Novel Optical Coherence Tomography Probe for Oral Disease Diagnosis
碩士 === 臺灣大學 === 光電工程學研究所 === 98 === In this research, a fiber-based OCT system with a newly 3-D probe was built, which utilized the broadband swept-frequency light source with the central wavelength at 1327 nm and the spectral width at 117 nm. The axial resolution of the OCT system was 7 microns in...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
2010
|
Online Access: | http://ndltd.ncl.edu.tw/handle/88953564643936833915 |
id |
ndltd-TW-098NTU05124043 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-098NTU051240432015-10-13T18:49:39Z http://ndltd.ncl.edu.tw/handle/88953564643936833915 Novel Optical Coherence Tomography Probe for Oral Disease Diagnosis 應用於口腔疾病診斷之新型光學同調斷層掃瞄探頭 Kai-Min Yang 楊凱閔 碩士 臺灣大學 光電工程學研究所 98 In this research, a fiber-based OCT system with a newly 3-D probe was built, which utilized the broadband swept-frequency light source with the central wavelength at 1327 nm and the spectral width at 117 nm. The axial resolution of the OCT system was 7 microns in free space. Its sensitivity was 100 dB. A compact two-axis probe specially designed for the oral cavity scanning was fabricated. The lateral resolution of the system is 10 microns. With this hand-held probe, the in vivo scanning results of human skin and fingernail were obtained. In such scanning, three major layers, including stratum corneum, epidermis, and dermis, could be clearly identified. Beside, the sweat gland in finger tip skin and the structures in fingernail, including nail plate, nail body, and nail root, were observed. The penetration of depth of human skin scanning images was 1.4~1.8 mm. The quasi-3-D image size of human skin scanning of 10 mm × 1.5 mm, composed of ten 2-D images of 6000 A-scan, could be completed in less than 1.8 second. To test the clinical application, in vivo scanning of oral mucosa was performed. In such scanning, two types of oral mucosa, including lining mucosa (lip), including labial mucosa and buccal mucosa, and specialized mucosa (the dorsal surface of tongue) were scanned. In the lining scanning images, three major layers, including epithelium, lamina propria, and submucosa, could be identified. The scanning depth of oral mucosa was 1.8~2 mm. In scanning the images of specialized mucosa, tongue papillae, skeletal muscle and some glands could be observed. This OCT system will be used for clinical diagnosis of oral cancer at the National Taiwan University Hospital. 楊志忠 2010 學位論文 ; thesis 55 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 臺灣大學 === 光電工程學研究所 === 98 === In this research, a fiber-based OCT system with a newly 3-D probe was built, which utilized the broadband swept-frequency light source with the central wavelength at 1327 nm and the spectral width at 117 nm. The axial resolution of the OCT system was 7 microns in free space. Its sensitivity was 100 dB. A compact two-axis probe specially designed for the oral cavity scanning was fabricated. The lateral resolution of the system is 10 microns. With this hand-held probe, the in vivo scanning results of human skin and fingernail were obtained. In such scanning, three major layers, including stratum corneum, epidermis, and dermis, could be clearly identified. Beside, the sweat gland in finger tip skin and the structures in fingernail, including nail plate, nail body, and nail root, were observed. The penetration of depth of human skin scanning images was 1.4~1.8 mm. The quasi-3-D image size of human skin scanning of 10 mm × 1.5 mm, composed of ten 2-D images of 6000 A-scan, could be completed in less than 1.8 second.
To test the clinical application, in vivo scanning of oral mucosa was performed. In such scanning, two types of oral mucosa, including lining mucosa (lip), including labial mucosa and buccal mucosa, and specialized mucosa (the dorsal surface of tongue) were scanned. In the lining scanning images, three major layers, including epithelium, lamina propria, and submucosa, could be identified. The scanning depth of oral mucosa was 1.8~2 mm. In scanning the images of specialized mucosa, tongue papillae, skeletal muscle and some glands could be observed. This OCT system will be used for clinical diagnosis of oral cancer at the National Taiwan University Hospital.
|
author2 |
楊志忠 |
author_facet |
楊志忠 Kai-Min Yang 楊凱閔 |
author |
Kai-Min Yang 楊凱閔 |
spellingShingle |
Kai-Min Yang 楊凱閔 Novel Optical Coherence Tomography Probe for Oral Disease Diagnosis |
author_sort |
Kai-Min Yang |
title |
Novel Optical Coherence Tomography Probe for Oral Disease Diagnosis |
title_short |
Novel Optical Coherence Tomography Probe for Oral Disease Diagnosis |
title_full |
Novel Optical Coherence Tomography Probe for Oral Disease Diagnosis |
title_fullStr |
Novel Optical Coherence Tomography Probe for Oral Disease Diagnosis |
title_full_unstemmed |
Novel Optical Coherence Tomography Probe for Oral Disease Diagnosis |
title_sort |
novel optical coherence tomography probe for oral disease diagnosis |
publishDate |
2010 |
url |
http://ndltd.ncl.edu.tw/handle/88953564643936833915 |
work_keys_str_mv |
AT kaiminyang novelopticalcoherencetomographyprobefororaldiseasediagnosis AT yángkǎimǐn novelopticalcoherencetomographyprobefororaldiseasediagnosis AT kaiminyang yīngyòngyúkǒuqiāngjíbìngzhěnduànzhīxīnxíngguāngxuétóngdiàoduàncéngsǎomiáotàntóu AT yángkǎimǐn yīngyòngyúkǒuqiāngjíbìngzhěnduànzhīxīnxíngguāngxuétóngdiàoduàncéngsǎomiáotàntóu |
_version_ |
1718037403184136192 |