The Efficiency Analysis of Cooling Degree Day in Building

碩士 === 國立臺北科技大學 === 冷凍與低溫科技研究所 === 96 === Benchmarking the energy efficiency for cooling degree day in buildings is an important tool to promote the efficient use of energy. This paper develops a benchmarking process for energy efficiency for cooling purposes by means of data envelopment analysis an...

Full description

Bibliographic Details
Main Authors: Chun-Cheng Huang, 黃鈞政
Other Authors: 李文興
Format: Others
Language:zh-TW
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/6d78hg
id ndltd-TW-096TIT05703018
record_format oai_dc
spelling ndltd-TW-096TIT057030182019-07-25T04:46:33Z http://ndltd.ncl.edu.tw/handle/6d78hg The Efficiency Analysis of Cooling Degree Day in Building 冷房度日對建築物能源效率之影響分析 Chun-Cheng Huang 黃鈞政 碩士 國立臺北科技大學 冷凍與低溫科技研究所 96 Benchmarking the energy efficiency for cooling degree day in buildings is an important tool to promote the efficient use of energy. This paper develops a benchmarking process for energy efficiency for cooling purposes by means of data envelopment analysis and cooling degree hour method. The research begins by using climate data to calculate cooling degree hour and proceeds to build an index of total performance of energy for cooling purposes by linear regression method using energy consumption of building as dependent variable and cooling degree hour as independent variable. Finally, using data envelopment analysis, this study benchmarks the energy efficiency for cooling purposes in buildings with the index of total performance of energy for cooling by removing the effect of building scale factors, such as floor area and number of occupants. An application to office buildings in Taiwan is presented to illustrate the development and the use of the evaluating method. 李文興 2008 學位論文 ; thesis 52 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 冷凍與低溫科技研究所 === 96 === Benchmarking the energy efficiency for cooling degree day in buildings is an important tool to promote the efficient use of energy. This paper develops a benchmarking process for energy efficiency for cooling purposes by means of data envelopment analysis and cooling degree hour method. The research begins by using climate data to calculate cooling degree hour and proceeds to build an index of total performance of energy for cooling purposes by linear regression method using energy consumption of building as dependent variable and cooling degree hour as independent variable. Finally, using data envelopment analysis, this study benchmarks the energy efficiency for cooling purposes in buildings with the index of total performance of energy for cooling by removing the effect of building scale factors, such as floor area and number of occupants. An application to office buildings in Taiwan is presented to illustrate the development and the use of the evaluating method.
author2 李文興
author_facet 李文興
Chun-Cheng Huang
黃鈞政
author Chun-Cheng Huang
黃鈞政
spellingShingle Chun-Cheng Huang
黃鈞政
The Efficiency Analysis of Cooling Degree Day in Building
author_sort Chun-Cheng Huang
title The Efficiency Analysis of Cooling Degree Day in Building
title_short The Efficiency Analysis of Cooling Degree Day in Building
title_full The Efficiency Analysis of Cooling Degree Day in Building
title_fullStr The Efficiency Analysis of Cooling Degree Day in Building
title_full_unstemmed The Efficiency Analysis of Cooling Degree Day in Building
title_sort efficiency analysis of cooling degree day in building
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/6d78hg
work_keys_str_mv AT chunchenghuang theefficiencyanalysisofcoolingdegreedayinbuilding
AT huángjūnzhèng theefficiencyanalysisofcoolingdegreedayinbuilding
AT chunchenghuang lěngfángdùrìduìjiànzhúwùnéngyuánxiàolǜzhīyǐngxiǎngfēnxī
AT huángjūnzhèng lěngfángdùrìduìjiànzhúwùnéngyuánxiàolǜzhīyǐngxiǎngfēnxī
AT chunchenghuang efficiencyanalysisofcoolingdegreedayinbuilding
AT huángjūnzhèng efficiencyanalysisofcoolingdegreedayinbuilding
_version_ 1719229756625387520