Design and performance analysis of metal bipolar plate on PEMFC stack
碩士 === 元智大學 === 機械工程學系 === 98 === In this study, we used low-cost, lightweight aluminum alloy bipolar plate on proton exchange membrane fuel cell(PEMFC) stack. Aluminum alloy has good heat Thermal conductivity and mechanical strength. But, aluminum alloy surface oxides lead to poor conductivity, hig...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2010
|
Online Access: | http://ndltd.ncl.edu.tw/handle/02834104724980827876 |
id |
ndltd-TW-098YZU05489093 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-098YZU054890932016-03-04T04:15:04Z http://ndltd.ncl.edu.tw/handle/02834104724980827876 Design and performance analysis of metal bipolar plate on PEMFC stack 質子交換膜燃料電池堆金屬雙極板設計與性能分析 Che-Jung Hsu 許哲榮 碩士 元智大學 機械工程學系 98 In this study, we used low-cost, lightweight aluminum alloy bipolar plate on proton exchange membrane fuel cell(PEMFC) stack. Aluminum alloy has good heat Thermal conductivity and mechanical strength. But, aluminum alloy surface oxides lead to poor conductivity, high contact resistance. So we using Au-coated on aluminum alloy bipolar plate surface. Assembled into a single cell and 4-cells stack to measure performance. At H2/Air stoichimotry 1.2/4.0 and humidification temperature of 60 ℃ for best performance by single cell 61.6W and stack maximum power 286W. The dynamic load test had a good response. Finally, the metal bipolar plate to set a long-term test to ensure the stability of the single cell output is no recession. AySu 蘇艾 2010 學位論文 ; thesis 77 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 元智大學 === 機械工程學系 === 98 === In this study, we used low-cost, lightweight aluminum alloy bipolar plate on proton exchange membrane fuel cell(PEMFC) stack. Aluminum alloy has good heat Thermal conductivity and mechanical strength. But, aluminum alloy surface oxides lead to poor conductivity, high contact resistance. So we using Au-coated on aluminum alloy bipolar plate surface. Assembled into a single cell and 4-cells stack to measure performance. At H2/Air stoichimotry 1.2/4.0 and humidification temperature of 60 ℃ for best performance by single cell 61.6W and stack maximum power 286W. The dynamic load test had a good response. Finally, the metal bipolar plate to set a long-term test to ensure the stability of the single cell output is no recession.
|
author2 |
AySu |
author_facet |
AySu Che-Jung Hsu 許哲榮 |
author |
Che-Jung Hsu 許哲榮 |
spellingShingle |
Che-Jung Hsu 許哲榮 Design and performance analysis of metal bipolar plate on PEMFC stack |
author_sort |
Che-Jung Hsu |
title |
Design and performance analysis of metal bipolar plate on PEMFC stack |
title_short |
Design and performance analysis of metal bipolar plate on PEMFC stack |
title_full |
Design and performance analysis of metal bipolar plate on PEMFC stack |
title_fullStr |
Design and performance analysis of metal bipolar plate on PEMFC stack |
title_full_unstemmed |
Design and performance analysis of metal bipolar plate on PEMFC stack |
title_sort |
design and performance analysis of metal bipolar plate on pemfc stack |
publishDate |
2010 |
url |
http://ndltd.ncl.edu.tw/handle/02834104724980827876 |
work_keys_str_mv |
AT chejunghsu designandperformanceanalysisofmetalbipolarplateonpemfcstack AT xǔzhéróng designandperformanceanalysisofmetalbipolarplateonpemfcstack AT chejunghsu zhìzijiāohuànmóránliàodiànchíduījīnshǔshuāngjíbǎnshèjìyǔxìngnéngfēnxī AT xǔzhéróng zhìzijiāohuànmóránliàodiànchíduījīnshǔshuāngjíbǎnshèjìyǔxìngnéngfēnxī |
_version_ |
1718198888813297664 |