Natural Convection Heat Transfer Characteristics and cooling Performance Enhancement for a Module with Block Heat Sources in a Three Dimensional Cabinet
碩士 === 國立虎尾科技大學 === 航空與電子科技研究所 === 97 === This study aims to investigate natural convection heat transfer characteristics and cooling performance enhancement for a module with block heat sources in a three dimensional cabinet. The major objective of this study has two aspects. First, efforts are per...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2009
|
Online Access: | http://ndltd.ncl.edu.tw/handle/sm6btd |
id |
ndltd-TW-097NYPI5294004 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-097NYPI52940042019-09-22T03:40:56Z http://ndltd.ncl.edu.tw/handle/sm6btd Natural Convection Heat Transfer Characteristics and cooling Performance Enhancement for a Module with Block Heat Sources in a Three Dimensional Cabinet 具凸塊熱源之模組於三維機匣中自然對流熱傳特性及散熱性能增進之研究 Ci-Ming Huang 黃啟銘 碩士 國立虎尾科技大學 航空與電子科技研究所 97 This study aims to investigate natural convection heat transfer characteristics and cooling performance enhancement for a module with block heat sources in a three dimensional cabinet. The major objective of this study has two aspects. First, efforts are performed to examine the influences of thermal interaction between the fluids inside and outside the cabinet on the flow structure, temperature distribution and Nu number. Second, air vents are proposed to construct in the three dimensional cabinet wall, attentions are paid to conduct the enhancement of cooling performance of the block heat sources. The numerical computation domain covers the cabinet and surrounding area, the temperature and heat flux on the cabinet surface are not previously known and have to be found in the solution processes, In addition, in order to verify the numerical simulation, this study has set up an experimental system. The difference in surface temperature of block between the numerical and experimental data is within 11.1%~22.5%. The maximum difference in hot spot temperatures of the blocks for the situations with and without consideration of thermal interaction can be up to 24.5 % as Pr = 0.7, 104≦Ra≦106, 100≦Kbf = Kpf = Kwf = 1000 and Kff = 8000. When air vents are constructed in the cabinet wall, the hot spot temperature can be reduced by 30.5 %. In addition, when fin is constructed on the back side of the board for the ventilated cabinet, the hot spot temperature can be reduced by 52 %. Yeong-Ley Tsay 蔡永利 2009 學位論文 ; thesis 57 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立虎尾科技大學 === 航空與電子科技研究所 === 97 === This study aims to investigate natural convection heat transfer characteristics and cooling performance enhancement for a module with block heat sources in a three dimensional cabinet. The major objective of this study has two aspects. First, efforts are performed to examine the influences of thermal interaction between the fluids inside and outside the cabinet on the flow structure, temperature distribution and Nu number. Second, air vents are proposed to construct in the three dimensional cabinet wall, attentions are paid to conduct the enhancement of cooling performance of the block heat sources.
The numerical computation domain covers the cabinet and surrounding area, the temperature and heat flux on the cabinet surface are not previously known and have to be found in the solution processes, In addition, in order to verify the numerical simulation, this study has set up an experimental system. The difference in surface temperature of block between the numerical and experimental data is within 11.1%~22.5%.
The maximum difference in hot spot temperatures of the blocks for the situations with and without consideration of thermal interaction can be up to 24.5 % as Pr = 0.7, 104≦Ra≦106, 100≦Kbf = Kpf = Kwf = 1000 and Kff = 8000. When air vents are constructed in the cabinet wall, the hot spot temperature can be reduced by 30.5 %. In addition, when fin is constructed on the back side of the board for the ventilated cabinet, the hot spot temperature can be reduced by 52 %.
|
author2 |
Yeong-Ley Tsay |
author_facet |
Yeong-Ley Tsay Ci-Ming Huang 黃啟銘 |
author |
Ci-Ming Huang 黃啟銘 |
spellingShingle |
Ci-Ming Huang 黃啟銘 Natural Convection Heat Transfer Characteristics and cooling Performance Enhancement for a Module with Block Heat Sources in a Three Dimensional Cabinet |
author_sort |
Ci-Ming Huang |
title |
Natural Convection Heat Transfer Characteristics and cooling Performance Enhancement for a Module with Block Heat Sources in a Three Dimensional Cabinet |
title_short |
Natural Convection Heat Transfer Characteristics and cooling Performance Enhancement for a Module with Block Heat Sources in a Three Dimensional Cabinet |
title_full |
Natural Convection Heat Transfer Characteristics and cooling Performance Enhancement for a Module with Block Heat Sources in a Three Dimensional Cabinet |
title_fullStr |
Natural Convection Heat Transfer Characteristics and cooling Performance Enhancement for a Module with Block Heat Sources in a Three Dimensional Cabinet |
title_full_unstemmed |
Natural Convection Heat Transfer Characteristics and cooling Performance Enhancement for a Module with Block Heat Sources in a Three Dimensional Cabinet |
title_sort |
natural convection heat transfer characteristics and cooling performance enhancement for a module with block heat sources in a three dimensional cabinet |
publishDate |
2009 |
url |
http://ndltd.ncl.edu.tw/handle/sm6btd |
work_keys_str_mv |
AT ciminghuang naturalconvectionheattransfercharacteristicsandcoolingperformanceenhancementforamodulewithblockheatsourcesinathreedimensionalcabinet AT huángqǐmíng naturalconvectionheattransfercharacteristicsandcoolingperformanceenhancementforamodulewithblockheatsourcesinathreedimensionalcabinet AT ciminghuang jùtūkuàirèyuánzhīmózǔyúsānwéijīxiázhōngzìránduìliúrèchuántèxìngjísànrèxìngnéngzēngjìnzhīyánjiū AT huángqǐmíng jùtūkuàirèyuánzhīmózǔyúsānwéijīxiázhōngzìránduìliúrèchuántèxìngjísànrèxìngnéngzēngjìnzhīyánjiū |
_version_ |
1719254263420420096 |