Investigation on Performance of Self-Made Generic Multi-Purpose Heat Pump

碩士 === 國立臺灣大學 === 生物產業機電工程學研究所 === 97 === The focuses of this study were to develop a generic multi-purpose heat pump capable of providing cold water, cold air, hot water and warm air at the same time, as well as to investigate on the impacts to the coefficient of performance of the system and the c...

Full description

Bibliographic Details
Main Authors: Po-Chiun Tseng, 曾博群
Other Authors: Wei Fang
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/99140175807044726058
id ndltd-TW-097NTU05415017
record_format oai_dc
spelling ndltd-TW-097NTU054150172016-05-02T04:11:08Z http://ndltd.ncl.edu.tw/handle/99140175807044726058 Investigation on Performance of Self-Made Generic Multi-Purpose Heat Pump 自製泛用型多功能熱泵於不同操作條件下性能係數之探討 Po-Chiun Tseng 曾博群 碩士 國立臺灣大學 生物產業機電工程學研究所 97 The focuses of this study were to develop a generic multi-purpose heat pump capable of providing cold water, cold air, hot water and warm air at the same time, as well as to investigate on the impacts to the coefficient of performance of the system and the compressor due to various operating conditions in either high pressure and/or low pressure side of the refrigeration cycle, including on/off of the second stage heat exchangers and steady or transient state of water flow through water-air heat exchangers. This generic system consists of compressor, pressure accumulator, plate-type heat exchangers, air-water heat exchangers, dual pipe heat exchanger, capillary tube, thermal-controlled expansion valve and gas-liquid separator. The components selected for this generic design are as follows: capacity of the compressor is 1.5 USRT, power of fans of the air-water heat exchangers are 60 W, amount of water in the hot and cold water tanks are 40 L and 150 L, respectively, and the flow rate of the water re-circulating in both plate-type heat exchangers is 1160 L/hr. Subject to the components previously selected, other corresponding components were under investigation in order to reach highest COP, the selected components are: pressure accumulator at the capacity of 0.77 L, plate-type heat exchanger with the heat exchange area of 0.432 m2 at the cold (low pressure) side, and 0.421 m2 at the hot (high pressure) side, capillary tube at the length of 45 cm and amount of refrigerant R22 charged in to the cycle at the weight of 1.5 kg. With such combinations, the high pressure side of the COP of the system and compressor is 2.87 and 3.38, respectively, the low pressure side of the COP of the system and compressor is 2.86 and 3.29, respectively and the total COP of the system and compressor is 5.21and 6.53, respectively when the water temperature is to be raised from 20 C to 50 degree C. Wei Fang 方煒 2009 學位論文 ; thesis 89 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 生物產業機電工程學研究所 === 97 === The focuses of this study were to develop a generic multi-purpose heat pump capable of providing cold water, cold air, hot water and warm air at the same time, as well as to investigate on the impacts to the coefficient of performance of the system and the compressor due to various operating conditions in either high pressure and/or low pressure side of the refrigeration cycle, including on/off of the second stage heat exchangers and steady or transient state of water flow through water-air heat exchangers. This generic system consists of compressor, pressure accumulator, plate-type heat exchangers, air-water heat exchangers, dual pipe heat exchanger, capillary tube, thermal-controlled expansion valve and gas-liquid separator. The components selected for this generic design are as follows: capacity of the compressor is 1.5 USRT, power of fans of the air-water heat exchangers are 60 W, amount of water in the hot and cold water tanks are 40 L and 150 L, respectively, and the flow rate of the water re-circulating in both plate-type heat exchangers is 1160 L/hr. Subject to the components previously selected, other corresponding components were under investigation in order to reach highest COP, the selected components are: pressure accumulator at the capacity of 0.77 L, plate-type heat exchanger with the heat exchange area of 0.432 m2 at the cold (low pressure) side, and 0.421 m2 at the hot (high pressure) side, capillary tube at the length of 45 cm and amount of refrigerant R22 charged in to the cycle at the weight of 1.5 kg. With such combinations, the high pressure side of the COP of the system and compressor is 2.87 and 3.38, respectively, the low pressure side of the COP of the system and compressor is 2.86 and 3.29, respectively and the total COP of the system and compressor is 5.21and 6.53, respectively when the water temperature is to be raised from 20 C to 50 degree C.
author2 Wei Fang
author_facet Wei Fang
Po-Chiun Tseng
曾博群
author Po-Chiun Tseng
曾博群
spellingShingle Po-Chiun Tseng
曾博群
Investigation on Performance of Self-Made Generic Multi-Purpose Heat Pump
author_sort Po-Chiun Tseng
title Investigation on Performance of Self-Made Generic Multi-Purpose Heat Pump
title_short Investigation on Performance of Self-Made Generic Multi-Purpose Heat Pump
title_full Investigation on Performance of Self-Made Generic Multi-Purpose Heat Pump
title_fullStr Investigation on Performance of Self-Made Generic Multi-Purpose Heat Pump
title_full_unstemmed Investigation on Performance of Self-Made Generic Multi-Purpose Heat Pump
title_sort investigation on performance of self-made generic multi-purpose heat pump
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/99140175807044726058
work_keys_str_mv AT pochiuntseng investigationonperformanceofselfmadegenericmultipurposeheatpump
AT céngbóqún investigationonperformanceofselfmadegenericmultipurposeheatpump
AT pochiuntseng zìzhìfànyòngxíngduōgōngnéngrèbèngyúbùtóngcāozuòtiáojiànxiàxìngnéngxìshùzhītàntǎo
AT céngbóqún zìzhìfànyòngxíngduōgōngnéngrèbèngyúbùtóngcāozuòtiáojiànxiàxìngnéngxìshùzhītàntǎo
_version_ 1718253221576704000