Simultaneous direct quantification of urinary 8-oxodGuo and 8-oxoGua using on-line SPE LC-MS/MS method

碩士 === 中山醫學大學 === 公共衛生學系碩士班 === 97 === A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with an on-line solid-phase extraction (SPE) system was developed to simultaneously determine 8-oxo-7,8-dihydroguanine (8-oxoGua) and 8-oxo-7, 8-dihydro-2’-deoxyguanosine...

Full description

Bibliographic Details
Main Authors: Ciao-Han, 謝樵漢
Other Authors: 胡瓊文
Format: Others
Language:zh-TW
Published: 2009
Online Access:http://ndltd.ncl.edu.tw/handle/35733288974066935507
id ndltd-TW-097CSMU5058007
record_format oai_dc
spelling ndltd-TW-097CSMU50580072015-10-28T04:07:06Z http://ndltd.ncl.edu.tw/handle/35733288974066935507 Simultaneous direct quantification of urinary 8-oxodGuo and 8-oxoGua using on-line SPE LC-MS/MS method 運用連線固相萃取搭配液相層析串聯質譜儀同時分析尿液中 8-oxo-7,8-dihydro-2''-deoxyguanosine 與 8-oxo-7,8-dihydroguanine Ciao-Han 謝樵漢 碩士 中山醫學大學 公共衛生學系碩士班 97 A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with an on-line solid-phase extraction (SPE) system was developed to simultaneously determine 8-oxo-7,8-dihydroguanine (8-oxoGua) and 8-oxo-7, 8-dihydro-2’-deoxyguanosine (8-oxodGuo) in urine. 15N5-labeled 8-oxoGua was also successfully synthesized to serve as an internal standard in this method. After spiking internal standard, the urine sample can be directly analyzed within 15 min without further sample purification. With this newly developed method, we further investigated the stability of 8-oxoGua under several common storage conditions. The results showed that the stability of 8-oxoGua was affected by pH, temperature and its initial concentration. It was found that the high concentration of 8-oxoGua (10 μg/mL) was the most stable at 4°C with pH value ≤ 11 (the half-life was estimated to be around 105 days), while it was the less stable at -20°C with pH value of 12 (the half-life was estimated to be 4 days). On the other hand, the low concentration of 8-oxoGua (50 ng/mL) had the best stability at -20°C with pH value < 8 (half-life: 578 days), and the worst stability at -20°C with pH value of 12 (half-life: 4 days). Meanwhile, this “on-line SPE LC-MS/MS” method was also applied to determine the background levels of 8-oxoGua/8-oxodGuo in urine of healthy adults. The urinary levels of 8-oxoGua and 8-oxodGuo were 5.95 ± 5.20 and 1.74 ± 0.84 (nmol/mmol creatinine), respectively. The ratio of 8-oxoGua and 8-oxodGuo levels in urine was around 3.41. This “on-line SPE LC-MS/MS” method could be applicable for use in daily clinical practice for assessing oxidative stress in patients. 胡瓊文 2009 學位論文 ; thesis 70 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中山醫學大學 === 公共衛生學系碩士班 === 97 === A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with an on-line solid-phase extraction (SPE) system was developed to simultaneously determine 8-oxo-7,8-dihydroguanine (8-oxoGua) and 8-oxo-7, 8-dihydro-2’-deoxyguanosine (8-oxodGuo) in urine. 15N5-labeled 8-oxoGua was also successfully synthesized to serve as an internal standard in this method. After spiking internal standard, the urine sample can be directly analyzed within 15 min without further sample purification. With this newly developed method, we further investigated the stability of 8-oxoGua under several common storage conditions. The results showed that the stability of 8-oxoGua was affected by pH, temperature and its initial concentration. It was found that the high concentration of 8-oxoGua (10 μg/mL) was the most stable at 4°C with pH value ≤ 11 (the half-life was estimated to be around 105 days), while it was the less stable at -20°C with pH value of 12 (the half-life was estimated to be 4 days). On the other hand, the low concentration of 8-oxoGua (50 ng/mL) had the best stability at -20°C with pH value < 8 (half-life: 578 days), and the worst stability at -20°C with pH value of 12 (half-life: 4 days). Meanwhile, this “on-line SPE LC-MS/MS” method was also applied to determine the background levels of 8-oxoGua/8-oxodGuo in urine of healthy adults. The urinary levels of 8-oxoGua and 8-oxodGuo were 5.95 ± 5.20 and 1.74 ± 0.84 (nmol/mmol creatinine), respectively. The ratio of 8-oxoGua and 8-oxodGuo levels in urine was around 3.41. This “on-line SPE LC-MS/MS” method could be applicable for use in daily clinical practice for assessing oxidative stress in patients.
author2 胡瓊文
author_facet 胡瓊文
Ciao-Han
謝樵漢
author Ciao-Han
謝樵漢
spellingShingle Ciao-Han
謝樵漢
Simultaneous direct quantification of urinary 8-oxodGuo and 8-oxoGua using on-line SPE LC-MS/MS method
author_sort Ciao-Han
title Simultaneous direct quantification of urinary 8-oxodGuo and 8-oxoGua using on-line SPE LC-MS/MS method
title_short Simultaneous direct quantification of urinary 8-oxodGuo and 8-oxoGua using on-line SPE LC-MS/MS method
title_full Simultaneous direct quantification of urinary 8-oxodGuo and 8-oxoGua using on-line SPE LC-MS/MS method
title_fullStr Simultaneous direct quantification of urinary 8-oxodGuo and 8-oxoGua using on-line SPE LC-MS/MS method
title_full_unstemmed Simultaneous direct quantification of urinary 8-oxodGuo and 8-oxoGua using on-line SPE LC-MS/MS method
title_sort simultaneous direct quantification of urinary 8-oxodguo and 8-oxogua using on-line spe lc-ms/ms method
publishDate 2009
url http://ndltd.ncl.edu.tw/handle/35733288974066935507
work_keys_str_mv AT ciaohan simultaneousdirectquantificationofurinary8oxodguoand8oxoguausingonlinespelcmsmsmethod
AT xièqiáohàn simultaneousdirectquantificationofurinary8oxodguoand8oxoguausingonlinespelcmsmsmethod
AT ciaohan yùnyòngliánxiàngùxiāngcuìqǔdāpèiyèxiāngcéngxīchuànliánzhìpǔyítóngshífēnxīniàoyèzhōng8oxo78dihydro2aposaposdeoxyguanosineyǔ8oxo78dihydroguanine
AT xièqiáohàn yùnyòngliánxiàngùxiāngcuìqǔdāpèiyèxiāngcéngxīchuànliánzhìpǔyítóngshífēnxīniàoyèzhōng8oxo78dihydro2aposaposdeoxyguanosineyǔ8oxo78dihydroguanine
_version_ 1718112431433056256