Accuracy Analysis of Measurement System

碩士 === 義守大學 === 工業工程與管理學系碩士班 === 97 === In order to sustainable survival and development, and for quality management system requirements, modern enterprises need to develop and implement discipline, to ensure that the product quality. Recently to participate in the ISO 9000 standard certification, o...

Full description

Bibliographic Details
Main Authors: Hsieh-chin Li, 李協親
Other Authors: Wen-kuei Chen
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/64306025866763337363
id ndltd-TW-097ISU05031010
record_format oai_dc
spelling ndltd-TW-097ISU050310102016-05-04T04:25:29Z http://ndltd.ncl.edu.tw/handle/64306025866763337363 Accuracy Analysis of Measurement System 量測系統準度分析 Hsieh-chin Li 李協親 碩士 義守大學 工業工程與管理學系碩士班 97 In order to sustainable survival and development, and for quality management system requirements, modern enterprises need to develop and implement discipline, to ensure that the product quality. Recently to participate in the ISO 9000 standard certification, or the TS 16949 standard certification, and import the Six Sigma system, the enterprise has been pursuit the international quality criterion of supremacy. As a result of the measurement management is a key element of quality assurance system, modern enterprise should be the measurement system as the focus of inspection item. In1994, the Big Three U.S. automakers first jointly promulgated the QS 9000 standard, formally the Measurement System Analysis as a mandatory item. For in accordance to the ISO 9000:2000 standard, the Big Three U.S. automakers require the quality management system of suppliers will be fully converted to the TS 16949 standard since 2006. However, the MSA is still the requirements item of the system mandatory. As the North American Automotive Industry jointly request the use of MSA has more than 10 years, lead the industry general will be the MSA of the TS 16949 standard as the requirements item of quality management system. The MSA is based on the stability of system performance, and the main content of system performance contains precision and accuracy. The precision evaluation on the MSA, the method of various industries to adopt are similar; but,the accuracy evaluation method of adopted by various industries, it is no different, and many are troubled fallacy. This study investigated the accuracy evaluation method of various industries, including the method of the TS 16949 standard, MINITAB Package and the U.S. Intel Corporation, and exposes their fallacy. Starting from the bivariate normal distribution, this study to build the statistical model of MSA; then, according to the model can master the variation relations between parts value, measured value and appraiser bias. Final, for the accuracy evaluation fallacy of various industries, this study advance the improved methods of meet the needs of various industries; And, this study development the software model of accuracy evaluation, to support the business users. Wen-kuei Chen 陳文魁 2009 學位論文 ; thesis 81 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 義守大學 === 工業工程與管理學系碩士班 === 97 === In order to sustainable survival and development, and for quality management system requirements, modern enterprises need to develop and implement discipline, to ensure that the product quality. Recently to participate in the ISO 9000 standard certification, or the TS 16949 standard certification, and import the Six Sigma system, the enterprise has been pursuit the international quality criterion of supremacy. As a result of the measurement management is a key element of quality assurance system, modern enterprise should be the measurement system as the focus of inspection item. In1994, the Big Three U.S. automakers first jointly promulgated the QS 9000 standard, formally the Measurement System Analysis as a mandatory item. For in accordance to the ISO 9000:2000 standard, the Big Three U.S. automakers require the quality management system of suppliers will be fully converted to the TS 16949 standard since 2006. However, the MSA is still the requirements item of the system mandatory. As the North American Automotive Industry jointly request the use of MSA has more than 10 years, lead the industry general will be the MSA of the TS 16949 standard as the requirements item of quality management system. The MSA is based on the stability of system performance, and the main content of system performance contains precision and accuracy. The precision evaluation on the MSA, the method of various industries to adopt are similar; but,the accuracy evaluation method of adopted by various industries, it is no different, and many are troubled fallacy. This study investigated the accuracy evaluation method of various industries, including the method of the TS 16949 standard, MINITAB Package and the U.S. Intel Corporation, and exposes their fallacy. Starting from the bivariate normal distribution, this study to build the statistical model of MSA; then, according to the model can master the variation relations between parts value, measured value and appraiser bias. Final, for the accuracy evaluation fallacy of various industries, this study advance the improved methods of meet the needs of various industries; And, this study development the software model of accuracy evaluation, to support the business users.
author2 Wen-kuei Chen
author_facet Wen-kuei Chen
Hsieh-chin Li
李協親
author Hsieh-chin Li
李協親
spellingShingle Hsieh-chin Li
李協親
Accuracy Analysis of Measurement System
author_sort Hsieh-chin Li
title Accuracy Analysis of Measurement System
title_short Accuracy Analysis of Measurement System
title_full Accuracy Analysis of Measurement System
title_fullStr Accuracy Analysis of Measurement System
title_full_unstemmed Accuracy Analysis of Measurement System
title_sort accuracy analysis of measurement system
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/64306025866763337363
work_keys_str_mv AT hsiehchinli accuracyanalysisofmeasurementsystem
AT lǐxiéqīn accuracyanalysisofmeasurementsystem
AT hsiehchinli liàngcèxìtǒngzhǔndùfēnxī
AT lǐxiéqīn liàngcèxìtǒngzhǔndùfēnxī
_version_ 1718256963434840064