The blurry medical image evaluated by using objective methods

碩士 === 中臺科技大學 === 放射科學研究所 === 98 === The purpose of this study was to seek an optimal method for measuring the image quality of MRI images after filtering. The study chose 80 slices brain image of MRI. They included T1WI, T2WI, T1 Flair and T2 Flair series. The original images were processed with th...

Full description

Bibliographic Details
Main Authors: Pi-hui Hung, 洪碧慧
Other Authors: Cheng-hsun Lin
Format: Others
Language:zh-TW
Published: 2010
Online Access:http://ndltd.ncl.edu.tw/handle/39705500505475201897
id ndltd-TW-098CTC05605006
record_format oai_dc
spelling ndltd-TW-098CTC056050062015-10-13T18:49:18Z http://ndltd.ncl.edu.tw/handle/39705500505475201897 The blurry medical image evaluated by using objective methods 以客觀方法評估醫學影像模糊 Pi-hui Hung 洪碧慧 碩士 中臺科技大學 放射科學研究所 98 The purpose of this study was to seek an optimal method for measuring the image quality of MRI images after filtering. The study chose 80 slices brain image of MRI. They included T1WI, T2WI, T1 Flair and T2 Flair series. The original images were processed with the filter of the system, and to analyze them with objective method. In this work, the authors applied different level of filtering for brain MRI images. There were six objective methods to evaluate image quality, one was Pixel Based-Metric (PBM) and the other was Window Based-Metric (WBM). The PBM included Mean Square Error (MSE), Signal to Noise Ratio (SNR), Peak Signal to Noise Ratio (PSNR) meanwhile Universal Quality Index (UQI), Mean Structural Similarity (MSSIM), and Moran’s Peak Ratio (MPR) was for WBM. The PBM was very sensitive to image degradation but didn’t correlate well to subjective quality measures. The image spatial information was estimated from a local region by window based-metric, especially in MPR measurement. Apply the filter process by series, the researcher found that the image showed differences of MPR between T1and T2. The MPR was shown to be very sensitive to image quality of MRI filter, MPR was recommend as for measuring the image quality of MRI images after filtering. Cheng-hsun Lin 林政勳 2010 學位論文 ; thesis 85 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中臺科技大學 === 放射科學研究所 === 98 === The purpose of this study was to seek an optimal method for measuring the image quality of MRI images after filtering. The study chose 80 slices brain image of MRI. They included T1WI, T2WI, T1 Flair and T2 Flair series. The original images were processed with the filter of the system, and to analyze them with objective method. In this work, the authors applied different level of filtering for brain MRI images. There were six objective methods to evaluate image quality, one was Pixel Based-Metric (PBM) and the other was Window Based-Metric (WBM). The PBM included Mean Square Error (MSE), Signal to Noise Ratio (SNR), Peak Signal to Noise Ratio (PSNR) meanwhile Universal Quality Index (UQI), Mean Structural Similarity (MSSIM), and Moran’s Peak Ratio (MPR) was for WBM. The PBM was very sensitive to image degradation but didn’t correlate well to subjective quality measures. The image spatial information was estimated from a local region by window based-metric, especially in MPR measurement. Apply the filter process by series, the researcher found that the image showed differences of MPR between T1and T2. The MPR was shown to be very sensitive to image quality of MRI filter, MPR was recommend as for measuring the image quality of MRI images after filtering.
author2 Cheng-hsun Lin
author_facet Cheng-hsun Lin
Pi-hui Hung
洪碧慧
author Pi-hui Hung
洪碧慧
spellingShingle Pi-hui Hung
洪碧慧
The blurry medical image evaluated by using objective methods
author_sort Pi-hui Hung
title The blurry medical image evaluated by using objective methods
title_short The blurry medical image evaluated by using objective methods
title_full The blurry medical image evaluated by using objective methods
title_fullStr The blurry medical image evaluated by using objective methods
title_full_unstemmed The blurry medical image evaluated by using objective methods
title_sort blurry medical image evaluated by using objective methods
publishDate 2010
url http://ndltd.ncl.edu.tw/handle/39705500505475201897
work_keys_str_mv AT pihuihung theblurrymedicalimageevaluatedbyusingobjectivemethods
AT hóngbìhuì theblurrymedicalimageevaluatedbyusingobjectivemethods
AT pihuihung yǐkèguānfāngfǎpínggūyīxuéyǐngxiàngmóhú
AT hóngbìhuì yǐkèguānfāngfǎpínggūyīxuéyǐngxiàngmóhú
AT pihuihung blurrymedicalimageevaluatedbyusingobjectivemethods
AT hóngbìhuì blurrymedicalimageevaluatedbyusingobjectivemethods
_version_ 1718036697239781376