Online Monitoring of Fouling Layer Thickness Variation in Membrane Filter for High Turbidity Influent Treatment Using Photo-interrupt Sensor
碩士 === 中原大學 === 化學工程研究所 === 99 === Membrane fouling is an unfavorable but inevitable problem in membrane filtration process. Online monitoring techniques can play a major role in understanding its formation mechanism and this may helpful to accomplish a better control over reduction of membrane foul...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
2011
|
Online Access: | http://ndltd.ncl.edu.tw/handle/21818224202401787550 |
id |
ndltd-TW-099CYCU5063007 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099CYCU50630072015-10-30T04:05:39Z http://ndltd.ncl.edu.tw/handle/21818224202401787550 Online Monitoring of Fouling Layer Thickness Variation in Membrane Filter for High Turbidity Influent Treatment Using Photo-interrupt Sensor 以光學探針法線上監測高濁度進水 薄膜過濾之污塞層厚度變化之研究 Hemlata-Rahul Damodar 戴牧恬 碩士 中原大學 化學工程研究所 99 Membrane fouling is an unfavorable but inevitable problem in membrane filtration process. Online monitoring techniques can play a major role in understanding its formation mechanism and this may helpful to accomplish a better control over reduction of membrane fouling. Numerous destructive and non-destructive experimental methods were developed for the direct and indirect measurement of cake layer thickness. The present study describes an application of an in-situ optical method to determine the growth of fouling layer by using photo-interrupt sensor. This technique can be effectively used to non-destructively measure or monitor cake thickness as a function of time. In order to verify the validity of this method, the effect of voltage (10 – 12 V), slurry concentration (0 – 2 g/L), and membrane material (PVDF and PTFE) on sensor signal were examined. In addition, the application of this method for monitoring the growth of fouling cake layer thickness during filtration of high turbidity wastewater under different conditions of flux (50 – 200 LMH), aeration (continuous and semi-continuous at 1 – 1.5 L/min) and suction (continuous and semi-continuous) were studied. The Degussa P25 TiO2 particles were selected for filtration and calibration experiments. Results showed that as TiO2 particle concentration increases the slope of sensor calibration plot decreases. As input voltage increase from 10 to 12V, results showed that the calibration curve attends more linearity and increased sensitivity at all TiO2 concentration. It was also observed that the sensor signal (voltage) fluctuation at 12V and at higher concentration of TiO2 particles (>1.5 g/L) was higher than that at 10V. The PTFE membrane showed better sensitivity as compared to PVDF membrane. From the filtration experiment it was observed that at lower flux the fouling is more at the bottom than at the top of the membrane. But as the flux increases the cake layer become more and more uniform. It was also observed that TMP rise was not so severe at low flux due to low and irregular fouling. But at high flux the TMP increases rapidly and attends a constant value. The cake thickness around entire surface area of the membrane was suppressed due to continuous aeration. The semi-continuous aeration could also suppress the membrane fouling at the same level as observed at continuous aeration. The combination of suction and relaxation at different conditions can only reduces the growth rate of fouling cake layer thickness, but extent fouling was not suppressed. The application of suction and backflow mode with sufficient backflow period conditions can suppress the fouling drastically to the same extent that observed during semi-continuous aeration condition. Kuo-Lun Tung 童國倫 2011 學位論文 ; thesis 150 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中原大學 === 化學工程研究所 === 99 === Membrane fouling is an unfavorable but inevitable problem in membrane filtration process. Online monitoring techniques can play a major role in understanding its formation mechanism and this may helpful to accomplish a better control over reduction of membrane fouling. Numerous destructive and non-destructive experimental methods were developed for the direct and indirect measurement of cake layer thickness. The present study describes an application of an in-situ optical method to determine the growth of fouling layer by using photo-interrupt sensor. This technique can be effectively used to non-destructively measure or monitor cake thickness as a function of time.
In order to verify the validity of this method, the effect of voltage (10 – 12 V), slurry concentration (0 – 2 g/L), and membrane material (PVDF and PTFE) on sensor signal were examined. In addition, the application of this method for monitoring the growth of fouling cake layer thickness during filtration of high turbidity wastewater under different conditions of flux (50 – 200 LMH), aeration (continuous and semi-continuous at 1 – 1.5 L/min) and suction (continuous and semi-continuous) were studied. The Degussa P25 TiO2 particles were selected for filtration and calibration experiments.
Results showed that as TiO2 particle concentration increases the slope of sensor calibration plot decreases. As input voltage increase from 10 to 12V, results showed that the calibration curve attends more linearity and increased sensitivity at all TiO2 concentration. It was also observed that the sensor signal (voltage) fluctuation at 12V and at higher concentration of TiO2 particles (>1.5 g/L) was higher than that at 10V. The PTFE membrane showed better sensitivity as compared to PVDF membrane.
From the filtration experiment it was observed that at lower flux the fouling is more at the bottom than at the top of the membrane. But as the flux increases the cake layer become more and more uniform. It was also observed that TMP rise was not so severe at low flux due to low and irregular fouling. But at high flux the TMP increases rapidly and attends a constant value. The cake thickness around entire surface area of the membrane was suppressed due to continuous aeration. The semi-continuous aeration could also suppress the membrane fouling at the same level as observed at continuous aeration. The combination of suction and relaxation at different conditions can only reduces the growth rate of fouling cake layer thickness, but extent fouling was not suppressed. The application of suction and backflow mode with sufficient backflow period conditions can suppress the fouling drastically to the same extent that observed during semi-continuous aeration condition.
|
author2 |
Kuo-Lun Tung |
author_facet |
Kuo-Lun Tung Hemlata-Rahul Damodar 戴牧恬 |
author |
Hemlata-Rahul Damodar 戴牧恬 |
spellingShingle |
Hemlata-Rahul Damodar 戴牧恬 Online Monitoring of Fouling Layer Thickness Variation in Membrane Filter for High Turbidity Influent Treatment Using Photo-interrupt Sensor |
author_sort |
Hemlata-Rahul Damodar |
title |
Online Monitoring of Fouling Layer Thickness Variation in Membrane Filter for High Turbidity Influent Treatment Using Photo-interrupt Sensor |
title_short |
Online Monitoring of Fouling Layer Thickness Variation in Membrane Filter for High Turbidity Influent Treatment Using Photo-interrupt Sensor |
title_full |
Online Monitoring of Fouling Layer Thickness Variation in Membrane Filter for High Turbidity Influent Treatment Using Photo-interrupt Sensor |
title_fullStr |
Online Monitoring of Fouling Layer Thickness Variation in Membrane Filter for High Turbidity Influent Treatment Using Photo-interrupt Sensor |
title_full_unstemmed |
Online Monitoring of Fouling Layer Thickness Variation in Membrane Filter for High Turbidity Influent Treatment Using Photo-interrupt Sensor |
title_sort |
online monitoring of fouling layer thickness variation in membrane filter for high turbidity influent treatment using photo-interrupt sensor |
publishDate |
2011 |
url |
http://ndltd.ncl.edu.tw/handle/21818224202401787550 |
work_keys_str_mv |
AT hemlatarahuldamodar onlinemonitoringoffoulinglayerthicknessvariationinmembranefilterforhighturbidityinfluenttreatmentusingphotointerruptsensor AT dàimùtián onlinemonitoringoffoulinglayerthicknessvariationinmembranefilterforhighturbidityinfluenttreatmentusingphotointerruptsensor AT hemlatarahuldamodar yǐguāngxuétànzhēnfǎxiànshàngjiāncègāozhuódùjìnshuǐbáomóguòlǜzhīwūsāicénghòudùbiànhuàzhīyánjiū AT dàimùtián yǐguāngxuétànzhēnfǎxiànshàngjiāncègāozhuódùjìnshuǐbáomóguòlǜzhīwūsāicénghòudùbiànhuàzhīyánjiū |
_version_ |
1718116228323606528 |