Study on Sugar Content Evaluation of Fruits Using Spectral Standardization

碩士 === 國立臺灣大學 === 生物產業機電工程學研究所 === 97 === Near-infrared (NIR) has been widely used in many fields; however, there are still some constraints in application due to the constructional differences among spectrometers. Even if the measurements conducted on the same sample, the spectral responses of inst...

Full description

Bibliographic Details
Main Authors: Wei-Tin Tu, 杜威霆
Other Authors: 陳世銘
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/46717153520039774865
id ndltd-TW-097NTU05415008
record_format oai_dc
spelling ndltd-TW-097NTU054150082016-05-04T04:31:48Z http://ndltd.ncl.edu.tw/handle/46717153520039774865 Study on Sugar Content Evaluation of Fruits Using Spectral Standardization 光譜標準化模式應用於水果糖度檢測之研究 Wei-Tin Tu 杜威霆 碩士 國立臺灣大學 生物產業機電工程學研究所 97 Near-infrared (NIR) has been widely used in many fields; however, there are still some constraints in application due to the constructional differences among spectrometers. Even if the measurements conducted on the same sample, the spectral responses of instruments are different. Therefore, the databases and calibration models built on Master instrument can’t be used for the spectra measured by Slave instrument. In order to solve this problem, the method of Spectral Standardization has been developed. In this research, Spectral Standardization Models were practically applied to the Sugar Content Inspection for Fruits. In this study, Standard Normal Variate (SNV)、Multiplicative Scatter Correction (MSC) and 1st Derivatives Spectral Pretreatment method were combined with the Spectral Mapping methods, such as Piecewise Direct Standardization, (PDS) and Support Vector Standardization (SVS) , in order to find the best Standardization strategy among different instruments. The Standardization ability will be evaluated by the Spectral prediction ability after standardization. The best result for same type spectrometer but different associated apparatus was using PDS with 1st Derivatives. After Standardization, the SEP of slave instrument could be reduced from 3.01 °Brix to 1.27 °Brix, the RSEP also reduced from 21.11 % to 9.07 %. The best result for same type detectors but different optical design was using 1st Derivatives and PDS together, the SEP and RSEP of slave instrument were 15.95 °Brix and 112.94 % before Spectral Standardization; the SEP and RSEP were 0.95 °Brix and 6.73 % after Spectral Standardization, while the SEP and RSEP of master instrument were 0.67 °Brix and 4.91%. The Slave spectra after Standardization almost have the same prediction ability of sugar content as Master spectra, and can be directly applied to the databases built by master instrument. 陳世銘 2009 學位論文 ; thesis 94 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 生物產業機電工程學研究所 === 97 === Near-infrared (NIR) has been widely used in many fields; however, there are still some constraints in application due to the constructional differences among spectrometers. Even if the measurements conducted on the same sample, the spectral responses of instruments are different. Therefore, the databases and calibration models built on Master instrument can’t be used for the spectra measured by Slave instrument. In order to solve this problem, the method of Spectral Standardization has been developed. In this research, Spectral Standardization Models were practically applied to the Sugar Content Inspection for Fruits. In this study, Standard Normal Variate (SNV)、Multiplicative Scatter Correction (MSC) and 1st Derivatives Spectral Pretreatment method were combined with the Spectral Mapping methods, such as Piecewise Direct Standardization, (PDS) and Support Vector Standardization (SVS) , in order to find the best Standardization strategy among different instruments. The Standardization ability will be evaluated by the Spectral prediction ability after standardization. The best result for same type spectrometer but different associated apparatus was using PDS with 1st Derivatives. After Standardization, the SEP of slave instrument could be reduced from 3.01 °Brix to 1.27 °Brix, the RSEP also reduced from 21.11 % to 9.07 %. The best result for same type detectors but different optical design was using 1st Derivatives and PDS together, the SEP and RSEP of slave instrument were 15.95 °Brix and 112.94 % before Spectral Standardization; the SEP and RSEP were 0.95 °Brix and 6.73 % after Spectral Standardization, while the SEP and RSEP of master instrument were 0.67 °Brix and 4.91%. The Slave spectra after Standardization almost have the same prediction ability of sugar content as Master spectra, and can be directly applied to the databases built by master instrument.
author2 陳世銘
author_facet 陳世銘
Wei-Tin Tu
杜威霆
author Wei-Tin Tu
杜威霆
spellingShingle Wei-Tin Tu
杜威霆
Study on Sugar Content Evaluation of Fruits Using Spectral Standardization
author_sort Wei-Tin Tu
title Study on Sugar Content Evaluation of Fruits Using Spectral Standardization
title_short Study on Sugar Content Evaluation of Fruits Using Spectral Standardization
title_full Study on Sugar Content Evaluation of Fruits Using Spectral Standardization
title_fullStr Study on Sugar Content Evaluation of Fruits Using Spectral Standardization
title_full_unstemmed Study on Sugar Content Evaluation of Fruits Using Spectral Standardization
title_sort study on sugar content evaluation of fruits using spectral standardization
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/46717153520039774865
work_keys_str_mv AT weitintu studyonsugarcontentevaluationoffruitsusingspectralstandardization
AT dùwēitíng studyonsugarcontentevaluationoffruitsusingspectralstandardization
AT weitintu guāngpǔbiāozhǔnhuàmóshìyīngyòngyúshuǐguǒtángdùjiǎncèzhīyánjiū
AT dùwēitíng guāngpǔbiāozhǔnhuàmóshìyīngyòngyúshuǐguǒtángdùjiǎncèzhīyánjiū
_version_ 1718259948129878016