Dynamic Analysis of Emergency Generator Under Motor Loading
碩士 === 國立臺灣海洋大學 === 電機工程學系 === 98 === The main purpose of this paper is to study the dynamic characteristics of the emergency diesel generator in power plant under continuous starting of motor loads. A sample system is used as the study system of which the dynamic mathematical models are built and t...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2010
|
Online Access: | http://ndltd.ncl.edu.tw/handle/30028913090210899275 |
Summary: | 碩士 === 國立臺灣海洋大學 === 電機工程學系 === 98 === The main purpose of this paper is to study the dynamic characteristics of the emergency diesel generator in power plant under continuous starting of motor loads. A sample system is used as the study system of which the dynamic mathematical models are built and the dynamic behaviors are analyzed. The system dynamic responses subject to disturbances are observed under the situations of sequentially adding loads for the emergency diesel generator and then with the installation of static capacitors. It is found after comparative analyses that static capacitors will improve the system dynamic behaviors effectively. The findings of this thesis will provide practical suggestions in facilitating the operation of emergency diesel generators.
|
---|