High Throughput Screening for Zearalenone by Matrix-Assisted Laser Desorption/Inoization Time-of -Flight Mass Spectrometry

碩士 === 朝陽科技大學 === 應用化學系碩士班 === 98 === Zearalenone (ZEA) is one of the mycotoxins which are the secondary metabolites of fungi. It is found in corn, wheat, barley and oats. In Taiwan, the official analysis method for ZEA is using disposable immunoaffinity column coupling with high performance liquid...

Full description

Bibliographic Details
Main Authors: Shiau-Pei Lin, 林曉珮
Other Authors: ChangNanChen
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/24451532426214919195
id ndltd-TW-098CYUT5500014
record_format oai_dc
spelling ndltd-TW-098CYUT55000142015-10-13T18:35:38Z http://ndltd.ncl.edu.tw/handle/24451532426214919195 High Throughput Screening for Zearalenone by Matrix-Assisted Laser Desorption/Inoization Time-of -Flight Mass Spectrometry 利用MALDI-TOF質譜法進行大量、快速篩檢Zearalenone毒素之偵測技術 Shiau-Pei Lin 林曉珮 碩士 朝陽科技大學 應用化學系碩士班 98 Zearalenone (ZEA) is one of the mycotoxins which are the secondary metabolites of fungi. It is found in corn, wheat, barley and oats. In Taiwan, the official analysis method for ZEA is using disposable immunoaffinity column coupling with high performance liquid chromatography (HPLC) which has the detection limit of 10 ppb. However, the modern preservation of grain has reduced the contamination of ZEA in corps. The cost of the specific column and the time consuming are not good for high throughput analysis. If there is a low cost and high throughput screening methods to filter out most uncontaminated samples, a lot of time consuming and cost would be avoided. Here we report a low cost and high throughput screening method for the analysis of ZEA using matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). This method includes two parts. First, the sample preparation using celite to remove sample matrix is simple and low cost. Second, without general matrix for co-crystal with analyte, aluminum foil is used to obtain low noise analyte spectra in low mass range. The cost of sample preparation for each sample is less than NT$ 10.0 dollars, and analysis time for each sample is only 1 min or less, detection limit can reach to 10 ppb which is comparable with the official method. ChangNanChen 陳政男 2010 學位論文 ; thesis 124 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 朝陽科技大學 === 應用化學系碩士班 === 98 === Zearalenone (ZEA) is one of the mycotoxins which are the secondary metabolites of fungi. It is found in corn, wheat, barley and oats. In Taiwan, the official analysis method for ZEA is using disposable immunoaffinity column coupling with high performance liquid chromatography (HPLC) which has the detection limit of 10 ppb. However, the modern preservation of grain has reduced the contamination of ZEA in corps. The cost of the specific column and the time consuming are not good for high throughput analysis. If there is a low cost and high throughput screening methods to filter out most uncontaminated samples, a lot of time consuming and cost would be avoided. Here we report a low cost and high throughput screening method for the analysis of ZEA using matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). This method includes two parts. First, the sample preparation using celite to remove sample matrix is simple and low cost. Second, without general matrix for co-crystal with analyte, aluminum foil is used to obtain low noise analyte spectra in low mass range. The cost of sample preparation for each sample is less than NT$ 10.0 dollars, and analysis time for each sample is only 1 min or less, detection limit can reach to 10 ppb which is comparable with the official method.
author2 ChangNanChen
author_facet ChangNanChen
Shiau-Pei Lin
林曉珮
author Shiau-Pei Lin
林曉珮
spellingShingle Shiau-Pei Lin
林曉珮
High Throughput Screening for Zearalenone by Matrix-Assisted Laser Desorption/Inoization Time-of -Flight Mass Spectrometry
author_sort Shiau-Pei Lin
title High Throughput Screening for Zearalenone by Matrix-Assisted Laser Desorption/Inoization Time-of -Flight Mass Spectrometry
title_short High Throughput Screening for Zearalenone by Matrix-Assisted Laser Desorption/Inoization Time-of -Flight Mass Spectrometry
title_full High Throughput Screening for Zearalenone by Matrix-Assisted Laser Desorption/Inoization Time-of -Flight Mass Spectrometry
title_fullStr High Throughput Screening for Zearalenone by Matrix-Assisted Laser Desorption/Inoization Time-of -Flight Mass Spectrometry
title_full_unstemmed High Throughput Screening for Zearalenone by Matrix-Assisted Laser Desorption/Inoization Time-of -Flight Mass Spectrometry
title_sort high throughput screening for zearalenone by matrix-assisted laser desorption/inoization time-of -flight mass spectrometry
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/24451532426214919195
work_keys_str_mv AT shiaupeilin highthroughputscreeningforzearalenonebymatrixassistedlaserdesorptioninoizationtimeofflightmassspectrometry
AT línxiǎopèi highthroughputscreeningforzearalenonebymatrixassistedlaserdesorptioninoizationtimeofflightmassspectrometry
AT shiaupeilin lìyòngmalditofzhìpǔfǎjìnxíngdàliàngkuàisùshāijiǎnzearalenonedúsùzhīzhēncèjìshù
AT línxiǎopèi lìyòngmalditofzhìpǔfǎjìnxíngdàliàngkuàisùshāijiǎnzearalenonedúsùzhīzhēncèjìshù
_version_ 1718035347563085824