemeasurementdevicebyusingvirtualinstrumentation
AT cheungsangchue réntǐfǎnyīngshíjiānliàngcèzhuāngzhìzhījiàngòuyǔyīngyòngyǐxūnǐyíbiǎodejìshùwèijīchǔ
AT xúzhāngshēng réntǐfǎnyīngshíjiānliàngcèzhuāngzhìzhījiàngòuyǔyīngyòngyǐxūnǐyíbiǎodejìshùwèijīchǔ
AT cheungsangchue developmentofreactiontimemeasurementdevicebyusingvirtualinstrumentation
AT xúzhāngshēng developmentofreactiontimemeasurementdevicebyusingvirtualinstrumentation
_version_ 1718041817170051072