Real-time Insulation Status Assessment of XLPE Based on Decision Tree Scheme

碩士 === 國立臺灣科技大學 === 電機工程系 === 98 ===   The cross-linked polyethylene(XLPE) is the general insulation materials for underground cable. However, it might break down when the cable start to insulation deterioration and then will cause the economic loss and the damage. To perfectly prevent the damage of...

Full description

Bibliographic Details
Main Authors: CHING-MING CHEN, 陳慶明
Other Authors: Ruay-Nan Wu
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/02198731968571542915
id ndltd-TW-098NTUS5442101
record_format oai_dc
spelling ndltd-TW-098NTUS54421012016-04-22T04:23:47Z http://ndltd.ncl.edu.tw/handle/02198731968571542915 Real-time Insulation Status Assessment of XLPE Based on Decision Tree Scheme 應用決策樹機制於即時性評估交鏈聚乙烯絕緣狀態之研究 CHING-MING CHEN 陳慶明 碩士 國立臺灣科技大學 電機工程系 98   The cross-linked polyethylene(XLPE) is the general insulation materials for underground cable. However, it might break down when the cable start to insulation deterioration and then will cause the economic loss and the damage. To perfectly prevent the damage of underground distributed system, this research set up a set of on line monitoring system of partial discharge(PD) to prevent these damages happened.   This thesis is about the slices test of XLPE and made the high voltage and accelerated deterioration test in high voltage laboratory in NTUST. The next step is that to filter and simplified the signal and going to the data switch and further to use feature extraction methods to figure out the feature data of insulation status. This research uses three kinds of feature data that the characteristics are the high Similarity of district average discharge of each test data and the turning properties of slop curve and the stair rises properties of interval extremum deviation. The final step is to use the decision tree scheme to organize the district average discharge, slope curve and interval extremum deviation three feature data and then find the if-then rules further more to set up the on line insulation state diagnosis rules.   The decision tree consists of six decision nodes and ten leaf nodes. The accuracy of real-time insulation status diagnosis about testing data are 95.6% during early stage of degradation、89.8% during middle stage of degradation and 81.3% during final stage of degradation. Ruay-Nan Wu 吳瑞南 2010 學位論文 ; thesis 69 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電機工程系 === 98 ===   The cross-linked polyethylene(XLPE) is the general insulation materials for underground cable. However, it might break down when the cable start to insulation deterioration and then will cause the economic loss and the damage. To perfectly prevent the damage of underground distributed system, this research set up a set of on line monitoring system of partial discharge(PD) to prevent these damages happened.   This thesis is about the slices test of XLPE and made the high voltage and accelerated deterioration test in high voltage laboratory in NTUST. The next step is that to filter and simplified the signal and going to the data switch and further to use feature extraction methods to figure out the feature data of insulation status. This research uses three kinds of feature data that the characteristics are the high Similarity of district average discharge of each test data and the turning properties of slop curve and the stair rises properties of interval extremum deviation. The final step is to use the decision tree scheme to organize the district average discharge, slope curve and interval extremum deviation three feature data and then find the if-then rules further more to set up the on line insulation state diagnosis rules.   The decision tree consists of six decision nodes and ten leaf nodes. The accuracy of real-time insulation status diagnosis about testing data are 95.6% during early stage of degradation、89.8% during middle stage of degradation and 81.3% during final stage of degradation.
author2 Ruay-Nan Wu
author_facet Ruay-Nan Wu
CHING-MING CHEN
陳慶明
author CHING-MING CHEN
陳慶明
spellingShingle CHING-MING CHEN
陳慶明
Real-time Insulation Status Assessment of XLPE Based on Decision Tree Scheme
author_sort CHING-MING CHEN
title Real-time Insulation Status Assessment of XLPE Based on Decision Tree Scheme
title_short Real-time Insulation Status Assessment of XLPE Based on Decision Tree Scheme
title_full Real-time Insulation Status Assessment of XLPE Based on Decision Tree Scheme
title_fullStr Real-time Insulation Status Assessment of XLPE Based on Decision Tree Scheme
title_full_unstemmed Real-time Insulation Status Assessment of XLPE Based on Decision Tree Scheme
title_sort real-time insulation status assessment of xlpe based on decision tree scheme
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/02198731968571542915
work_keys_str_mv AT chingmingchen realtimeinsulationstatusassessmentofxlpebasedondecisiontreescheme
AT chénqìngmíng realtimeinsulationstatusassessmentofxlpebasedondecisiontreescheme
AT chingmingchen yīngyòngjuécèshùjīzhìyújíshíxìngpínggūjiāoliànjùyǐxījuéyuánzhuàngtàizhīyánjiū
AT chénqìngmíng yīngyòngjuécèshùjīzhìyújíshíxìngpínggūjiāoliànjùyǐxījuéyuánzhuàngtàizhīyánjiū
_version_ 1718231388417687552