Research on an Electro-pneumatic Vibration Isolation Stage

碩士 === 國立雲林科技大學 === 機械工程系碩士班 === 97 === In this thesis a linear variable differential transformer (LVDT) and a proportional pneumatic valve are used to replace the mechanical leveling valve in a vibration isolation table. Besides alleviating the problem of abrasion in a mechanical leveling valve, t...