The Research of Cooling-load Simulation to Innovative Multi-function and Uniform External Shading Device for Building Interiors

碩士 === 國立臺北科技大學 === 建築與都市設計研究所 === 97 === This study is the integrated design of innovative multi-function external shading device. In order to make everyone remove the stereotype of external shading device, it will have both artistic and practical features. The content of the research is the impact...

Full description

Bibliographic Details
Main Authors: Sung-Feng Wang, 王淞鋒
Other Authors: 周鼎金
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/uk6nrh
id ndltd-TW-097TIT05224023
record_format oai_dc
spelling ndltd-TW-097TIT052240232019-08-16T03:39:25Z http://ndltd.ncl.edu.tw/handle/uk6nrh The Research of Cooling-load Simulation to Innovative Multi-function and Uniform External Shading Device for Building Interiors 創新多功能與制式外遮陽對室內空調負荷模擬之研究 Sung-Feng Wang 王淞鋒 碩士 國立臺北科技大學 建築與都市設計研究所 97 This study is the integrated design of innovative multi-function external shading device. In order to make everyone remove the stereotype of external shading device, it will have both artistic and practical features. The content of the research is the impact of indoor temperature by using the software simulation of air-conditioning load and field measurement of uniform external shading device, and that will be reviewed and improved for the issue of uniform external shading device and the integrated design of innovative multi-function. The results of this study are as follows: 1. It is performed to improve the design of uniform external shading device by using the software simulation. Through the data of air-conditioning load, it will be known that the best choice can make the air-conditioning load reduced and make material costs minimized when the angle of uniform external shading device is 0 degree and the distance between the level of penetration of louvers is 4 centimeters. 2. It is operated by the software of the innovative multi-function of external shading device to simulate seasonal changes. According to seasonally different condition, the suggestion that the shielding angle is dividedly 8.5 degrees in fall, 18 degrees in spring, 26 degrees in summer and 90 degrees in winter. This strategy can effectively reduce air-conditioning load. 3. The data of air-conditioning load shows that the percentage of the total energy-saving type dividedly reach 5.3% for innovative activities external shading device, 5.3% for the level spacing of 4 centimeters of improved uniform one, and 5.3% for the original uniform one by the Ecotect software simulation. Therefore, comparing cooling-load of the three types external shading device, are the same. 周鼎金 2009 學位論文 ; thesis 103 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 建築與都市設計研究所 === 97 === This study is the integrated design of innovative multi-function external shading device. In order to make everyone remove the stereotype of external shading device, it will have both artistic and practical features. The content of the research is the impact of indoor temperature by using the software simulation of air-conditioning load and field measurement of uniform external shading device, and that will be reviewed and improved for the issue of uniform external shading device and the integrated design of innovative multi-function. The results of this study are as follows: 1. It is performed to improve the design of uniform external shading device by using the software simulation. Through the data of air-conditioning load, it will be known that the best choice can make the air-conditioning load reduced and make material costs minimized when the angle of uniform external shading device is 0 degree and the distance between the level of penetration of louvers is 4 centimeters. 2. It is operated by the software of the innovative multi-function of external shading device to simulate seasonal changes. According to seasonally different condition, the suggestion that the shielding angle is dividedly 8.5 degrees in fall, 18 degrees in spring, 26 degrees in summer and 90 degrees in winter. This strategy can effectively reduce air-conditioning load. 3. The data of air-conditioning load shows that the percentage of the total energy-saving type dividedly reach 5.3% for innovative activities external shading device, 5.3% for the level spacing of 4 centimeters of improved uniform one, and 5.3% for the original uniform one by the Ecotect software simulation. Therefore, comparing cooling-load of the three types external shading device, are the same.
author2 周鼎金
author_facet 周鼎金
Sung-Feng Wang
王淞鋒
author Sung-Feng Wang
王淞鋒
spellingShingle Sung-Feng Wang
王淞鋒
The Research of Cooling-load Simulation to Innovative Multi-function and Uniform External Shading Device for Building Interiors
author_sort Sung-Feng Wang
title The Research of Cooling-load Simulation to Innovative Multi-function and Uniform External Shading Device for Building Interiors
title_short The Research of Cooling-load Simulation to Innovative Multi-function and Uniform External Shading Device for Building Interiors
title_full The Research of Cooling-load Simulation to Innovative Multi-function and Uniform External Shading Device for Building Interiors
title_fullStr The Research of Cooling-load Simulation to Innovative Multi-function and Uniform External Shading Device for Building Interiors
title_full_unstemmed The Research of Cooling-load Simulation to Innovative Multi-function and Uniform External Shading Device for Building Interiors
title_sort research of cooling-load simulation to innovative multi-function and uniform external shading device for building interiors
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/uk6nrh
work_keys_str_mv AT sungfengwang theresearchofcoolingloadsimulationtoinnovativemultifunctionanduniformexternalshadingdeviceforbuildinginteriors
AT wángsōngfēng theresearchofcoolingloadsimulationtoinnovativemultifunctionanduniformexternalshadingdeviceforbuildinginteriors
AT sungfengwang chuàngxīnduōgōngnéngyǔzhìshìwàizhēyángduìshìnèikōngdiàofùhémónǐzhīyánjiū
AT wángsōngfēng chuàngxīnduōgōngnéngyǔzhìshìwàizhēyángduìshìnèikōngdiàofùhémónǐzhīyánjiū
AT sungfengwang researchofcoolingloadsimulationtoinnovativemultifunctionanduniformexternalshadingdeviceforbuildinginteriors
AT wángsōngfēng researchofcoolingloadsimulationtoinnovativemultifunctionanduniformexternalshadingdeviceforbuildinginteriors
_version_ 1719234558300258304