Design of Viscous Dampers Considering Flexibility of Connecting Braces (Ⅱ)

碩士 === 國立臺灣科技大學 === 營建工程系 === 96 === In the current design practice, the design of viscous dampers to be added to building structures has been following the design formulas provided by FEMA specifications and MCEER reports based on a target damping ratio to be added to the structures. However, in co...

Full description

Bibliographic Details
Main Authors: Yen-Chang Kuo, 郭彥彰
Other Authors: Jenn-Shin Hwang
Format: Others
Language:zh-TW
Published: 2008
Online Access:http://ndltd.ncl.edu.tw/handle/18328920427481356932
id ndltd-TW-096NTUS5512017
record_format oai_dc
spelling ndltd-TW-096NTUS55120172016-05-13T04:15:15Z http://ndltd.ncl.edu.tw/handle/18328920427481356932 Design of Viscous Dampers Considering Flexibility of Connecting Braces (Ⅱ) 考慮銜接斜撐柔度之黏性阻尼器減震設計(Ⅱ) Yen-Chang Kuo 郭彥彰 碩士 國立臺灣科技大學 營建工程系 96 In the current design practice, the design of viscous dampers to be added to building structures has been following the design formulas provided by FEMA specifications and MCEER reports based on a target damping ratio to be added to the structures. However, in construction, the viscous dampers are often connected with braces which may possess some flexibility such that the subsystem composed of a viscous damper and a connecting brace reveals a visco-elastic rather than viscous behavior. As a consequence, the desired target damping ratio may not be achieved. In the analytical work of design process, if the connecting brace is assumed to be rigid, the added damping ratio will certainly be smaller that what is expected in the design. According to a previous study, it was then proposed by Kasai et al. to require the stiffness of the connecting braces has to be at least 5 times the lateral stiffness of the story where the dampers are to be installed. However, this requirement may result into unreasonably large braces that are not acceptable in practical construction. Therefore, it is one of the purposes of the study to derive a design formula that takes the flexibility of the connecting brace into account when deriving the equivalent damping ratio of the structure with added viscous dampers so that the appropriate damping coefficients of viscous dampers can be determined based on the desired target damping ratio. In addition, numerical study has concluded that if the stiffness of the connecting braces is too small the desired design damping ratio cannot be achieved no matter how much damping coefficient of the viscous dampers has be added to the structure. This is particularly true while the desired added damping ratio is larger, e.g. larger than 15%. Jenn-Shin Hwang 黃震興 2008 學位論文 ; thesis 204 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 營建工程系 === 96 === In the current design practice, the design of viscous dampers to be added to building structures has been following the design formulas provided by FEMA specifications and MCEER reports based on a target damping ratio to be added to the structures. However, in construction, the viscous dampers are often connected with braces which may possess some flexibility such that the subsystem composed of a viscous damper and a connecting brace reveals a visco-elastic rather than viscous behavior. As a consequence, the desired target damping ratio may not be achieved. In the analytical work of design process, if the connecting brace is assumed to be rigid, the added damping ratio will certainly be smaller that what is expected in the design. According to a previous study, it was then proposed by Kasai et al. to require the stiffness of the connecting braces has to be at least 5 times the lateral stiffness of the story where the dampers are to be installed. However, this requirement may result into unreasonably large braces that are not acceptable in practical construction. Therefore, it is one of the purposes of the study to derive a design formula that takes the flexibility of the connecting brace into account when deriving the equivalent damping ratio of the structure with added viscous dampers so that the appropriate damping coefficients of viscous dampers can be determined based on the desired target damping ratio. In addition, numerical study has concluded that if the stiffness of the connecting braces is too small the desired design damping ratio cannot be achieved no matter how much damping coefficient of the viscous dampers has be added to the structure. This is particularly true while the desired added damping ratio is larger, e.g. larger than 15%.
author2 Jenn-Shin Hwang
author_facet Jenn-Shin Hwang
Yen-Chang Kuo
郭彥彰
author Yen-Chang Kuo
郭彥彰
spellingShingle Yen-Chang Kuo
郭彥彰
Design of Viscous Dampers Considering Flexibility of Connecting Braces (Ⅱ)
author_sort Yen-Chang Kuo
title Design of Viscous Dampers Considering Flexibility of Connecting Braces (Ⅱ)
title_short Design of Viscous Dampers Considering Flexibility of Connecting Braces (Ⅱ)
title_full Design of Viscous Dampers Considering Flexibility of Connecting Braces (Ⅱ)
title_fullStr Design of Viscous Dampers Considering Flexibility of Connecting Braces (Ⅱ)
title_full_unstemmed Design of Viscous Dampers Considering Flexibility of Connecting Braces (Ⅱ)
title_sort design of viscous dampers considering flexibility of connecting braces (ⅱ)
publishDate 2008
url http://ndltd.ncl.edu.tw/handle/18328920427481356932
work_keys_str_mv AT yenchangkuo designofviscousdampersconsideringflexibilityofconnectingbracesii
AT guōyànzhāng designofviscousdampersconsideringflexibilityofconnectingbracesii
AT yenchangkuo kǎolǜxiánjiēxiéchēngróudùzhīniánxìngzǔníqìjiǎnzhènshèjìii
AT guōyànzhāng kǎolǜxiánjiēxiéchēngróudùzhīniánxìngzǔníqìjiǎnzhènshèjìii
_version_ 1718267804102164480