Study of Disposable Silicon-based Chlorine and Ammonium Micro Ion Sensors
碩士 === 國立中山大學 === 電機工程學系研究所 === 98 === Human blood reflects the health of internal organs and tissues, the constituent can be affected on account of abnormal health status. Moreover, the ion concentration of chloride and ammonium in human blood relates to the functionality of our kidney and liver, w...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2010
|
Online Access: | http://ndltd.ncl.edu.tw/handle/75129845409770524641 |
id |
ndltd-TW-098NSYS5442116 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-098NSYS54421162015-10-13T18:39:47Z http://ndltd.ncl.edu.tw/handle/75129845409770524641 Study of Disposable Silicon-based Chlorine and Ammonium Micro Ion Sensors 可拋棄式矽基微型氯離子與銨離子感測器之研究 Wei-chun Chang 張維峻 碩士 國立中山大學 電機工程學系研究所 98 Human blood reflects the health of internal organs and tissues, the constituent can be affected on account of abnormal health status. Moreover, the ion concentration of chloride and ammonium in human blood relates to the functionality of our kidney and liver, which is one of the most important health indicators. For real-time monitoring and detecting applications, this study uses micro-electromechanical systems (MEMS) surface micromachining process technology to develop an extended-gate field-effect transistors (EGFET), and by combining two different ion-selective membranes (ISM), a disposable silicon-based chloride and ammonium micro ion sensor was fabricated. The main process steps include four photolithography process and two thin film deposition. In order to probe into the influences on modulating three designing parameters: (i) channel width to length ratio; (ii) channel shape; (iii) mixing ratio of the sensing film additives, the size of the sensing area is fixed to 1×1 mm2 while the device is fixed to 6 mm3. In this thesis, the optimization of the development chloride and ammonium micro ion sensors, according to the measuring results from the commercial semiconductor analyzer (Agilent B1500A), when measuring range of 10-1~10-5 mol/L, the sensitivity and linearity for the chlorine ion sensor is 47.5 mV/pCl and 99.13%, as for the ammonium ion sensor are 41.2 mV/pNH4 and 99.28%, the interfering ion selectivity coefficients (log KCl,OH, log KNH ,Na) are -4.71 and 0.53 respectively. I-Yu Huang 黃義佑 2010 學位論文 ; thesis 94 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立中山大學 === 電機工程學系研究所 === 98 === Human blood reflects the health of internal organs and tissues, the constituent can be affected on account of abnormal health status. Moreover, the ion concentration of chloride and ammonium in human blood relates to the functionality of our kidney and liver, which is one of the most important health indicators.
For real-time monitoring and detecting applications, this study uses micro-electromechanical systems (MEMS) surface micromachining process technology to develop an extended-gate field-effect transistors (EGFET), and by combining two different ion-selective membranes (ISM), a disposable silicon-based chloride and ammonium micro ion sensor was fabricated. The main process steps include four photolithography process and two thin film deposition. In order to probe into the influences on modulating three designing parameters: (i) channel width to length ratio; (ii) channel shape; (iii) mixing ratio of the sensing film additives, the size of the sensing area is fixed to 1×1 mm2 while the device is fixed to 6 mm3.
In this thesis, the optimization of the development chloride and ammonium micro ion sensors, according to the measuring results from the commercial semiconductor analyzer (Agilent B1500A), when measuring range of 10-1~10-5 mol/L, the sensitivity and linearity for the chlorine ion sensor is 47.5 mV/pCl and 99.13%, as for the ammonium ion sensor are 41.2 mV/pNH4 and 99.28%, the interfering ion selectivity coefficients (log KCl,OH, log KNH ,Na) are -4.71 and 0.53 respectively.
|
author2 |
I-Yu Huang |
author_facet |
I-Yu Huang Wei-chun Chang 張維峻 |
author |
Wei-chun Chang 張維峻 |
spellingShingle |
Wei-chun Chang 張維峻 Study of Disposable Silicon-based Chlorine and Ammonium Micro Ion Sensors |
author_sort |
Wei-chun Chang |
title |
Study of Disposable Silicon-based Chlorine and Ammonium Micro Ion Sensors |
title_short |
Study of Disposable Silicon-based Chlorine and Ammonium Micro Ion Sensors |
title_full |
Study of Disposable Silicon-based Chlorine and Ammonium Micro Ion Sensors |
title_fullStr |
Study of Disposable Silicon-based Chlorine and Ammonium Micro Ion Sensors |
title_full_unstemmed |
Study of Disposable Silicon-based Chlorine and Ammonium Micro Ion Sensors |
title_sort |
study of disposable silicon-based chlorine and ammonium micro ion sensors |
publishDate |
2010 |
url |
http://ndltd.ncl.edu.tw/handle/75129845409770524641 |
work_keys_str_mv |
AT weichunchang studyofdisposablesiliconbasedchlorineandammoniummicroionsensors AT zhāngwéijùn studyofdisposablesiliconbasedchlorineandammoniummicroionsensors AT weichunchang kěpāoqìshìxìjīwēixínglǜlíziyǔǎnlízigǎncèqìzhīyánjiū AT zhāngwéijùn kěpāoqìshìxìjīwēixínglǜlíziyǔǎnlízigǎncèqìzhīyánjiū |
_version_ |
1718036507964473344 |