Apply LED To Medical Diagnosis Lamp Design Develop And Theraml System Identification

碩士 === 國立臺北科技大學 === 製造科技研究所 === 96 === This thesis maimly aim at developing the medical diagnosis lamp with LED,we consider that the medical diagnosis should decrease infected probability when using.All system is designed by fastening and locking for cooperating.Such a design is not only easy to dis...

Full description

Bibliographic Details
Main Authors: Yu-Tsung Hsieh, 謝毓聰
Other Authors: 王金樹
Format: Others
Language:zh-TW
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/a5rdx8
id ndltd-TW-096TIT05621033
record_format oai_dc
spelling ndltd-TW-096TIT056210332019-07-24T03:39:12Z http://ndltd.ncl.edu.tw/handle/a5rdx8 Apply LED To Medical Diagnosis Lamp Design Develop And Theraml System Identification LED應用於醫療診斷燈之設計開發與散熱系統識別 Yu-Tsung Hsieh 謝毓聰 碩士 國立臺北科技大學 製造科技研究所 96 This thesis maimly aim at developing the medical diagnosis lamp with LED,we consider that the medical diagnosis should decrease infected probability when using.All system is designed by fastening and locking for cooperating.Such a design is not only easy to dismantle but also easy to clean, it is reusable and replaceable.We use the system identification to find the transfer function for simulating the safe operating temperature when developing.The simulate error is within 0.5%,the Max. temperature is 1.7℃,the relative error temperature is 0.0119℃, relative error percent is 0.337%.And the Medical diagnosis lamp lowest total thermal resistance is 1.11℃/W,lowest internal thermal resistance is 1.0564℃/W, owest extrnal thermal resistance is 0.0564℃/W.The chip temperature is controlled between 67℃ and 72.1℃.It has reached the goal that control chip temperature under 100℃.We also design a Variable Light Mechanism,form the experimental result show that the MAX. illumination is 1109lux, the MIN. illumination is 791lux. 王金樹 林水泉 2008 學位論文 ; thesis 90 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 製造科技研究所 === 96 === This thesis maimly aim at developing the medical diagnosis lamp with LED,we consider that the medical diagnosis should decrease infected probability when using.All system is designed by fastening and locking for cooperating.Such a design is not only easy to dismantle but also easy to clean, it is reusable and replaceable.We use the system identification to find the transfer function for simulating the safe operating temperature when developing.The simulate error is within 0.5%,the Max. temperature is 1.7℃,the relative error temperature is 0.0119℃, relative error percent is 0.337%.And the Medical diagnosis lamp lowest total thermal resistance is 1.11℃/W,lowest internal thermal resistance is 1.0564℃/W, owest extrnal thermal resistance is 0.0564℃/W.The chip temperature is controlled between 67℃ and 72.1℃.It has reached the goal that control chip temperature under 100℃.We also design a Variable Light Mechanism,form the experimental result show that the MAX. illumination is 1109lux, the MIN. illumination is 791lux.
author2 王金樹
author_facet 王金樹
Yu-Tsung Hsieh
謝毓聰
author Yu-Tsung Hsieh
謝毓聰
spellingShingle Yu-Tsung Hsieh
謝毓聰
Apply LED To Medical Diagnosis Lamp Design Develop And Theraml System Identification
author_sort Yu-Tsung Hsieh
title Apply LED To Medical Diagnosis Lamp Design Develop And Theraml System Identification
title_short Apply LED To Medical Diagnosis Lamp Design Develop And Theraml System Identification
title_full Apply LED To Medical Diagnosis Lamp Design Develop And Theraml System Identification
title_fullStr Apply LED To Medical Diagnosis Lamp Design Develop And Theraml System Identification
title_full_unstemmed Apply LED To Medical Diagnosis Lamp Design Develop And Theraml System Identification
title_sort apply led to medical diagnosis lamp design develop and theraml system identification
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/a5rdx8
work_keys_str_mv AT yutsunghsieh applyledtomedicaldiagnosislampdesigndevelopandtheramlsystemidentification
AT xièyùcōng applyledtomedicaldiagnosislampdesigndevelopandtheramlsystemidentification
AT yutsunghsieh ledyīngyòngyúyīliáozhěnduàndēngzhīshèjìkāifāyǔsànrèxìtǒngshíbié
AT xièyùcōng ledyīngyòngyúyīliáozhěnduàndēngzhīshèjìkāifāyǔsànrèxìtǒngshíbié
_version_ 1719229652197703680