Risk Investigation of the Fall-arrest plate using FMEA method
碩士 === 弘光科技大學 === 職業安全與防災研究所 === 99 === Fall-arrest plate is a high risk of construction technology, The failure mode and effect analysis method (FMEA) is selected to measure the risk. The occurrence, severity and detectable factors were considered in the questionnaire. From the answers of the 18 sp...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Online Access: | http://ndltd.ncl.edu.tw/handle/00051521505808993088 |
id |
ndltd-TW-099HKU05590005 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099HKU055900052015-10-13T20:09:18Z http://ndltd.ncl.edu.tw/handle/00051521505808993088 Risk Investigation of the Fall-arrest plate using FMEA method 以失效模式與效能分析對斜籬組拆作業及防墜功能進行風險探討 陳沛蓬 碩士 弘光科技大學 職業安全與防災研究所 99 Fall-arrest plate is a high risk of construction technology, The failure mode and effect analysis method (FMEA) is selected to measure the risk. The occurrence, severity and detectable factors were considered in the questionnaire. From the answers of the 18 specialty engineers, the assembling and the dismounting stages have higher risk for workers. Matches the dynamic test, effect of the confirmation interception. The analysis calculated the risk priority index sequencing results, Drinking alcoholic beverages is the most dangerous, followed by the former is not really tied Material Handling, By the results of planning for improvement, to reduce disasters. The dynamic test was also implemented for the fall-arrest effect of the plate. It is found that the weight of the flying objects was not the only controlling factor to damage the fall-arrest plate. Flying objects with thin and sharp ends would wear out the plate more easer than the concrete bricks. Collection of works by the operating personnel and facilities for filming the current situation, According to the review group to split the job of risk factors, And taking into account any relevant foreign standards, Prepare standard operating procedures, Provide the industry as a staff training purposes. This study suggests that agencies will include specification standard operating procedures to facilitate the industry to follow and as an educational advocacy materials. Need to set the height and spacing, tilt angle (> 20 °) and horizontal extension of the length (≧ 2m). And testing standards are brought together to facilitate the examination. Key Words: FMEA, fall-arrest plate, scaffold, risk assessment 蘇光偉 學位論文 ; thesis 106 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 弘光科技大學 === 職業安全與防災研究所 === 99 === Fall-arrest plate is a high risk of construction technology, The failure mode and effect analysis method (FMEA) is selected to measure the risk. The occurrence, severity and detectable factors were considered in the questionnaire. From the answers of the 18 specialty engineers, the assembling and the dismounting stages have higher risk for workers. Matches the dynamic test, effect of the confirmation interception.
The analysis calculated the risk priority index sequencing results, Drinking alcoholic beverages is the most dangerous, followed by the former is not really tied Material Handling, By the results of planning for improvement, to reduce disasters. The dynamic test was also implemented for the fall-arrest effect of the plate. It is found that the weight of the flying objects was not the only controlling factor to damage the fall-arrest plate. Flying objects with thin and sharp ends would wear out the plate more easer than the concrete bricks. Collection of works by the operating personnel and facilities for filming the current situation, According to the review group to split the job of risk factors, And taking into account any relevant foreign standards, Prepare standard operating procedures, Provide the industry as a staff training purposes.
This study suggests that agencies will include specification standard operating procedures to facilitate the industry to follow and as an educational advocacy materials. Need to set the height and spacing, tilt angle (> 20 °) and horizontal extension of the length (≧ 2m). And testing standards are brought together to facilitate the examination.
Key Words: FMEA, fall-arrest plate, scaffold, risk assessment
|
author2 |
蘇光偉 |
author_facet |
蘇光偉 陳沛蓬 |
author |
陳沛蓬 |
spellingShingle |
陳沛蓬 Risk Investigation of the Fall-arrest plate using FMEA method |
author_sort |
陳沛蓬 |
title |
Risk Investigation of the Fall-arrest plate using FMEA method |
title_short |
Risk Investigation of the Fall-arrest plate using FMEA method |
title_full |
Risk Investigation of the Fall-arrest plate using FMEA method |
title_fullStr |
Risk Investigation of the Fall-arrest plate using FMEA method |
title_full_unstemmed |
Risk Investigation of the Fall-arrest plate using FMEA method |
title_sort |
risk investigation of the fall-arrest plate using fmea method |
url |
http://ndltd.ncl.edu.tw/handle/00051521505808993088 |
work_keys_str_mv |
AT chénpèipéng riskinvestigationofthefallarrestplateusingfmeamethod AT chénpèipéng yǐshīxiàomóshìyǔxiàonéngfēnxīduìxiélízǔchāizuòyèjífángzhuìgōngnéngjìnxíngfēngxiǎntàntǎo |
_version_ |
1718044383870189568 |