A Correlation Study of Electromyography Threshold, Heart Rate Variability Threshold, Ventilation Threshold and 3000m Performance

碩士 === 國立彰化師範大學 === 運動健康研究所 === 98 === Abstract This study aimed to discern the difference of electromyography threshold (EMGT), heart rate variability threshold (HRVT) and ventilation threshold (VT) during graded exercise. In addition, correlation of the three determined thresholds and performance...

Full description

Bibliographic Details
Main Author: 林子揚
Other Authors: 蔡忠昌
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/26026574007956980405
id ndltd-TW-098NCUE5420048
record_format oai_dc
spelling ndltd-TW-098NCUE54200482015-11-04T04:01:43Z http://ndltd.ncl.edu.tw/handle/26026574007956980405 A Correlation Study of Electromyography Threshold, Heart Rate Variability Threshold, Ventilation Threshold and 3000m Performance 漸增式運動中肌電及心律變異閾值與無氧閾值及3000公尺成績相關性之研究 林子揚 碩士 國立彰化師範大學 運動健康研究所 98 Abstract This study aimed to discern the difference of electromyography threshold (EMGT), heart rate variability threshold (HRVT) and ventilation threshold (VT) during graded exercise. In addition, correlation of the three determined thresholds and performance of 3000m and 20m shuttle run test were also examined. 13 healthy college males were recruited to join the experiments. At first, they completed the healthy condition form, consent, and body composition assessment by a bio-impedance analyzer. Later, they were subjected to perform a graded exercise on cycle, started at 50watts (W), increased 25W per minute, and terminated when pedaling rate below 60 rpm. The EMG signal of right thigh, intervals of heart rate, and gas analysis were simultaneously recorded during the test. They executed a 20m shuttle run test and a 3000m run test on separate day, respectively, for evaluating personal aerobic capacity. The data were analyzed by pair t-test and Pearson product-moment correlation coefficient analysis with SPSS 12.0. The level of significance was set at p < 0.05. The results showed that EMGT and HRVT were highly correlated with VT2 (R=0.771, P < 0.05; R=0.829, P < 0.05). Power at EMGT and HRVT were significantly correlated to the performance of the 20m shuttle run test, with R=0.782, 0.658, respectively. Power at EMGT and HRVT are also significantly correlated with the 3000m performance with R=-0.555, -0.701, respectively. According to the results, the EMGT and HRVT could be convenient and appropriate methods for assessing aerobic-anaerobic transition and are helpful for athletes and coaches to determine the anaerobic threshold for manipulating personal training protocol. 蔡忠昌 2010 學位論文 ; thesis 65 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立彰化師範大學 === 運動健康研究所 === 98 === Abstract This study aimed to discern the difference of electromyography threshold (EMGT), heart rate variability threshold (HRVT) and ventilation threshold (VT) during graded exercise. In addition, correlation of the three determined thresholds and performance of 3000m and 20m shuttle run test were also examined. 13 healthy college males were recruited to join the experiments. At first, they completed the healthy condition form, consent, and body composition assessment by a bio-impedance analyzer. Later, they were subjected to perform a graded exercise on cycle, started at 50watts (W), increased 25W per minute, and terminated when pedaling rate below 60 rpm. The EMG signal of right thigh, intervals of heart rate, and gas analysis were simultaneously recorded during the test. They executed a 20m shuttle run test and a 3000m run test on separate day, respectively, for evaluating personal aerobic capacity. The data were analyzed by pair t-test and Pearson product-moment correlation coefficient analysis with SPSS 12.0. The level of significance was set at p < 0.05. The results showed that EMGT and HRVT were highly correlated with VT2 (R=0.771, P < 0.05; R=0.829, P < 0.05). Power at EMGT and HRVT were significantly correlated to the performance of the 20m shuttle run test, with R=0.782, 0.658, respectively. Power at EMGT and HRVT are also significantly correlated with the 3000m performance with R=-0.555, -0.701, respectively. According to the results, the EMGT and HRVT could be convenient and appropriate methods for assessing aerobic-anaerobic transition and are helpful for athletes and coaches to determine the anaerobic threshold for manipulating personal training protocol.
author2 蔡忠昌
author_facet 蔡忠昌
林子揚
author 林子揚
spellingShingle 林子揚
A Correlation Study of Electromyography Threshold, Heart Rate Variability Threshold, Ventilation Threshold and 3000m Performance
author_sort 林子揚
title A Correlation Study of Electromyography Threshold, Heart Rate Variability Threshold, Ventilation Threshold and 3000m Performance
title_short A Correlation Study of Electromyography Threshold, Heart Rate Variability Threshold, Ventilation Threshold and 3000m Performance
title_full A Correlation Study of Electromyography Threshold, Heart Rate Variability Threshold, Ventilation Threshold and 3000m Performance
title_fullStr A Correlation Study of Electromyography Threshold, Heart Rate Variability Threshold, Ventilation Threshold and 3000m Performance
title_full_unstemmed A Correlation Study of Electromyography Threshold, Heart Rate Variability Threshold, Ventilation Threshold and 3000m Performance
title_sort correlation study of electromyography threshold, heart rate variability threshold, ventilation threshold and 3000m performance
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/26026574007956980405
work_keys_str_mv AT línziyáng acorrelationstudyofelectromyographythresholdheartratevariabilitythresholdventilationthresholdand3000mperformance
AT línziyáng jiànzēngshìyùndòngzhōngjīdiànjíxīnlǜbiànyìyùzhíyǔwúyǎngyùzhíjí3000gōngchǐchéngjīxiāngguānxìngzhīyánjiū
AT línziyáng correlationstudyofelectromyographythresholdheartratevariabilitythresholdventilationthresholdand3000mperformance
_version_ 1718124294130630656