The Study on Using Water Mist System for Wind Generator Fire Protection
碩士 === 中臺科技大學 === 安全與防災科技研究所 === 99 === Through extensive research and testing, water mist systems have gained worldwide acceptance as an effective solution in many applications, such as those that involve flammable liquids, electrical equipment, semiconductor facilities, and outdoor transformers. T...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2011
|
Online Access: | http://ndltd.ncl.edu.tw/handle/41501325600497241547 |
id |
ndltd-TW-099CTC05707005 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-099CTC057070052015-10-19T04:03:42Z http://ndltd.ncl.edu.tw/handle/41501325600497241547 The Study on Using Water Mist System for Wind Generator Fire Protection 細水霧系統運用於大型風力發電機火災防護之有效性評估 Li-Xiang Cai 蔡立祥 碩士 中臺科技大學 安全與防災科技研究所 99 Through extensive research and testing, water mist systems have gained worldwide acceptance as an effective solution in many applications, such as those that involve flammable liquids, electrical equipment, semiconductor facilities, and outdoor transformers. The NFPA 750 standard defines “water mist” as a water spray discharged through a nozzle in which 99% of the water spray’s volume comprises water particles less than 1,000 microns in diameter. A water mist system combines the key suppression mechanisms of heat absorption, oxygen displacement and radiant heat blocking to control, suppress and extinguish fires. In addition, water mist systems provide the following advantages over other systems: superior fire suppression, smoke absorption capability, minimal water damage, non-toxicity, non-asphyxiating, and environmentally friendly. Wind generators have become very popular lately as a means to generate power for today’s life. The height of wind generator is always 60 to 70 meters. If the cabinet is in fire, it will be hard to response for fire fighter. A fixed fire suppression system is a good solution for fire protection. For the good performance of water mist system, this study wants to develop a water mist system for wind generator fire protection. Through series of fire tests, the water mist system is proofed to have good effectiveness on fire suppression in wind generator fire. Yi-Liang Shu 徐一量 2011 學位論文 ; thesis 123 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中臺科技大學 === 安全與防災科技研究所 === 99 === Through extensive research and testing, water mist systems have gained worldwide acceptance as an effective solution in many applications, such as those that involve flammable liquids, electrical equipment, semiconductor facilities, and outdoor transformers. The NFPA 750 standard defines “water mist” as a water spray discharged through a nozzle in which 99% of the water spray’s volume comprises water particles less than 1,000 microns in diameter. A water mist system combines the key suppression mechanisms of heat absorption, oxygen displacement and radiant heat blocking to control, suppress and extinguish fires. In addition, water mist systems provide the following advantages over other systems: superior fire suppression, smoke absorption capability, minimal water damage, non-toxicity, non-asphyxiating, and environmentally friendly.
Wind generators have become very popular lately as a means to generate power for today’s life. The height of wind generator is always 60 to 70 meters. If the cabinet is in fire, it will be hard to response for fire fighter. A fixed fire suppression system is a good solution for fire protection. For the good performance of water mist system, this study wants to develop a water mist system for wind generator fire protection. Through series of fire tests, the water mist system is proofed to have good effectiveness on fire suppression in wind generator fire.
|
author2 |
Yi-Liang Shu |
author_facet |
Yi-Liang Shu Li-Xiang Cai 蔡立祥 |
author |
Li-Xiang Cai 蔡立祥 |
spellingShingle |
Li-Xiang Cai 蔡立祥 The Study on Using Water Mist System for Wind Generator Fire Protection |
author_sort |
Li-Xiang Cai |
title |
The Study on Using Water Mist System for Wind Generator Fire Protection |
title_short |
The Study on Using Water Mist System for Wind Generator Fire Protection |
title_full |
The Study on Using Water Mist System for Wind Generator Fire Protection |
title_fullStr |
The Study on Using Water Mist System for Wind Generator Fire Protection |
title_full_unstemmed |
The Study on Using Water Mist System for Wind Generator Fire Protection |
title_sort |
study on using water mist system for wind generator fire protection |
publishDate |
2011 |
url |
http://ndltd.ncl.edu.tw/handle/41501325600497241547 |
work_keys_str_mv |
AT lixiangcai thestudyonusingwatermistsystemforwindgeneratorfireprotection AT càilìxiáng thestudyonusingwatermistsystemforwindgeneratorfireprotection AT lixiangcai xìshuǐwùxìtǒngyùnyòngyúdàxíngfēnglìfādiànjīhuǒzāifánghùzhīyǒuxiàoxìngpínggū AT càilìxiáng xìshuǐwùxìtǒngyùnyòngyúdàxíngfēnglìfādiànjīhuǒzāifánghùzhīyǒuxiàoxìngpínggū AT lixiangcai studyonusingwatermistsystemforwindgeneratorfireprotection AT càilìxiáng studyonusingwatermistsystemforwindgeneratorfireprotection |
_version_ |
1718094348980060160 |