Pneumatically-driven Active Check Valve-aided Micropump for Liquid Transportation
碩士 === 義守大學 === 機械與自動化工程學系碩士班 === 98 === Basic microfluidic components, such as microchannels, microvalves, micropumps, micromixers and microreactors with various novel sensors and detection platforms have been successfully applied in the microfluidics and Bio-MEMS fields. Among them, the micropumps a...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
2010
|
Online Access: | http://ndltd.ncl.edu.tw/handle/90826499237244615521 |
id |
ndltd-TW-098ISU05689008 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-098ISU056890082016-04-27T04:12:16Z http://ndltd.ncl.edu.tw/handle/90826499237244615521 Pneumatically-driven Active Check Valve-aided Micropump for Liquid Transportation 無 Gia-thinh Bui 裴家盛 碩士 義守大學 機械與自動化工程學系碩士班 98 Basic microfluidic components, such as microchannels, microvalves, micropumps, micromixers and microreactors with various novel sensors and detection platforms have been successfully applied in the microfluidics and Bio-MEMS fields. Among them, the micropumps are the most important components due to the use of sample delivery and manipulation in the microfluidic devices and systems. In this study, a new micro-pump utilizing active check-valve structures has been successfully demonstrated for sample transportation. The moving structure with an active check-valve is activated pneumatically to deform the PDMS membrane and generate a transporting of the sample streams to the detected region. Meanwhile, a theoretical analysis and a numerical simulation were employed to investigate the deformation mechanism and then confirmed by experimental data. Hence, the numerical calculations were also used to design the optimum actuated membrane. Variations of the generated flow rate with the pneumatic frequencies, actuated air pressures and operated cases are analyzed experimentally. The larger flow rates are obtained for the basic parameters such as driving frequencies and actuated air pressures depended on design features. The optimum parameters of air pressure, driving frequency, and location position of active check valve are experimentally 10 psi, 26 Hz, and 600 μm, respectively. The maximum pumping rate was found to be 532μL/min. Furthermore, the proposed micro-pump could be crucial for the transportation of the microfluidics and could be incorporated with the micro-total-analysis-systems. Jhih-long Lin 林志龍 2010 學位論文 ; thesis 60 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 義守大學 === 機械與自動化工程學系碩士班 === 98 === Basic microfluidic components, such as microchannels, microvalves, micropumps, micromixers and microreactors with various novel sensors and detection platforms have been successfully applied in the microfluidics and Bio-MEMS fields. Among them, the micropumps are the most important components due to the use of sample delivery and manipulation in the microfluidic devices and systems. In this study, a new micro-pump utilizing active check-valve structures has been successfully demonstrated for sample transportation. The moving structure with an active check-valve is activated pneumatically to deform the PDMS membrane and generate a transporting of the sample streams to the detected region. Meanwhile, a theoretical analysis and a numerical simulation were employed to investigate the deformation mechanism and then confirmed by experimental data. Hence, the numerical calculations were also used to design the optimum actuated membrane. Variations of the generated flow rate with the pneumatic frequencies, actuated air pressures and operated cases are analyzed experimentally. The larger flow rates are obtained for the basic parameters such as driving frequencies and actuated air pressures depended on design features. The optimum parameters of air pressure, driving frequency, and location position of active check valve are experimentally 10 psi, 26 Hz, and 600 μm, respectively. The maximum pumping rate was found to be 532μL/min. Furthermore, the proposed micro-pump could be crucial for the transportation of the microfluidics and could be incorporated with the micro-total-analysis-systems.
|
author2 |
Jhih-long Lin |
author_facet |
Jhih-long Lin Gia-thinh Bui 裴家盛 |
author |
Gia-thinh Bui 裴家盛 |
spellingShingle |
Gia-thinh Bui 裴家盛 Pneumatically-driven Active Check Valve-aided Micropump for Liquid Transportation |
author_sort |
Gia-thinh Bui |
title |
Pneumatically-driven Active Check Valve-aided Micropump for Liquid Transportation |
title_short |
Pneumatically-driven Active Check Valve-aided Micropump for Liquid Transportation |
title_full |
Pneumatically-driven Active Check Valve-aided Micropump for Liquid Transportation |
title_fullStr |
Pneumatically-driven Active Check Valve-aided Micropump for Liquid Transportation |
title_full_unstemmed |
Pneumatically-driven Active Check Valve-aided Micropump for Liquid Transportation |
title_sort |
pneumatically-driven active check valve-aided micropump for liquid transportation |
publishDate |
2010 |
url |
http://ndltd.ncl.edu.tw/handle/90826499237244615521 |
work_keys_str_mv |
AT giathinhbui pneumaticallydrivenactivecheckvalveaidedmicropumpforliquidtransportation AT péijiāshèng pneumaticallydrivenactivecheckvalveaidedmicropumpforliquidtransportation AT giathinhbui wú AT péijiāshèng wú |
_version_ |
1718250259647299584 |