An Analog Front-End Circuit for Bio-signal Measurement System Using Chopper Stabilization Technique
碩士 === 國立中央大學 === 電機工程研究所 === 97 === In recent years, the implanted bio-signal measurement devices for various bio-medical applications tend to be minimized and with wireless transmission capabilities. Since physiological signals from electrodes are very tiny and are difficult to be recorded, design...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2009
|
Online Access: | http://ndltd.ncl.edu.tw/handle/01614219110806480639 |
id |
ndltd-TW-097NCU05442034 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-097NCU054420342016-05-02T04:12:03Z http://ndltd.ncl.edu.tw/handle/01614219110806480639 An Analog Front-End Circuit for Bio-signal Measurement System Using Chopper Stabilization Technique 應用於生理訊號量測系統之截波穩定型類比前端電路 Wei-Chih Lin 林威志 碩士 國立中央大學 電機工程研究所 97 In recent years, the implanted bio-signal measurement devices for various bio-medical applications tend to be minimized and with wireless transmission capabilities. Since physiological signals from electrodes are very tiny and are difficult to be recorded, design of the bio-signal analog-front-end circuits are always with the features of low-noise, high resolution, and low power consumption. This work presents a fully differential and analog-front-end circuit for bio-signal measurement system that can be used to record the very tiny electroneurography (ENG) signals. Chopper stabilization technique (CHS) is employed in the amplification stage to eliminate the non-ideal low-frequency effects, such as the flicker noise and the DC-offset voltage. It improves the signal-to-noise ratio (SNR) and offers a higher resolution for the recorded neuron signals. In order to decrease the power dissipation of the system, input stages of field-effect transistors are designed to be operating at the weak-inversion region. In addition, the band-pass filter of the chopper-stabilized amplifier consists of a differential difference amplifier and a Miller integrator, which are different to the traditional design with passive resistors and capacitors. The purpose of this BPF is aimed to cancel out the DC-offset voltage from the electrode-electrolyte interface. The whole AFE circuit includes a bias circuit, a clock generator, a chopper stabilization amplifier, a post-amplifier, and a second-order continues-time low-pass filter. Such AFE circuit is implemented in the TSMC 0.18-μm one-poly six-metals CMOS process and provides a mid-band gain of 62.9 dB, a signal bandwidth approximates up to 9.3 KHz, a total equivalent input-referred noise of about 7.05 μVrms, and a 10-bit resolution. Supplied at 1.8 V, the proposed AFE circuit consumes around 230 μW. The chip area is 0.88 × 0.43 mm2. Muh-Tian Shiue 薛木添 2009 學位論文 ; thesis 95 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立中央大學 === 電機工程研究所 === 97 === In recent years, the implanted bio-signal measurement devices for various bio-medical applications tend to be minimized and with wireless transmission capabilities. Since physiological signals from electrodes are very tiny and are difficult to be recorded, design of the bio-signal analog-front-end circuits are always with the features of low-noise, high resolution, and low power consumption.
This work presents a fully differential and analog-front-end circuit for bio-signal measurement system that can be used to record the very tiny electroneurography (ENG) signals. Chopper stabilization technique (CHS) is employed in the amplification stage to eliminate the non-ideal low-frequency effects, such as the flicker noise and the DC-offset voltage. It improves the signal-to-noise ratio (SNR) and offers a higher resolution for the recorded neuron signals. In order to decrease the power dissipation of the system, input stages of field-effect transistors are designed to be operating at the weak-inversion region. In addition, the band-pass filter of the chopper-stabilized amplifier consists of a differential difference amplifier and a Miller integrator, which are different to the traditional design with passive resistors and capacitors. The purpose of this BPF is aimed to cancel out the DC-offset voltage from the electrode-electrolyte interface.
The whole AFE circuit includes a bias circuit, a clock generator, a chopper stabilization amplifier, a post-amplifier, and a second-order continues-time low-pass filter. Such AFE circuit is implemented in the TSMC 0.18-μm one-poly six-metals CMOS process and provides a mid-band gain of 62.9 dB, a signal bandwidth approximates up to 9.3 KHz, a total equivalent input-referred noise of about 7.05 μVrms, and a 10-bit resolution. Supplied at 1.8 V, the proposed AFE circuit consumes around 230 μW. The chip area is 0.88 × 0.43 mm2.
|
author2 |
Muh-Tian Shiue |
author_facet |
Muh-Tian Shiue Wei-Chih Lin 林威志 |
author |
Wei-Chih Lin 林威志 |
spellingShingle |
Wei-Chih Lin 林威志 An Analog Front-End Circuit for Bio-signal Measurement System Using Chopper Stabilization Technique |
author_sort |
Wei-Chih Lin |
title |
An Analog Front-End Circuit for Bio-signal Measurement System Using Chopper Stabilization Technique |
title_short |
An Analog Front-End Circuit for Bio-signal Measurement System Using Chopper Stabilization Technique |
title_full |
An Analog Front-End Circuit for Bio-signal Measurement System Using Chopper Stabilization Technique |
title_fullStr |
An Analog Front-End Circuit for Bio-signal Measurement System Using Chopper Stabilization Technique |
title_full_unstemmed |
An Analog Front-End Circuit for Bio-signal Measurement System Using Chopper Stabilization Technique |
title_sort |
analog front-end circuit for bio-signal measurement system using chopper stabilization technique |
publishDate |
2009 |
url |
http://ndltd.ncl.edu.tw/handle/01614219110806480639 |
work_keys_str_mv |
AT weichihlin ananalogfrontendcircuitforbiosignalmeasurementsystemusingchopperstabilizationtechnique AT línwēizhì ananalogfrontendcircuitforbiosignalmeasurementsystemusingchopperstabilizationtechnique AT weichihlin yīngyòngyúshēnglǐxùnhàoliàngcèxìtǒngzhījiébōwěndìngxínglèibǐqiánduāndiànlù AT línwēizhì yīngyòngyúshēnglǐxùnhàoliàngcèxìtǒngzhījiébōwěndìngxínglèibǐqiánduāndiànlù AT weichihlin analogfrontendcircuitforbiosignalmeasurementsystemusingchopperstabilizationtechnique AT línwēizhì analogfrontendcircuitforbiosignalmeasurementsystemusingchopperstabilizationtechnique |
_version_ |
1718254623463047168 |