The Study on Using Water Mist System for Wind Generator Fire Protection

碩士 === 中臺科技大學 === 安全與防災科技研究所 === 99 === Through extensive research and testing, water mist systems have gained worldwide acceptance as an effective solution in many applications, such as those that involve flammable liquids, electrical equipment, semiconductor facilities, and outdoor transformers. T...

Full description

Bibliographic Details
Main Authors: Li-Xiang Cai, 蔡立祥
Other Authors: Yi-Liang Shu
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/41501325600497241547
id ndltd-TW-099CTC05707005
record_format oai_dc
spelling ndltd-TW-099CTC057070052015-10-19T04:03:42Z http://ndltd.ncl.edu.tw/handle/41501325600497241547 The Study on Using Water Mist System for Wind Generator Fire Protection 細水霧系統運用於大型風力發電機火災防護之有效性評估 Li-Xiang Cai 蔡立祥 碩士 中臺科技大學 安全與防災科技研究所 99 Through extensive research and testing, water mist systems have gained worldwide acceptance as an effective solution in many applications, such as those that involve flammable liquids, electrical equipment, semiconductor facilities, and outdoor transformers. The NFPA 750 standard defines “water mist” as a water spray discharged through a nozzle in which 99% of the water spray’s volume comprises water particles less than 1,000 microns in diameter. A water mist system combines the key suppression mechanisms of heat absorption, oxygen displacement and radiant heat blocking to control, suppress and extinguish fires. In addition, water mist systems provide the following advantages over other systems: superior fire suppression, smoke absorption capability, minimal water damage, non-toxicity, non-asphyxiating, and environmentally friendly. Wind generators have become very popular lately as a means to generate power for today’s life. The height of wind generator is always 60 to 70 meters. If the cabinet is in fire, it will be hard to response for fire fighter. A fixed fire suppression system is a good solution for fire protection. For the good performance of water mist system, this study wants to develop a water mist system for wind generator fire protection. Through series of fire tests, the water mist system is proofed to have good effectiveness on fire suppression in wind generator fire. Yi-Liang Shu 徐一量 2011 學位論文 ; thesis 123 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中臺科技大學 === 安全與防災科技研究所 === 99 === Through extensive research and testing, water mist systems have gained worldwide acceptance as an effective solution in many applications, such as those that involve flammable liquids, electrical equipment, semiconductor facilities, and outdoor transformers. The NFPA 750 standard defines “water mist” as a water spray discharged through a nozzle in which 99% of the water spray’s volume comprises water particles less than 1,000 microns in diameter. A water mist system combines the key suppression mechanisms of heat absorption, oxygen displacement and radiant heat blocking to control, suppress and extinguish fires. In addition, water mist systems provide the following advantages over other systems: superior fire suppression, smoke absorption capability, minimal water damage, non-toxicity, non-asphyxiating, and environmentally friendly. Wind generators have become very popular lately as a means to generate power for today’s life. The height of wind generator is always 60 to 70 meters. If the cabinet is in fire, it will be hard to response for fire fighter. A fixed fire suppression system is a good solution for fire protection. For the good performance of water mist system, this study wants to develop a water mist system for wind generator fire protection. Through series of fire tests, the water mist system is proofed to have good effectiveness on fire suppression in wind generator fire.
author2 Yi-Liang Shu
author_facet Yi-Liang Shu
Li-Xiang Cai
蔡立祥
author Li-Xiang Cai
蔡立祥
spellingShingle Li-Xiang Cai
蔡立祥
The Study on Using Water Mist System for Wind Generator Fire Protection
author_sort Li-Xiang Cai
title The Study on Using Water Mist System for Wind Generator Fire Protection
title_short The Study on Using Water Mist System for Wind Generator Fire Protection
title_full The Study on Using Water Mist System for Wind Generator Fire Protection
title_fullStr The Study on Using Water Mist System for Wind Generator Fire Protection
title_full_unstemmed The Study on Using Water Mist System for Wind Generator Fire Protection
title_sort study on using water mist system for wind generator fire protection
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/41501325600497241547
work_keys_str_mv AT lixiangcai thestudyonusingwatermistsystemforwindgeneratorfireprotection
AT càilìxiáng thestudyonusingwatermistsystemforwindgeneratorfireprotection
AT lixiangcai xìshuǐwùxìtǒngyùnyòngyúdàxíngfēnglìfādiànjīhuǒzāifánghùzhīyǒuxiàoxìngpínggū
AT càilìxiáng xìshuǐwùxìtǒngyùnyòngyúdàxíngfēnglìfādiànjīhuǒzāifánghùzhīyǒuxiàoxìngpínggū
AT lixiangcai studyonusingwatermistsystemforwindgeneratorfireprotection
AT càilìxiáng studyonusingwatermistsystemforwindgeneratorfireprotection
_version_ 1718094348980060160