A Research on an innovation high performance closed type data center service cabinet

碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 98 === Closed type server cabinets are supplied with cool air so that the servers can draw cool air for maintaining proper heat rejection. As the result of intensive energy consumption, IDC has consumed more power than television sets in the United States. In fu...

Full description

Bibliographic Details
Main Authors: Yan-Chang Chen, 陳彥昌
Other Authors: 蔡尤溪
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/c59jfe
id ndltd-TW-098TIT05703092
record_format oai_dc
spelling ndltd-TW-098TIT057030922019-05-15T20:33:26Z http://ndltd.ncl.edu.tw/handle/c59jfe A Research on an innovation high performance closed type data center service cabinet 創新資料中心高性能密閉式機櫃研究 Yan-Chang Chen 陳彥昌 碩士 國立臺北科技大學 能源與冷凍空調工程系碩士班 98 Closed type server cabinets are supplied with cool air so that the servers can draw cool air for maintaining proper heat rejection. As the result of intensive energy consumption, IDC has consumed more power than television sets in the United States. In future cloud computing would only cause IDC to become a major energy use in developed nations. This study investigated the horizontal blade servers and rack servers closed when the heat applied to comparative performance, and to computational fluid dynamics software (FLUENT) to establish closed cabinet of 3D model to numerical simulation of flow field and temperature cabinet. The parameters studied were: (1) cabinet air entrance holes, (2) variable air volume of the cabinet, (3) The return flow of heat. Change the air flow through the entrance hole in the cabinet, when the cabinet air flow entrance and the entrance ipsilateral server, the server will result in the decline of the air temperature rise and exports. Changing the variable air volume of the cabinet, the cabinet out to improve air flow would reduce the amount of servers and increase the primary air fan energy. It was found to enhance the fan cabinet fan noise caused by wind along larger. Blade closed cabinet design, the server can be compared to horizontal to accommodate more servers, rack heat load when the blade reached 3.334kW, its blade server rack the average exit temperature of 307.7K (34.7 ℃), 2kW heat load at the time, its blade server exit temperature is 304.9K (31.9 ℃), the average temperature rose by only 2.8K, can be seen blade servers in the parameter optimization, additional heat inside the cabinet load, and heat dissipation without sacrificing server performance. 蔡尤溪 2010 學位論文 ; thesis 159 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 98 === Closed type server cabinets are supplied with cool air so that the servers can draw cool air for maintaining proper heat rejection. As the result of intensive energy consumption, IDC has consumed more power than television sets in the United States. In future cloud computing would only cause IDC to become a major energy use in developed nations. This study investigated the horizontal blade servers and rack servers closed when the heat applied to comparative performance, and to computational fluid dynamics software (FLUENT) to establish closed cabinet of 3D model to numerical simulation of flow field and temperature cabinet. The parameters studied were: (1) cabinet air entrance holes, (2) variable air volume of the cabinet, (3) The return flow of heat. Change the air flow through the entrance hole in the cabinet, when the cabinet air flow entrance and the entrance ipsilateral server, the server will result in the decline of the air temperature rise and exports. Changing the variable air volume of the cabinet, the cabinet out to improve air flow would reduce the amount of servers and increase the primary air fan energy. It was found to enhance the fan cabinet fan noise caused by wind along larger. Blade closed cabinet design, the server can be compared to horizontal to accommodate more servers, rack heat load when the blade reached 3.334kW, its blade server rack the average exit temperature of 307.7K (34.7 ℃), 2kW heat load at the time, its blade server exit temperature is 304.9K (31.9 ℃), the average temperature rose by only 2.8K, can be seen blade servers in the parameter optimization, additional heat inside the cabinet load, and heat dissipation without sacrificing server performance.
author2 蔡尤溪
author_facet 蔡尤溪
Yan-Chang Chen
陳彥昌
author Yan-Chang Chen
陳彥昌
spellingShingle Yan-Chang Chen
陳彥昌
A Research on an innovation high performance closed type data center service cabinet
author_sort Yan-Chang Chen
title A Research on an innovation high performance closed type data center service cabinet
title_short A Research on an innovation high performance closed type data center service cabinet
title_full A Research on an innovation high performance closed type data center service cabinet
title_fullStr A Research on an innovation high performance closed type data center service cabinet
title_full_unstemmed A Research on an innovation high performance closed type data center service cabinet
title_sort research on an innovation high performance closed type data center service cabinet
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/c59jfe
work_keys_str_mv AT yanchangchen aresearchonaninnovationhighperformanceclosedtypedatacenterservicecabinet
AT chényànchāng aresearchonaninnovationhighperformanceclosedtypedatacenterservicecabinet
AT yanchangchen chuàngxīnzīliàozhōngxīngāoxìngnéngmìbìshìjīguìyánjiū
AT chényànchāng chuàngxīnzīliàozhōngxīngāoxìngnéngmìbìshìjīguìyánjiū
AT yanchangchen researchonaninnovationhighperformanceclosedtypedatacenterservicecabinet
AT chényànchāng researchonaninnovationhighperformanceclosedtypedatacenterservicecabinet
_version_ 1719101560413224960