Analysis of the flow field behind backward-facing step with wall of vertical mass injection and different sudden expansion ratio

碩士 === 國立臺北科技大學 === 車輛工程系所 === 96 === This study use the CFD-RC(Computation Fluid Dynamics Research Corporation) software to analyze the turbulent flow field behind a backward-facing step with of vertical wall mass bleed. The effect of sudden expansion ratio also included in this work. By changing t...

Full description

Bibliographic Details
Main Authors: Yi-Jong Chen, 陳奕仲
Other Authors: 蔡國隆
Format: Others
Language:zh-TW
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/tks3dz
id ndltd-TW-096TIT05162047
record_format oai_dc
spelling ndltd-TW-096TIT051620472019-07-25T04:46:39Z http://ndltd.ncl.edu.tw/handle/tks3dz Analysis of the flow field behind backward-facing step with wall of vertical mass injection and different sudden expansion ratio 具壁面垂直噴流與不同突張比之背向階梯流場分析 Yi-Jong Chen 陳奕仲 碩士 國立臺北科技大學 車輛工程系所 96 This study use the CFD-RC(Computation Fluid Dynamics Research Corporation) software to analyze the turbulent flow field behind a backward-facing step with of vertical wall mass bleed. The effect of sudden expansion ratio also included in this work. By changing the step heights, inlet flow rates and vertical mass injection rates, the corresponded reattachment points and recirculation regions were found and discussed. Using the previous reference works as a basic platform, then this work proceeds different parameter settings for further discussion. According to the analysis of the flow, the result shows that the reattachment length will increase with the increasing of the height of backward-facing step, inlet velocity and vertical mass injection, but the position of the reattachment point almost unchanged as the inlet Re is greater than 10000. The dependence of the three parameters influencing the position of the reattachment point is of the order as step height > inlet velocity > vertical mass injection. The vertical position of maximum turbulence intensity move toward the wall as the axial distance from the step increases, then it move apart from the wall as the axial distance is behind the reattachment point. The turbulence intensity in the recirculation zone is reduced as the vertical mass bleed increases. As the ratio of sudden expansion is 2, the reattachment point nearly exceeds the region of vertical mass bleed, and the flow field influenced by the vertical mass injection mainly locates in the range from 0.86 to 0.98 . 蔡國隆 2008 學位論文 ; thesis 69 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 車輛工程系所 === 96 === This study use the CFD-RC(Computation Fluid Dynamics Research Corporation) software to analyze the turbulent flow field behind a backward-facing step with of vertical wall mass bleed. The effect of sudden expansion ratio also included in this work. By changing the step heights, inlet flow rates and vertical mass injection rates, the corresponded reattachment points and recirculation regions were found and discussed. Using the previous reference works as a basic platform, then this work proceeds different parameter settings for further discussion. According to the analysis of the flow, the result shows that the reattachment length will increase with the increasing of the height of backward-facing step, inlet velocity and vertical mass injection, but the position of the reattachment point almost unchanged as the inlet Re is greater than 10000. The dependence of the three parameters influencing the position of the reattachment point is of the order as step height > inlet velocity > vertical mass injection. The vertical position of maximum turbulence intensity move toward the wall as the axial distance from the step increases, then it move apart from the wall as the axial distance is behind the reattachment point. The turbulence intensity in the recirculation zone is reduced as the vertical mass bleed increases. As the ratio of sudden expansion is 2, the reattachment point nearly exceeds the region of vertical mass bleed, and the flow field influenced by the vertical mass injection mainly locates in the range from 0.86 to 0.98 .
author2 蔡國隆
author_facet 蔡國隆
Yi-Jong Chen
陳奕仲
author Yi-Jong Chen
陳奕仲
spellingShingle Yi-Jong Chen
陳奕仲
Analysis of the flow field behind backward-facing step with wall of vertical mass injection and different sudden expansion ratio
author_sort Yi-Jong Chen
title Analysis of the flow field behind backward-facing step with wall of vertical mass injection and different sudden expansion ratio
title_short Analysis of the flow field behind backward-facing step with wall of vertical mass injection and different sudden expansion ratio
title_full Analysis of the flow field behind backward-facing step with wall of vertical mass injection and different sudden expansion ratio
title_fullStr Analysis of the flow field behind backward-facing step with wall of vertical mass injection and different sudden expansion ratio
title_full_unstemmed Analysis of the flow field behind backward-facing step with wall of vertical mass injection and different sudden expansion ratio
title_sort analysis of the flow field behind backward-facing step with wall of vertical mass injection and different sudden expansion ratio
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/tks3dz
work_keys_str_mv AT yijongchen analysisoftheflowfieldbehindbackwardfacingstepwithwallofverticalmassinjectionanddifferentsuddenexpansionratio
AT chényìzhòng analysisoftheflowfieldbehindbackwardfacingstepwithwallofverticalmassinjectionanddifferentsuddenexpansionratio
AT yijongchen jùbìmiànchuízhípēnliúyǔbùtóngtūzhāngbǐzhībèixiàngjiētīliúchǎngfēnxī
AT chényìzhòng jùbìmiànchuízhípēnliúyǔbùtóngtūzhāngbǐzhībèixiàngjiētīliúchǎngfēnxī
_version_ 1719229588025901056