Risk Investigation of the Fall-arrest plate using FMEA method

碩士 === 弘光科技大學 === 職業安全與防災研究所 === 99 === Fall-arrest plate is a high risk of construction technology, The failure mode and effect analysis method (FMEA) is selected to measure the risk. The occurrence, severity and detectable factors were considered in the questionnaire. From the answers of the 18 sp...

Full description

Bibliographic Details
Main Author: 陳沛蓬
Other Authors: 蘇光偉
Format: Others
Language:zh-TW
Online Access:http://ndltd.ncl.edu.tw/handle/00051521505808993088
id ndltd-TW-099HKU05590005
record_format oai_dc
spelling ndltd-TW-099HKU055900052015-10-13T20:09:18Z http://ndltd.ncl.edu.tw/handle/00051521505808993088 Risk Investigation of the Fall-arrest plate using FMEA method 以失效模式與效能分析對斜籬組拆作業及防墜功能進行風險探討 陳沛蓬 碩士 弘光科技大學 職業安全與防災研究所 99 Fall-arrest plate is a high risk of construction technology, The failure mode and effect analysis method (FMEA) is selected to measure the risk. The occurrence, severity and detectable factors were considered in the questionnaire. From the answers of the 18 specialty engineers, the assembling and the dismounting stages have higher risk for workers. Matches the dynamic test, effect of the confirmation interception. The analysis calculated the risk priority index sequencing results, Drinking alcoholic beverages is the most dangerous, followed by the former is not really tied Material Handling, By the results of planning for improvement, to reduce disasters. The dynamic test was also implemented for the fall-arrest effect of the plate. It is found that the weight of the flying objects was not the only controlling factor to damage the fall-arrest plate. Flying objects with thin and sharp ends would wear out the plate more easer than the concrete bricks. Collection of works by the operating personnel and facilities for filming the current situation, According to the review group to split the job of risk factors, And taking into account any relevant foreign standards, Prepare standard operating procedures, Provide the industry as a staff training purposes. This study suggests that agencies will include specification standard operating procedures to facilitate the industry to follow and as an educational advocacy materials. Need to set the height and spacing, tilt angle (> 20 °) and horizontal extension of the length (≧ 2m). And testing standards are brought together to facilitate the examination. Key Words: FMEA, fall-arrest plate, scaffold, risk assessment 蘇光偉 學位論文 ; thesis 106 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 弘光科技大學 === 職業安全與防災研究所 === 99 === Fall-arrest plate is a high risk of construction technology, The failure mode and effect analysis method (FMEA) is selected to measure the risk. The occurrence, severity and detectable factors were considered in the questionnaire. From the answers of the 18 specialty engineers, the assembling and the dismounting stages have higher risk for workers. Matches the dynamic test, effect of the confirmation interception. The analysis calculated the risk priority index sequencing results, Drinking alcoholic beverages is the most dangerous, followed by the former is not really tied Material Handling, By the results of planning for improvement, to reduce disasters. The dynamic test was also implemented for the fall-arrest effect of the plate. It is found that the weight of the flying objects was not the only controlling factor to damage the fall-arrest plate. Flying objects with thin and sharp ends would wear out the plate more easer than the concrete bricks. Collection of works by the operating personnel and facilities for filming the current situation, According to the review group to split the job of risk factors, And taking into account any relevant foreign standards, Prepare standard operating procedures, Provide the industry as a staff training purposes. This study suggests that agencies will include specification standard operating procedures to facilitate the industry to follow and as an educational advocacy materials. Need to set the height and spacing, tilt angle (> 20 °) and horizontal extension of the length (≧ 2m). And testing standards are brought together to facilitate the examination. Key Words: FMEA, fall-arrest plate, scaffold, risk assessment
author2 蘇光偉
author_facet 蘇光偉
陳沛蓬
author 陳沛蓬
spellingShingle 陳沛蓬
Risk Investigation of the Fall-arrest plate using FMEA method
author_sort 陳沛蓬
title Risk Investigation of the Fall-arrest plate using FMEA method
title_short Risk Investigation of the Fall-arrest plate using FMEA method
title_full Risk Investigation of the Fall-arrest plate using FMEA method
title_fullStr Risk Investigation of the Fall-arrest plate using FMEA method
title_full_unstemmed Risk Investigation of the Fall-arrest plate using FMEA method
title_sort risk investigation of the fall-arrest plate using fmea method
url http://ndltd.ncl.edu.tw/handle/00051521505808993088
work_keys_str_mv AT chénpèipéng riskinvestigationofthefallarrestplateusingfmeamethod
AT chénpèipéng yǐshīxiàomóshìyǔxiàonéngfēnxīduìxiélízǔchāizuòyèjífángzhuìgōngnéngjìnxíngfēngxiǎntàntǎo
_version_ 1718044383870189568