Energy-Saving Performance Measurement and Verification Methods for Circulating Water Pumps in Air-Conditioning Systems

碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 97 === Pumps in the current methods of measurement, mainly『CNS665』 test announced by general law, in order to establish water saving performance measurement and verification methods, In this study, the actual cases, respectively, for the fixed-frequency, frequen...

Full description

Bibliographic Details
Main Authors: Huang-Chih Ho, 何皇智
Other Authors: 柯明村
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/4d6p2e
id ndltd-TW-097TIT05703016
record_format oai_dc
spelling ndltd-TW-097TIT057030162019-08-21T03:41:28Z http://ndltd.ncl.edu.tw/handle/4d6p2e Energy-Saving Performance Measurement and Verification Methods for Circulating Water Pumps in Air-Conditioning Systems 應用於空調循環水泵節能績效改善之量測與驗證方法 Huang-Chih Ho 何皇智 碩士 國立臺北科技大學 能源與冷凍空調工程系碩士班 97 Pumps in the current methods of measurement, mainly『CNS665』 test announced by general law, in order to establish water saving performance measurement and verification methods, In this study, the actual cases, respectively, for the fixed-frequency, frequency and the pump impeller to amend the case, for data analysis, evaluation and the establishment of the performance of air conditioning experience model circulating water pump in order to build water pump project to improve the energy efficiency of the verification process with the theoretical model calculation. The purpose of this study is the use of particles were carried out in baseline algorithm model, so that the regression coefficient calculated with the actual consumption of electricity to improve the error can be reduced by the actual results show that the average pump frequency error rate for the 0.79%, water pump impeller to amend the average error rate of 1.67 percent and the average pump frequency rate of 12.93 percent error in the establishment of the three different types of improvements, mainly in order to provide for future energy-saving performance in the water pump to ensure the implementation of the improvement project way of reference. 柯明村 楊安石 2009 學位論文 ; thesis 55 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 97 === Pumps in the current methods of measurement, mainly『CNS665』 test announced by general law, in order to establish water saving performance measurement and verification methods, In this study, the actual cases, respectively, for the fixed-frequency, frequency and the pump impeller to amend the case, for data analysis, evaluation and the establishment of the performance of air conditioning experience model circulating water pump in order to build water pump project to improve the energy efficiency of the verification process with the theoretical model calculation. The purpose of this study is the use of particles were carried out in baseline algorithm model, so that the regression coefficient calculated with the actual consumption of electricity to improve the error can be reduced by the actual results show that the average pump frequency error rate for the 0.79%, water pump impeller to amend the average error rate of 1.67 percent and the average pump frequency rate of 12.93 percent error in the establishment of the three different types of improvements, mainly in order to provide for future energy-saving performance in the water pump to ensure the implementation of the improvement project way of reference.
author2 柯明村
author_facet 柯明村
Huang-Chih Ho
何皇智
author Huang-Chih Ho
何皇智
spellingShingle Huang-Chih Ho
何皇智
Energy-Saving Performance Measurement and Verification Methods for Circulating Water Pumps in Air-Conditioning Systems
author_sort Huang-Chih Ho
title Energy-Saving Performance Measurement and Verification Methods for Circulating Water Pumps in Air-Conditioning Systems
title_short Energy-Saving Performance Measurement and Verification Methods for Circulating Water Pumps in Air-Conditioning Systems
title_full Energy-Saving Performance Measurement and Verification Methods for Circulating Water Pumps in Air-Conditioning Systems
title_fullStr Energy-Saving Performance Measurement and Verification Methods for Circulating Water Pumps in Air-Conditioning Systems
title_full_unstemmed Energy-Saving Performance Measurement and Verification Methods for Circulating Water Pumps in Air-Conditioning Systems
title_sort energy-saving performance measurement and verification methods for circulating water pumps in air-conditioning systems
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/4d6p2e
work_keys_str_mv AT huangchihho energysavingperformancemeasurementandverificationmethodsforcirculatingwaterpumpsinairconditioningsystems
AT héhuángzhì energysavingperformancemeasurementandverificationmethodsforcirculatingwaterpumpsinairconditioningsystems
AT huangchihho yīngyòngyúkōngdiàoxúnhuánshuǐbèngjiénéngjīxiàogǎishànzhīliàngcèyǔyànzhèngfāngfǎ
AT héhuángzhì yīngyòngyúkōngdiàoxúnhuánshuǐbèngjiénéngjīxiàogǎishànzhīliàngcèyǔyànzhèngfāngfǎ
_version_ 1719235606275424256