Evaluation of Shoulder Functionality Based on Accelerometer and Bending Sensor

碩士 === 國立臺灣大學 === 資訊工程學研究所 === 97 === Persistent rehabilitation can help post-operation patients maintain functionality of shoulder motion. It prevents body from more severe symptoms such as lymphedema and keeps well capability of doing activities of daily life. However, lots of patients always igno...

Full description

Bibliographic Details
Main Authors: Hao-Yuan Chen, 陳皓遠
Other Authors: Hao-Hua Chu
Format: Others
Language:en_US
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/37339095217563308979
id ndltd-TW-097NTU05392067
record_format oai_dc
spelling ndltd-TW-097NTU053920672016-05-04T04:31:47Z http://ndltd.ncl.edu.tw/handle/37339095217563308979 Evaluation of Shoulder Functionality Based on Accelerometer and Bending Sensor 應用加速度器與曲率檢知器於評估肩關節功能之復健 Hao-Yuan Chen 陳皓遠 碩士 國立臺灣大學 資訊工程學研究所 97 Persistent rehabilitation can help post-operation patients maintain functionality of shoulder motion. It prevents body from more severe symptoms such as lymphedema and keeps well capability of doing activities of daily life. However, lots of patients always ignore the importance of persistent rehabilitation due to the deficiency of self-awareness about body status. It makes patients do not spontaneously continue rehabilitation for at least one year. Therefore, it is necessary to provide a mechanism that makes patients gain much incentive to motivate them to do rehabilitation more frequently. Based on the signals from accelerometer and bending sensor, this thesis adopts the supervised learning technique to implement the shoulder functionality evaluation system with linear regression model. The system identifies the most stable shoulder range of motion according to the six shoulder evaluation exercises performed by patients. It also shows the assessment for capability of activities of daily life in order to instantly boost self-awareness about shoulder health status. Not only the feasibility study shows that the mean square error in prediction angle of shoulder range of motion is below 12 degree, but also the system obtains the positive affirmation from real-world patients and physical therapist after they try out the system. Hao-Hua Chu 朱浩華 2009 學位論文 ; thesis 52 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 資訊工程學研究所 === 97 === Persistent rehabilitation can help post-operation patients maintain functionality of shoulder motion. It prevents body from more severe symptoms such as lymphedema and keeps well capability of doing activities of daily life. However, lots of patients always ignore the importance of persistent rehabilitation due to the deficiency of self-awareness about body status. It makes patients do not spontaneously continue rehabilitation for at least one year. Therefore, it is necessary to provide a mechanism that makes patients gain much incentive to motivate them to do rehabilitation more frequently. Based on the signals from accelerometer and bending sensor, this thesis adopts the supervised learning technique to implement the shoulder functionality evaluation system with linear regression model. The system identifies the most stable shoulder range of motion according to the six shoulder evaluation exercises performed by patients. It also shows the assessment for capability of activities of daily life in order to instantly boost self-awareness about shoulder health status. Not only the feasibility study shows that the mean square error in prediction angle of shoulder range of motion is below 12 degree, but also the system obtains the positive affirmation from real-world patients and physical therapist after they try out the system.
author2 Hao-Hua Chu
author_facet Hao-Hua Chu
Hao-Yuan Chen
陳皓遠
author Hao-Yuan Chen
陳皓遠
spellingShingle Hao-Yuan Chen
陳皓遠
Evaluation of Shoulder Functionality Based on Accelerometer and Bending Sensor
author_sort Hao-Yuan Chen
title Evaluation of Shoulder Functionality Based on Accelerometer and Bending Sensor
title_short Evaluation of Shoulder Functionality Based on Accelerometer and Bending Sensor
title_full Evaluation of Shoulder Functionality Based on Accelerometer and Bending Sensor
title_fullStr Evaluation of Shoulder Functionality Based on Accelerometer and Bending Sensor
title_full_unstemmed Evaluation of Shoulder Functionality Based on Accelerometer and Bending Sensor
title_sort evaluation of shoulder functionality based on accelerometer and bending sensor
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/37339095217563308979
work_keys_str_mv AT haoyuanchen evaluationofshoulderfunctionalitybasedonaccelerometerandbendingsensor
AT chénhàoyuǎn evaluationofshoulderfunctionalitybasedonaccelerometerandbendingsensor
AT haoyuanchen yīngyòngjiāsùdùqìyǔqūlǜjiǎnzhīqìyúpínggūjiānguānjiégōngnéngzhīfùjiàn
AT chénhàoyuǎn yīngyòngjiāsùdùqìyǔqūlǜjiǎnzhīqìyúpínggūjiānguānjiégōngnéngzhīfùjiàn
_version_ 1718259909988974592