The study of a STROKE-GUARDIAN with wireless wearable multiple physiological sensors
碩士 === 國立臺北科技大學 === 電資碩士班 === 98 === Stroke not only influence patient himself, this will indeed reduces the life quality of the patient’s family. How to lower the probability of patients'' worsening conditions and to promote the better quality of the patient’s family are our major...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2010
|
Online Access: | http://ndltd.ncl.edu.tw/handle/9xn6h4 |
id |
ndltd-TW-098TIT05706006 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-098TIT057060062019-05-15T20:33:24Z http://ndltd.ncl.edu.tw/handle/9xn6h4 The study of a STROKE-GUARDIAN with wireless wearable multiple physiological sensors 具無線可穿戴式多生醫感測器之中風患者守護神研究 Chin-Yao Lee 李景堯 碩士 國立臺北科技大學 電資碩士班 98 Stroke not only influence patient himself, this will indeed reduces the life quality of the patient’s family. How to lower the probability of patients'' worsening conditions and to promote the better quality of the patient’s family are our major subjects of this study. We propose the “STROKE-GUARDIAN Rehabilitation Device” mechanism, which is to integrate the wireless sensor network (WSN) and wearable multiple physiological sensors and then apply to the stroke rehabilitation. “GUARDIAN” can automatically record the bio-information of the stroke’s daily life such that our system can send out the alarm information to those care persons when there is an abnormal condition. Hence, those medical care persons can make the proper response for lowering the probability of patients'' worsening conditions. Moreover, the patients'' member can understand and monitor the stroke’s newest information by the tele-care to make the proper action such that they can promote their life quality. In our system, the wearable electrodes can be employed to detect the ECG and heart rate from the stroke. Then, the temperature and respiration sensor can be sewed within the wearable vita-bent and then detect the body temperature and the amount of respiration, respectively. Finally, the accelerometer sensor and gyroscope sensor within our system can detect correctly whether the stroke falls down or not. All bio-information of the stroke’ daily life can be transmitted to the data collector by WSN, and then the authorized users can show all information by their browser with the graphic interface. 黃文增 2010 學位論文 ; thesis 94 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺北科技大學 === 電資碩士班 === 98 === Stroke not only influence patient himself, this will indeed reduces the life quality of the patient’s family. How to lower the probability of patients'' worsening conditions and to promote the better quality of the patient’s family are our major subjects of this study. We propose the “STROKE-GUARDIAN Rehabilitation Device” mechanism, which is to integrate the wireless sensor network (WSN) and wearable multiple physiological sensors and then apply to the stroke rehabilitation. “GUARDIAN” can automatically record the bio-information of the stroke’s daily life such that our system can send out the alarm information to those care persons when there is an abnormal condition. Hence, those medical care persons can make the proper response for lowering the probability of patients'' worsening conditions. Moreover, the patients'' member can understand and monitor the stroke’s newest information by the tele-care to
make the proper action such that they can promote their life quality. In our system, the wearable electrodes can be employed to detect the ECG and heart rate from the stroke.
Then, the temperature and respiration sensor can be sewed within the wearable vita-bent and then detect the body temperature and the amount of respiration, respectively.
Finally, the accelerometer sensor and gyroscope sensor within our system can detect correctly whether the stroke falls down or not. All bio-information of the stroke’ daily
life can be transmitted to the data collector by WSN, and then the authorized users can show all information by their browser with the graphic interface.
|
author2 |
黃文增 |
author_facet |
黃文增 Chin-Yao Lee 李景堯 |
author |
Chin-Yao Lee 李景堯 |
spellingShingle |
Chin-Yao Lee 李景堯 The study of a STROKE-GUARDIAN with wireless wearable multiple physiological sensors |
author_sort |
Chin-Yao Lee |
title |
The study of a STROKE-GUARDIAN with wireless wearable multiple physiological sensors |
title_short |
The study of a STROKE-GUARDIAN with wireless wearable multiple physiological sensors |
title_full |
The study of a STROKE-GUARDIAN with wireless wearable multiple physiological sensors |
title_fullStr |
The study of a STROKE-GUARDIAN with wireless wearable multiple physiological sensors |
title_full_unstemmed |
The study of a STROKE-GUARDIAN with wireless wearable multiple physiological sensors |
title_sort |
study of a stroke-guardian with wireless wearable multiple physiological sensors |
publishDate |
2010 |
url |
http://ndltd.ncl.edu.tw/handle/9xn6h4 |
work_keys_str_mv |
AT chinyaolee thestudyofastrokeguardianwithwirelesswearablemultiplephysiologicalsensors AT lǐjǐngyáo thestudyofastrokeguardianwithwirelesswearablemultiplephysiologicalsensors AT chinyaolee jùwúxiànkěchuāndàishìduōshēngyīgǎncèqìzhīzhōngfēnghuànzhěshǒuhùshényánjiū AT lǐjǐngyáo jùwúxiànkěchuāndàishìduōshēngyīgǎncèqìzhīzhōngfēnghuànzhěshǒuhùshényánjiū AT chinyaolee studyofastrokeguardianwithwirelesswearablemultiplephysiologicalsensors AT lǐjǐngyáo studyofastrokeguardianwithwirelesswearablemultiplephysiologicalsensors |
_version_ |
1719100739707469824 |