Measuring & Application of a Surface-type Thermocouple

碩士 === 國立臺北科技大學 === 機電整合研究所 === 98 === Temperature measuring is the basis of various measurements. Thermocouple is a widely used device for measuring temperature with various forms of sensing elements on one end, such as slice type, coil type, roller type, board type, and magnetic type, etc. There a...

Full description

Bibliographic Details
Main Authors: Yi-Hsun Lin, 林宜勳
Other Authors: 韓麗龍
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/yc88bf
id ndltd-TW-098TIT05651005
record_format oai_dc
spelling ndltd-TW-098TIT056510052019-05-15T20:33:23Z http://ndltd.ncl.edu.tw/handle/yc88bf Measuring & Application of a Surface-type Thermocouple 表面型熱電偶之量測與應用 Yi-Hsun Lin 林宜勳 碩士 國立臺北科技大學 機電整合研究所 98 Temperature measuring is the basis of various measurements. Thermocouple is a widely used device for measuring temperature with various forms of sensing elements on one end, such as slice type, coil type, roller type, board type, and magnetic type, etc. There are 9 calibration types --- K, E, J, T, R, B, S, N, and C --- for thermocouple wire and compensation wire. This research focuses on the measuring error and response rate of surface-type thermocouples (K type) including the correct measuring methods, the types of welding joint type, the dimensions of thermocouple wire (width and thickness), and the types of sensing elements (single slice type, triple slice type, coil type, and roller type). Study results show: (1) the accuracy and response rate are not influenced by the types of welding joint. (2) the dimensions (width and thickness) of thermocouple wire is irrelevant to the accuracy, but is relevant to the response rate: the narrower or the thinner, the quicker. (3) both single slice type and triple slice type can precisely measure the temperature, however, single slice type may result in deviation from testing point and inaccuracy because of the worker’s inappropriate operation. The triple slice type will not, in view of the extra support from the both slices next to the sensing one. (4) coil type is slower than that of slice type on response rate, but coil type can endure higher temperature, be more flexible, last longer, and apply on the rugged surface. (5) roller type responses faster when is applied on rolling surface than on static status, but friction coefficient needs to be taken into consideration for accuracy. 韓麗龍 2010 學位論文 ; thesis 63 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 機電整合研究所 === 98 === Temperature measuring is the basis of various measurements. Thermocouple is a widely used device for measuring temperature with various forms of sensing elements on one end, such as slice type, coil type, roller type, board type, and magnetic type, etc. There are 9 calibration types --- K, E, J, T, R, B, S, N, and C --- for thermocouple wire and compensation wire. This research focuses on the measuring error and response rate of surface-type thermocouples (K type) including the correct measuring methods, the types of welding joint type, the dimensions of thermocouple wire (width and thickness), and the types of sensing elements (single slice type, triple slice type, coil type, and roller type). Study results show: (1) the accuracy and response rate are not influenced by the types of welding joint. (2) the dimensions (width and thickness) of thermocouple wire is irrelevant to the accuracy, but is relevant to the response rate: the narrower or the thinner, the quicker. (3) both single slice type and triple slice type can precisely measure the temperature, however, single slice type may result in deviation from testing point and inaccuracy because of the worker’s inappropriate operation. The triple slice type will not, in view of the extra support from the both slices next to the sensing one. (4) coil type is slower than that of slice type on response rate, but coil type can endure higher temperature, be more flexible, last longer, and apply on the rugged surface. (5) roller type responses faster when is applied on rolling surface than on static status, but friction coefficient needs to be taken into consideration for accuracy.
author2 韓麗龍
author_facet 韓麗龍
Yi-Hsun Lin
林宜勳
author Yi-Hsun Lin
林宜勳
spellingShingle Yi-Hsun Lin
林宜勳
Measuring & Application of a Surface-type Thermocouple
author_sort Yi-Hsun Lin
title Measuring & Application of a Surface-type Thermocouple
title_short Measuring & Application of a Surface-type Thermocouple
title_full Measuring & Application of a Surface-type Thermocouple
title_fullStr Measuring & Application of a Surface-type Thermocouple
title_full_unstemmed Measuring & Application of a Surface-type Thermocouple
title_sort measuring & application of a surface-type thermocouple
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/yc88bf
work_keys_str_mv AT yihsunlin measuringapplicationofasurfacetypethermocouple
AT línyíxūn measuringapplicationofasurfacetypethermocouple
AT yihsunlin biǎomiànxíngrèdiànǒuzhīliàngcèyǔyīngyòng
AT línyíxūn biǎomiànxíngrèdiànǒuzhīliàngcèyǔyīngyòng
_version_ 1719100616472526848