The Assistance of Tomosynthesis Image Reformation using MATLAB Image Processing Tool-box for Department of Radiology.
碩士 === 中原大學 === 生物醫學工程研究所 === 99 === This study was using the tomosynthesis technique and the ACR CT accreditation phantom to verify the relationship of the swing angle of x-ray tube and sectional thickness. In addition, the grayscale linearity, the reconstruction time for different algorithm, the c...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2011
|
Online Access: | http://ndltd.ncl.edu.tw/handle/88936739532588451219 |
id |
ndltd-TW-099CYCU5114010 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099CYCU51140102015-10-13T20:23:26Z http://ndltd.ncl.edu.tw/handle/88936739532588451219 The Assistance of Tomosynthesis Image Reformation using MATLAB Image Processing Tool-box for Department of Radiology. 利用MATLAB影像處理工具盒重組斷層層析影像對影像診療科的輔助 Chih-Sheng Yeh 葉志盛 碩士 中原大學 生物醫學工程研究所 99 This study was using the tomosynthesis technique and the ACR CT accreditation phantom to verify the relationship of the swing angle of x-ray tube and sectional thickness. In addition, the grayscale linearity, the reconstruction time for different algorithm, the calculated volume accuracy, and the effectiveness of images reconstructed along various directions were evaluated. The tomosynthesis technique in flat panel digital X-Ray system uses similar “twinning principle” theory to tomography to produce serial sectional images of human body. The grayscale linearity of reconstructed images was similar to the results from CT images. The pixel size of reconstructed tomosynthesis images was 0.298 mm*0.298 mm. The reconstruction time for 41 images using filtered back projection was 27 seconds faster than shift and add algorithm. The sectional thickness of each tomosynthesis image was able to reach as thin as 2 mm using 40 degrees swing angle of x-ray tube. In the analysis of the agreement of using fluoroscopy or tomosynthesis to identify the relative location between instrument and specific tissue, the result of Wilcoxon signed-rank test, the p-value, was 0.0016. This implies that using tomosynthesis images in localization of instrument in diagnosis and/or treatment was superior to using conventional superimposed images. The relative distance can be calculated from these images. Therefore, during the fluoroscopy guided diagnosis or treatment, this technique provides additional spatial information to the radiologists and improve the accuracy of localization. With the helpful of these images, the radiologist can have more accurate spatial information during fluoroscopy guided procedures, such as percutaneous gastrostomy, and may shorten the process of operation. Wei-Chih Hu 胡威志 2011 學位論文 ; thesis 60 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中原大學 === 生物醫學工程研究所 === 99 === This study was using the tomosynthesis technique and the ACR CT accreditation phantom to verify the relationship of the swing angle of x-ray tube and sectional thickness. In addition, the grayscale linearity, the reconstruction time for different algorithm, the calculated volume accuracy, and the effectiveness of images reconstructed along various directions were evaluated. The tomosynthesis technique in flat panel digital X-Ray system uses similar “twinning principle” theory to tomography to produce serial sectional images of human body. The grayscale linearity of reconstructed images was similar to the results from CT images. The pixel size of reconstructed tomosynthesis images was 0.298 mm*0.298 mm. The reconstruction time for 41 images using filtered back projection was 27 seconds faster than shift and add algorithm. The sectional thickness of each tomosynthesis image was able to reach as thin as 2 mm using 40 degrees swing angle of x-ray tube. In the analysis of the agreement of using fluoroscopy or tomosynthesis to identify the relative location between instrument and specific tissue, the result of Wilcoxon signed-rank test, the p-value, was 0.0016. This implies that using tomosynthesis images in localization of instrument in diagnosis and/or treatment was superior to using conventional superimposed images. The relative distance can be calculated from these images. Therefore, during the fluoroscopy guided diagnosis or treatment, this technique provides additional spatial information to the radiologists and improve the accuracy of localization. With the helpful of these images, the radiologist can have more accurate spatial information during fluoroscopy guided procedures, such as percutaneous gastrostomy, and may shorten the process of operation.
|
author2 |
Wei-Chih Hu |
author_facet |
Wei-Chih Hu Chih-Sheng Yeh 葉志盛 |
author |
Chih-Sheng Yeh 葉志盛 |
spellingShingle |
Chih-Sheng Yeh 葉志盛 The Assistance of Tomosynthesis Image Reformation using MATLAB Image Processing Tool-box for Department of Radiology. |
author_sort |
Chih-Sheng Yeh |
title |
The Assistance of Tomosynthesis Image Reformation using MATLAB Image Processing Tool-box for Department of Radiology. |
title_short |
The Assistance of Tomosynthesis Image Reformation using MATLAB Image Processing Tool-box for Department of Radiology. |
title_full |
The Assistance of Tomosynthesis Image Reformation using MATLAB Image Processing Tool-box for Department of Radiology. |
title_fullStr |
The Assistance of Tomosynthesis Image Reformation using MATLAB Image Processing Tool-box for Department of Radiology. |
title_full_unstemmed |
The Assistance of Tomosynthesis Image Reformation using MATLAB Image Processing Tool-box for Department of Radiology. |
title_sort |
assistance of tomosynthesis image reformation using matlab image processing tool-box for department of radiology. |
publishDate |
2011 |
url |
http://ndltd.ncl.edu.tw/handle/88936739532588451219 |
work_keys_str_mv |
AT chihshengyeh theassistanceoftomosynthesisimagereformationusingmatlabimageprocessingtoolboxfordepartmentofradiology AT yèzhìshèng theassistanceoftomosynthesisimagereformationusingmatlabimageprocessingtoolboxfordepartmentofradiology AT chihshengyeh lìyòngmatlabyǐngxiàngchùlǐgōngjùhézhòngzǔduàncéngcéngxīyǐngxiàngduìyǐngxiàngzhěnliáokēdefǔzhù AT yèzhìshèng lìyòngmatlabyǐngxiàngchùlǐgōngjùhézhòngzǔduàncéngcéngxīyǐngxiàngduìyǐngxiàngzhěnliáokēdefǔzhù AT chihshengyeh assistanceoftomosynthesisimagereformationusingmatlabimageprocessingtoolboxfordepartmentofradiology AT yèzhìshèng assistanceoftomosynthesisimagereformationusingmatlabimageprocessingtoolboxfordepartmentofradiology |
_version_ |
1718047222976741376 |