A Study of Equipment Operation Maintenance and Fault Analysis at High-Voltage Customer Side

碩士 === 崑山科技大學 === 電機工程研究所 === 97 === This thesis presented the systematic arrangement of the electrical equipments maintenance and measurement technique in distribution system. Those jobs involve not only for the measuring of equipments also about the safety of personnel. The measurement method of i...

Full description

Bibliographic Details
Main Authors: Ming-Hua Chiu, 邱明華
Other Authors: Wei-Fu Su
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/6vj24s
id ndltd-TW-097KSUT5442054
record_format oai_dc
spelling ndltd-TW-097KSUT54420542019-05-15T20:33:45Z http://ndltd.ncl.edu.tw/handle/6vj24s A Study of Equipment Operation Maintenance and Fault Analysis at High-Voltage Customer Side 高壓用戶設備運轉檢測及故障分析之研究 Ming-Hua Chiu 邱明華 碩士 崑山科技大學 電機工程研究所 97 This thesis presented the systematic arrangement of the electrical equipments maintenance and measurement technique in distribution system. Those jobs involve not only for the measuring of equipments also about the safety of personnel. The measurement method of insulation resistance in equipments is the simplest that only can confirm rapidly the equipment superficial is clean or not. The measurement method of medium power factor can distinguish most effective of insulation material in all. Also, the measurement method of partial discharge has result of with measuring of equipments. Simultaneously, this thesis also presented the lightning arrester failure to induce the ground fault accident in customer side system. This high-voltage customer is supplied by two feeders at Tainan Science Park. Due to the lightning arrester failure then causes the ground potential rise to burn the head of underground cable that does not use but remove yet. The accident wave forms had been to re-build from the record of digital protection relay. Also, the resistance value of the ground systems was measured after accident. This thesis utilizes the simulation results of the electromagnetic transient program to analyze the reason in accordance with the power system states happened at that time of accident. There are included electric equipment grounding, lightning arrester grounding and systematic interconnection state to make a prevent strategy and offer the countermeasure of improving by promoting the quality of power supply. Wei-Fu Su 蘇偉府 2009 學位論文 ; thesis 94 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 崑山科技大學 === 電機工程研究所 === 97 === This thesis presented the systematic arrangement of the electrical equipments maintenance and measurement technique in distribution system. Those jobs involve not only for the measuring of equipments also about the safety of personnel. The measurement method of insulation resistance in equipments is the simplest that only can confirm rapidly the equipment superficial is clean or not. The measurement method of medium power factor can distinguish most effective of insulation material in all. Also, the measurement method of partial discharge has result of with measuring of equipments. Simultaneously, this thesis also presented the lightning arrester failure to induce the ground fault accident in customer side system. This high-voltage customer is supplied by two feeders at Tainan Science Park. Due to the lightning arrester failure then causes the ground potential rise to burn the head of underground cable that does not use but remove yet. The accident wave forms had been to re-build from the record of digital protection relay. Also, the resistance value of the ground systems was measured after accident. This thesis utilizes the simulation results of the electromagnetic transient program to analyze the reason in accordance with the power system states happened at that time of accident. There are included electric equipment grounding, lightning arrester grounding and systematic interconnection state to make a prevent strategy and offer the countermeasure of improving by promoting the quality of power supply.
author2 Wei-Fu Su
author_facet Wei-Fu Su
Ming-Hua Chiu
邱明華
author Ming-Hua Chiu
邱明華
spellingShingle Ming-Hua Chiu
邱明華
A Study of Equipment Operation Maintenance and Fault Analysis at High-Voltage Customer Side
author_sort Ming-Hua Chiu
title A Study of Equipment Operation Maintenance and Fault Analysis at High-Voltage Customer Side
title_short A Study of Equipment Operation Maintenance and Fault Analysis at High-Voltage Customer Side
title_full A Study of Equipment Operation Maintenance and Fault Analysis at High-Voltage Customer Side
title_fullStr A Study of Equipment Operation Maintenance and Fault Analysis at High-Voltage Customer Side
title_full_unstemmed A Study of Equipment Operation Maintenance and Fault Analysis at High-Voltage Customer Side
title_sort study of equipment operation maintenance and fault analysis at high-voltage customer side
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/6vj24s
work_keys_str_mv AT minghuachiu astudyofequipmentoperationmaintenanceandfaultanalysisathighvoltagecustomerside
AT qiūmínghuá astudyofequipmentoperationmaintenanceandfaultanalysisathighvoltagecustomerside
AT minghuachiu gāoyāyònghùshèbèiyùnzhuǎnjiǎncèjígùzhàngfēnxīzhīyánjiū
AT qiūmínghuá gāoyāyònghùshèbèiyùnzhuǎnjiǎncèjígùzhàngfēnxīzhīyánjiū
AT minghuachiu studyofequipmentoperationmaintenanceandfaultanalysisathighvoltagecustomerside
AT qiūmínghuá studyofequipmentoperationmaintenanceandfaultanalysisathighvoltagecustomerside
_version_ 1719101045082161152