Development of Chip-Based Open Channel Solid Phase Extraction Coupled to ICP-MS for On-Line Determination of Trace Elements in Microdialysates

碩士 === 國立清華大學 === 生醫工程與環境科學系 === 97 === Abstract Nowadays, inductively coupled plasma mass spectrometry (ICP-MS) has become one of the most powerful trace elemental analytical techniques with high sensitivity as well as wide linear dynamic range and simultaneous multielement detection capability...

Full description

Bibliographic Details
Main Authors: Chen, Wei-Yu, 陳威宇
Other Authors: 孫毓璋
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/95673665109412867579
id ndltd-TW-097NTHU5810047
record_format oai_dc
spelling ndltd-TW-097NTHU58100472015-11-13T04:08:48Z http://ndltd.ncl.edu.tw/handle/95673665109412867579 Development of Chip-Based Open Channel Solid Phase Extraction Coupled to ICP-MS for On-Line Determination of Trace Elements in Microdialysates 建立開管式固相萃取晶片搭配感應耦合電漿質譜儀之連線分析系統進行高鹽基質微透析樣品中微量元素之分析研究 Chen, Wei-Yu 陳威宇 碩士 國立清華大學 生醫工程與環境科學系 97 Abstract Nowadays, inductively coupled plasma mass spectrometry (ICP-MS) has become one of the most powerful trace elemental analytical techniques with high sensitivity as well as wide linear dynamic range and simultaneous multielement detection capability. However, the insufficient tolerance to the dissolved salts and polyatomic interferences always makes it difficult to directly analyze the high-salt content samples. Consequently, incorporating an efficient on-line pretreatment technique with ICP-MS is considered as an indispensable alternative to preconcentrate desired analytes and to minimize the adverse effects resulted from the concomitant matrices. To date, among the available on-line sample pretreatment methods, solid phase extraction (SPE) is particularly useful as a result of its simplicity and efficiency. For purpose of simplifying the analytical procedure and minimizing the volume of chemicals, in this study, a functionalized PMMA fluidic-chip as a solid phase extraction adsorbent was developed to couple with ICP-MS measurement. Recently, Lab-on-valve mesofluidic analytical system (LOV-MFAS) is a potential tool for the analysis of the real-world micro-samples. Based on literatures, the miniaturized SPE devices indeed provide the rapid response time and analytical capability because of its high surface-to-volume ratio and the short diffusion distance. Accordingly, we attempt to exploit a proper and effective SPE material namely functionalized poly(methyl methacrylate) (f-PMMA) for the extraction of trace metal ions, and to develop a mesofluidic SPE chip to eliminate the possible salt-interference resulting from sample matrices prior to ICP-MS measurement. In this study, a simple CO2-laser engraving technique was employed to machine PMMA substrates instead of lithographic techniques and to attain low per-unit manufacturing cost and rapid prototyping. According to our experiment, a hyphenated system of on-line Chip-Based Open-Channel SPE coupled to ICP-MS was successfully constructed for the determination of trace elements in samples of limited volume (5~10 μL). With optimized procedure, the analytical performance of proposed hyphenated system was examined for determining the concentrations of trace elements in standard reference materials (SRM 2670 and 1643e). Presently, we have connected microdialysis (MD) sampling and Chip-Based Open-Channel SPE-ICP-MS together to determine trace elements in the microdialysate samples. For purpose of establishing a physiopathological-related animal model of trace elements, the practicability of this hyphenated system was evaluated in vitro by monitoring the step change in the concentrations of analyte ions in an external microdialysis medium. 孫毓璋 2009 學位論文 ; thesis 101 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立清華大學 === 生醫工程與環境科學系 === 97 === Abstract Nowadays, inductively coupled plasma mass spectrometry (ICP-MS) has become one of the most powerful trace elemental analytical techniques with high sensitivity as well as wide linear dynamic range and simultaneous multielement detection capability. However, the insufficient tolerance to the dissolved salts and polyatomic interferences always makes it difficult to directly analyze the high-salt content samples. Consequently, incorporating an efficient on-line pretreatment technique with ICP-MS is considered as an indispensable alternative to preconcentrate desired analytes and to minimize the adverse effects resulted from the concomitant matrices. To date, among the available on-line sample pretreatment methods, solid phase extraction (SPE) is particularly useful as a result of its simplicity and efficiency. For purpose of simplifying the analytical procedure and minimizing the volume of chemicals, in this study, a functionalized PMMA fluidic-chip as a solid phase extraction adsorbent was developed to couple with ICP-MS measurement. Recently, Lab-on-valve mesofluidic analytical system (LOV-MFAS) is a potential tool for the analysis of the real-world micro-samples. Based on literatures, the miniaturized SPE devices indeed provide the rapid response time and analytical capability because of its high surface-to-volume ratio and the short diffusion distance. Accordingly, we attempt to exploit a proper and effective SPE material namely functionalized poly(methyl methacrylate) (f-PMMA) for the extraction of trace metal ions, and to develop a mesofluidic SPE chip to eliminate the possible salt-interference resulting from sample matrices prior to ICP-MS measurement. In this study, a simple CO2-laser engraving technique was employed to machine PMMA substrates instead of lithographic techniques and to attain low per-unit manufacturing cost and rapid prototyping. According to our experiment, a hyphenated system of on-line Chip-Based Open-Channel SPE coupled to ICP-MS was successfully constructed for the determination of trace elements in samples of limited volume (5~10 μL). With optimized procedure, the analytical performance of proposed hyphenated system was examined for determining the concentrations of trace elements in standard reference materials (SRM 2670 and 1643e). Presently, we have connected microdialysis (MD) sampling and Chip-Based Open-Channel SPE-ICP-MS together to determine trace elements in the microdialysate samples. For purpose of establishing a physiopathological-related animal model of trace elements, the practicability of this hyphenated system was evaluated in vitro by monitoring the step change in the concentrations of analyte ions in an external microdialysis medium.
author2 孫毓璋
author_facet 孫毓璋
Chen, Wei-Yu
陳威宇
author Chen, Wei-Yu
陳威宇
spellingShingle Chen, Wei-Yu
陳威宇
Development of Chip-Based Open Channel Solid Phase Extraction Coupled to ICP-MS for On-Line Determination of Trace Elements in Microdialysates
author_sort Chen, Wei-Yu
title Development of Chip-Based Open Channel Solid Phase Extraction Coupled to ICP-MS for On-Line Determination of Trace Elements in Microdialysates
title_short Development of Chip-Based Open Channel Solid Phase Extraction Coupled to ICP-MS for On-Line Determination of Trace Elements in Microdialysates
title_full Development of Chip-Based Open Channel Solid Phase Extraction Coupled to ICP-MS for On-Line Determination of Trace Elements in Microdialysates
title_fullStr Development of Chip-Based Open Channel Solid Phase Extraction Coupled to ICP-MS for On-Line Determination of Trace Elements in Microdialysates
title_full_unstemmed Development of Chip-Based Open Channel Solid Phase Extraction Coupled to ICP-MS for On-Line Determination of Trace Elements in Microdialysates
title_sort development of chip-based open channel solid phase extraction coupled to icp-ms for on-line determination of trace elements in microdialysates
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/95673665109412867579
work_keys_str_mv AT chenweiyu developmentofchipbasedopenchannelsolidphaseextractioncoupledtoicpmsforonlinedeterminationoftraceelementsinmicrodialysates
AT chénwēiyǔ developmentofchipbasedopenchannelsolidphaseextractioncoupledtoicpmsforonlinedeterminationoftraceelementsinmicrodialysates
AT chenweiyu jiànlìkāiguǎnshìgùxiāngcuìqǔjīngpiàndāpèigǎnyīngǒuhédiànjiāngzhìpǔyízhīliánxiànfēnxīxìtǒngjìnxínggāoyánjīzhìwēitòuxīyàngpǐnzhōngwēiliàngyuánsùzhīfēnxīyánjiū
AT chénwēiyǔ jiànlìkāiguǎnshìgùxiāngcuìqǔjīngpiàndāpèigǎnyīngǒuhédiànjiāngzhìpǔyízhīliánxiànfēnxīxìtǒngjìnxínggāoyánjīzhìwēitòuxīyàngpǐnzhōngwēiliàngyuánsùzhīfēnxīyánjiū
_version_ 1718128486664634368