Analysis of Urinary Markers for Toluene Exposure by LC-MS/MS with a New Liquid-Liquid-Liquid Extraction (LLLE) Device

碩士 === 國立虎尾科技大學 === 光電與材料科技研究所 === 98 === Toluene is a widely used solvent in industry. It is a human central nervous system depressant. Long-term exposure of toluene is associated with liver and kidney damage in humans. Bio-monitoring of low level toluene exposure is commonly performed by determina...

Full description

Bibliographic Details
Main Authors: Li-Jun Huang, 黃豊鈞
Other Authors: 沈振峯
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/rf5j2j
id ndltd-TW-098NYPI5124064
record_format oai_dc
spelling ndltd-TW-098NYPI51240642019-09-22T03:40:57Z http://ndltd.ncl.edu.tw/handle/rf5j2j Analysis of Urinary Markers for Toluene Exposure by LC-MS/MS with a New Liquid-Liquid-Liquid Extraction (LLLE) Device 新型三液相萃取裝置結合液相層析串聯質譜儀偵測尿液中甲苯暴露指標成分 Li-Jun Huang 黃豊鈞 碩士 國立虎尾科技大學 光電與材料科技研究所 98 Toluene is a widely used solvent in industry. It is a human central nervous system depressant. Long-term exposure of toluene is associated with liver and kidney damage in humans. Bio-monitoring of low level toluene exposure is commonly performed by determination of urinary benzylmercapturic acid (BMA) and o-cresol. In this study, a new three phase liquid-liquid-liquid extraction (LLLE) device was developed and applied in the analysis of the urinary markers of toluene exposure. The new device was simply constructed with centrifuge tube and sample vials, and it is very easily to operate. Because of the higher buffer contents of the acceptor phase, the APCI mode was chosen for the LC-MS/MS analysis. The mainly applied parameters were urine sample mixed with phosphorate buffer (pH~2, donor layer), 1.5 mL toluene and diethyl ether (1:1, organic layer) and 400μL 0.1 M NaOH(aq) (pH~13, acceptor). After extraction and back-extraction, the urinary markers were cleaned up and enriched in the donor phase. In comparing with unprocess urine sample, after LLLE, the ion signals were increased about 100 times for BMA and about 8 times for o-cresol. Good linearity (r2 > 0.99) was also obtained in the range of 10-1000 ng/mL for both urinary BMA and o-cresol. To reduce the relative matrix effect, 10-fold dilution was needed before LLLE. The obtained RSD values of the markers of 7 lots urine samples were all less than 15% . 沈振峯 2010 學位論文 ; thesis 79 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立虎尾科技大學 === 光電與材料科技研究所 === 98 === Toluene is a widely used solvent in industry. It is a human central nervous system depressant. Long-term exposure of toluene is associated with liver and kidney damage in humans. Bio-monitoring of low level toluene exposure is commonly performed by determination of urinary benzylmercapturic acid (BMA) and o-cresol. In this study, a new three phase liquid-liquid-liquid extraction (LLLE) device was developed and applied in the analysis of the urinary markers of toluene exposure. The new device was simply constructed with centrifuge tube and sample vials, and it is very easily to operate. Because of the higher buffer contents of the acceptor phase, the APCI mode was chosen for the LC-MS/MS analysis. The mainly applied parameters were urine sample mixed with phosphorate buffer (pH~2, donor layer), 1.5 mL toluene and diethyl ether (1:1, organic layer) and 400μL 0.1 M NaOH(aq) (pH~13, acceptor). After extraction and back-extraction, the urinary markers were cleaned up and enriched in the donor phase. In comparing with unprocess urine sample, after LLLE, the ion signals were increased about 100 times for BMA and about 8 times for o-cresol. Good linearity (r2 > 0.99) was also obtained in the range of 10-1000 ng/mL for both urinary BMA and o-cresol. To reduce the relative matrix effect, 10-fold dilution was needed before LLLE. The obtained RSD values of the markers of 7 lots urine samples were all less than 15% .
author2 沈振峯
author_facet 沈振峯
Li-Jun Huang
黃豊鈞
author Li-Jun Huang
黃豊鈞
spellingShingle Li-Jun Huang
黃豊鈞
Analysis of Urinary Markers for Toluene Exposure by LC-MS/MS with a New Liquid-Liquid-Liquid Extraction (LLLE) Device
author_sort Li-Jun Huang
title Analysis of Urinary Markers for Toluene Exposure by LC-MS/MS with a New Liquid-Liquid-Liquid Extraction (LLLE) Device
title_short Analysis of Urinary Markers for Toluene Exposure by LC-MS/MS with a New Liquid-Liquid-Liquid Extraction (LLLE) Device
title_full Analysis of Urinary Markers for Toluene Exposure by LC-MS/MS with a New Liquid-Liquid-Liquid Extraction (LLLE) Device
title_fullStr Analysis of Urinary Markers for Toluene Exposure by LC-MS/MS with a New Liquid-Liquid-Liquid Extraction (LLLE) Device
title_full_unstemmed Analysis of Urinary Markers for Toluene Exposure by LC-MS/MS with a New Liquid-Liquid-Liquid Extraction (LLLE) Device
title_sort analysis of urinary markers for toluene exposure by lc-ms/ms with a new liquid-liquid-liquid extraction (llle) device
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/rf5j2j
work_keys_str_mv AT lijunhuang analysisofurinarymarkersfortolueneexposurebylcmsmswithanewliquidliquidliquidextractionllledevice
AT huánglǐjūn analysisofurinarymarkersfortolueneexposurebylcmsmswithanewliquidliquidliquidextractionllledevice
AT lijunhuang xīnxíngsānyèxiāngcuìqǔzhuāngzhìjiéhéyèxiāngcéngxīchuànliánzhìpǔyízhēncèniàoyèzhōngjiǎběnbàolùzhǐbiāochéngfēn
AT huánglǐjūn xīnxíngsānyèxiāngcuìqǔzhuāngzhìjiéhéyèxiāngcéngxīchuànliánzhìpǔyízhēncèniàoyèzhōngjiǎběnbàolùzhǐbiāochéngfēn
_version_ 1719254320300425216