A wearable fall detector using inertial sensors and electromyography

碩士 === 國立交通大學 === 機械工程學系 === 99 ===     Falls are leading causes of unintentional injuries and deaths in the elderly. To detect falls early and accurately is important for reducing fall-related socioeconomic cost. Inertial sensors have been used to distinguish fall from activities of daily living (A...

Full description

Bibliographic Details
Main Authors: Liao, Sian-Ting, 廖顯庭
Other Authors: Yang, Bing-Shiang
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/04577504718750660872
id ndltd-TW-099NCTU5489108
record_format oai_dc
spelling ndltd-TW-099NCTU54891082015-10-13T20:37:27Z http://ndltd.ncl.edu.tw/handle/04577504718750660872 A wearable fall detector using inertial sensors and electromyography 整合慣性感測器與肌電訊號量測之穿戴式跌倒感測器 Liao, Sian-Ting 廖顯庭 碩士 國立交通大學 機械工程學系 99     Falls are leading causes of unintentional injuries and deaths in the elderly. To detect falls early and accurately is important for reducing fall-related socioeconomic cost. Inertial sensors have been used to distinguish fall from activities of daily living (ADLs). Our previous study found that using electromyography (EMG) signals on fall detection has advantage on recognition speed. Therefore, the aim of this study was to further develop a wearable fall detector by using inertial and electromyography combined sensors to detect fall events before impact.     We have established a prototype of a fall detector, combing a tri-axis accelerometer and a tri-axis gyroscope, attached to the frontal surface of waist, and two-channel EMG sensors, recording the activities of bilateral rectus femoris muscles. Six subjects (23.3±1.0 yrs; 168.7±6.4 cm; 60.7±3.98kg) volunteered to the experiment for evaluating the performance of the fall detector. Each subject performed several ADLs in a mimic living environment and a few unexpected simulated trips, induced by a custom-made device attached to the ankle, were interspersed among the ADLs. Self-developed detecting algorithms were used to distinguish falls (trips) from ADLs, and a optimal detecting algorithm was then determined based on the detecting performance using a set of statistical analyses.     Using inertial sensors alone could detect fall with 89.6% sensitivity and 98.3% specificity. By using EMG alone, sensitivity was 72.9% and specificity 92.0%. The fall detector using the combined sensor could identify falls before the impact between the human body and floor, with sensitivity of 81.2% and specificity of 98.6% with 264±178 ms mean lead time. To detect fall using inertial sensors are more accurate than using EMG signals alone. However the addition of EMG sensors to inertia sensors allowed our system to have about 50 ms more lead time. Besides, the lower limit of the 95% confidence interval of the system sensitivity was 73.0%, which may still be suitable for some real-life application. In conclusion, we have demonstrated the possibility of using EMG sensors combined with accelerometers to provide accurate and fast trip-fall detection. Yang, Bing-Shiang 楊秉祥 2011 學位論文 ; thesis 85 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立交通大學 === 機械工程學系 === 99 ===     Falls are leading causes of unintentional injuries and deaths in the elderly. To detect falls early and accurately is important for reducing fall-related socioeconomic cost. Inertial sensors have been used to distinguish fall from activities of daily living (ADLs). Our previous study found that using electromyography (EMG) signals on fall detection has advantage on recognition speed. Therefore, the aim of this study was to further develop a wearable fall detector by using inertial and electromyography combined sensors to detect fall events before impact.     We have established a prototype of a fall detector, combing a tri-axis accelerometer and a tri-axis gyroscope, attached to the frontal surface of waist, and two-channel EMG sensors, recording the activities of bilateral rectus femoris muscles. Six subjects (23.3±1.0 yrs; 168.7±6.4 cm; 60.7±3.98kg) volunteered to the experiment for evaluating the performance of the fall detector. Each subject performed several ADLs in a mimic living environment and a few unexpected simulated trips, induced by a custom-made device attached to the ankle, were interspersed among the ADLs. Self-developed detecting algorithms were used to distinguish falls (trips) from ADLs, and a optimal detecting algorithm was then determined based on the detecting performance using a set of statistical analyses.     Using inertial sensors alone could detect fall with 89.6% sensitivity and 98.3% specificity. By using EMG alone, sensitivity was 72.9% and specificity 92.0%. The fall detector using the combined sensor could identify falls before the impact between the human body and floor, with sensitivity of 81.2% and specificity of 98.6% with 264±178 ms mean lead time. To detect fall using inertial sensors are more accurate than using EMG signals alone. However the addition of EMG sensors to inertia sensors allowed our system to have about 50 ms more lead time. Besides, the lower limit of the 95% confidence interval of the system sensitivity was 73.0%, which may still be suitable for some real-life application. In conclusion, we have demonstrated the possibility of using EMG sensors combined with accelerometers to provide accurate and fast trip-fall detection.
author2 Yang, Bing-Shiang
author_facet Yang, Bing-Shiang
Liao, Sian-Ting
廖顯庭
author Liao, Sian-Ting
廖顯庭
spellingShingle Liao, Sian-Ting
廖顯庭
A wearable fall detector using inertial sensors and electromyography
author_sort Liao, Sian-Ting
title A wearable fall detector using inertial sensors and electromyography
title_short A wearable fall detector using inertial sensors and electromyography
title_full A wearable fall detector using inertial sensors and electromyography
title_fullStr A wearable fall detector using inertial sensors and electromyography
title_full_unstemmed A wearable fall detector using inertial sensors and electromyography
title_sort wearable fall detector using inertial sensors and electromyography
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/04577504718750660872
work_keys_str_mv AT liaosianting awearablefalldetectorusinginertialsensorsandelectromyography
AT liàoxiǎntíng awearablefalldetectorusinginertialsensorsandelectromyography
AT liaosianting zhěnghéguànxìnggǎncèqìyǔjīdiànxùnhàoliàngcèzhīchuāndàishìdiēdàogǎncèqì
AT liàoxiǎntíng zhěnghéguànxìnggǎncèqìyǔjīdiànxùnhàoliàngcèzhīchuāndàishìdiēdàogǎncèqì
AT liaosianting wearablefalldetectorusinginertialsensorsandelectromyography
AT liàoxiǎntíng wearablefalldetectorusinginertialsensorsandelectromyography
_version_ 1718049701955108864