A New Setup for Pulsating Water Jet Lavage Applied on Contaminated Wounds

碩士 === 義守大學 === 機械與自動化工程學系碩士班 === 97 === The research is to develop a miniature pulsating water jet lavage system for the clinical workers to clean patient’s wounds effectively. The system processes 2 distinct characters from the existing systems. (1)The pulsating frequency and pressure are adjustab...

Full description

Bibliographic Details
Main Authors: Fu-Cheng Wu, 吳府承
Other Authors: E-Hsung Cheng
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/51888430257009160796
id ndltd-TW-097ISU05689003
record_format oai_dc
spelling ndltd-TW-097ISU056890032015-10-13T14:52:52Z http://ndltd.ncl.edu.tw/handle/51888430257009160796 A New Setup for Pulsating Water Jet Lavage Applied on Contaminated Wounds 應用於清潔傷口之沖灌系統 Fu-Cheng Wu 吳府承 碩士 義守大學 機械與自動化工程學系碩士班 97 The research is to develop a miniature pulsating water jet lavage system for the clinical workers to clean patient’s wounds effectively. The system processes 2 distinct characters from the existing systems. (1)The pulsating frequency and pressure are adjustable for a better cleaning according to the patient’s wounds. (2) The system are divided into 2 portions. One, containing the pump and nozzle, is disposible after lavage. Another, containing the driving moter and its control, is re-usable. The 2 portions are connected by a coupler while in use. Since the existing lavage systems are designed to be discarded after use, the new system is more cost efficient and environmental friendly. The main part of the motor control is a BS2 microprocessor made by Parallax. It manages the motor-and-pump to produce the desired frequency and pressure. The control program is written in Basic Stamp language. To fit the system th pump is a brand new design. To verify that it can achieve the most effective lavage pressure of 4~15psi, a measuring platform is designed. A pressure gauge is fixed 2 CM from the nozzle horizontally. Water streams from the nozzle will push the gauge. It produces analog signals according to the variation of pressures. Through an A/D conversion circuit and a PCI8255 interface, the pressure data are acquired by a program written in Visual Basic. The experiments prove that the pump can produce enough pressure for every frequency. Finally lavage tests are made with satisfactory results. E-Hsung Cheng 陳一雄 2009 學位論文 ; thesis 80 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 義守大學 === 機械與自動化工程學系碩士班 === 97 === The research is to develop a miniature pulsating water jet lavage system for the clinical workers to clean patient’s wounds effectively. The system processes 2 distinct characters from the existing systems. (1)The pulsating frequency and pressure are adjustable for a better cleaning according to the patient’s wounds. (2) The system are divided into 2 portions. One, containing the pump and nozzle, is disposible after lavage. Another, containing the driving moter and its control, is re-usable. The 2 portions are connected by a coupler while in use. Since the existing lavage systems are designed to be discarded after use, the new system is more cost efficient and environmental friendly. The main part of the motor control is a BS2 microprocessor made by Parallax. It manages the motor-and-pump to produce the desired frequency and pressure. The control program is written in Basic Stamp language. To fit the system th pump is a brand new design. To verify that it can achieve the most effective lavage pressure of 4~15psi, a measuring platform is designed. A pressure gauge is fixed 2 CM from the nozzle horizontally. Water streams from the nozzle will push the gauge. It produces analog signals according to the variation of pressures. Through an A/D conversion circuit and a PCI8255 interface, the pressure data are acquired by a program written in Visual Basic. The experiments prove that the pump can produce enough pressure for every frequency. Finally lavage tests are made with satisfactory results.
author2 E-Hsung Cheng
author_facet E-Hsung Cheng
Fu-Cheng Wu
吳府承
author Fu-Cheng Wu
吳府承
spellingShingle Fu-Cheng Wu
吳府承
A New Setup for Pulsating Water Jet Lavage Applied on Contaminated Wounds
author_sort Fu-Cheng Wu
title A New Setup for Pulsating Water Jet Lavage Applied on Contaminated Wounds
title_short A New Setup for Pulsating Water Jet Lavage Applied on Contaminated Wounds
title_full A New Setup for Pulsating Water Jet Lavage Applied on Contaminated Wounds
title_fullStr A New Setup for Pulsating Water Jet Lavage Applied on Contaminated Wounds
title_full_unstemmed A New Setup for Pulsating Water Jet Lavage Applied on Contaminated Wounds
title_sort new setup for pulsating water jet lavage applied on contaminated wounds
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/51888430257009160796
work_keys_str_mv AT fuchengwu anewsetupforpulsatingwaterjetlavageappliedoncontaminatedwounds
AT wúfǔchéng anewsetupforpulsatingwaterjetlavageappliedoncontaminatedwounds
AT fuchengwu yīngyòngyúqīngjiéshāngkǒuzhīchōngguànxìtǒng
AT wúfǔchéng yīngyòngyúqīngjiéshāngkǒuzhīchōngguànxìtǒng
AT fuchengwu newsetupforpulsatingwaterjetlavageappliedoncontaminatedwounds
AT wúfǔchéng newsetupforpulsatingwaterjetlavageappliedoncontaminatedwounds
_version_ 1717759965323591680