Measurement of evacuation velocity and numerical analysis of the flow field for a siphon-type water closet
碩士 === 龍華科技大學 === 工程技術研究所 === 99 === Extreme climate and environment pollution is causing water deficient around the world. This arouses the whole world to seriously consider water-saving issue. It is a government regulation that no more than 6 liters of water is allowed for one flush of water clos...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2011
|
Online Access: | http://ndltd.ncl.edu.tw/handle/69967829598609462253 |
id |
ndltd-TW-099LHU05489013 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099LHU054890132015-10-13T20:46:53Z http://ndltd.ncl.edu.tw/handle/69967829598609462253 Measurement of evacuation velocity and numerical analysis of the flow field for a siphon-type water closet 虹吸式馬桶之沖刷速度量測與流場分析 Chao-yu Jhang 張朝毓 碩士 龍華科技大學 工程技術研究所 99 Extreme climate and environment pollution is causing water deficient around the world. This arouses the whole world to seriously consider water-saving issue. It is a government regulation that no more than 6 liters of water is allowed for one flush of water closets. This research studies the flush performance of a siphon-type water closet under such limitation. Previous study suggests that a well-performed water closet has higher axial water velocity in the water channel. This is used as the standard for performance comparison. Particle tracing technique with a high speed camera is used to measure the axial-flow velocity of water in the tunnel. However, commercial software for numerical analysis is used for subsequent study. Detail information including axial velocity, swirl velocity of water and the proportion of air residing in the tunnel to block the water flow, can all be more clearly understood by numerical simulation. Our results show that: (1) the location of water falls into the bowel of water closets affects the evacuation performance. (2) Air resides in the tunnel reduces the flow velocity, in other words, reduces performance. (3) The sooner the swirling velocity of water flow shows up, the higher the evacuation performance. Wei-seng Cheng 鄭偉盛 2011 學位論文 ; thesis 76 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 龍華科技大學 === 工程技術研究所 === 99 === Extreme climate and environment pollution is causing water deficient around the world. This arouses the whole world to seriously consider water-saving issue. It is a government regulation that no more than 6 liters of water is allowed for one flush of water closets. This research studies the flush performance of a siphon-type water closet under such limitation. Previous study suggests that a well-performed water closet has higher axial water velocity in the water channel. This is used as the standard for performance comparison.
Particle tracing technique with a high speed camera is used to measure the axial-flow velocity of water in the tunnel. However, commercial software for numerical analysis is used for subsequent study. Detail information including axial velocity, swirl velocity of water and the proportion of air residing in the tunnel to block the water flow, can all be more clearly understood by numerical simulation.
Our results show that: (1) the location of water falls into the bowel of water closets affects the evacuation performance. (2) Air resides in the tunnel reduces the flow velocity, in other words, reduces performance. (3) The sooner the swirling velocity of water flow shows up, the higher the evacuation performance.
|
author2 |
Wei-seng Cheng |
author_facet |
Wei-seng Cheng Chao-yu Jhang 張朝毓 |
author |
Chao-yu Jhang 張朝毓 |
spellingShingle |
Chao-yu Jhang 張朝毓 Measurement of evacuation velocity and numerical analysis of the flow field for a siphon-type water closet |
author_sort |
Chao-yu Jhang |
title |
Measurement of evacuation velocity and numerical analysis of the flow field for a siphon-type water closet |
title_short |
Measurement of evacuation velocity and numerical analysis of the flow field for a siphon-type water closet |
title_full |
Measurement of evacuation velocity and numerical analysis of the flow field for a siphon-type water closet |
title_fullStr |
Measurement of evacuation velocity and numerical analysis of the flow field for a siphon-type water closet |
title_full_unstemmed |
Measurement of evacuation velocity and numerical analysis of the flow field for a siphon-type water closet |
title_sort |
measurement of evacuation velocity and numerical analysis of the flow field for a siphon-type water closet |
publishDate |
2011 |
url |
http://ndltd.ncl.edu.tw/handle/69967829598609462253 |
work_keys_str_mv |
AT chaoyujhang measurementofevacuationvelocityandnumericalanalysisoftheflowfieldforasiphontypewatercloset AT zhāngcháoyù measurementofevacuationvelocityandnumericalanalysisoftheflowfieldforasiphontypewatercloset AT chaoyujhang hóngxīshìmǎtǒngzhīchōngshuāsùdùliàngcèyǔliúchǎngfēnxī AT zhāngcháoyù hóngxīshìmǎtǒngzhīchōngshuāsùdùliàngcèyǔliúchǎngfēnxī |
_version_ |
1718050289579196416 |